| Plan Review Stops For Permit 15070555 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2015-09-22 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-22 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-22 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2015-09-22 08:57:27 | ONCE AGAIN I RECEIVED AN INCOMPLETE SUBMITTAL FOR THE | | | ELECTRIC. IN GOING THROUGH THE HISTORY I NOTICED THAT | | | DH HAD PREVIOUSLY APPROVED THIS UNDER A SEPARATE | | | PPERMIT. I RESEARCHED THAT PERMIT TO FIND IT IS THE | | | ELECTRICAL PERMIT FOR THIS SAME INSTALLATION THEREFORE | | | EN ELECTRICAL REVIEW AND SUBSEQUENT DENIAL ON THIS | | | PERMIT IS NOT WARRANTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-08-24 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2015-08-24 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2015-08-24 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2015-08-24 15:29:09 | REVIEWED UNDER 15080577 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-08-10 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-08-10 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2015-08-10 17:59:22 | YOU SHALL PROVIDE AN ELECTRICAL PAGE COMPLYING WITH ALL | | | THE REQUIREMENTS OF SECTION 440 OF THE 2011 EDITION OF | | | THE NEC. THIS SHEET SHALL INCLUDE LOAD CALCULATIONS AND | | | WIRING DETAIL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-09-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-09-22 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-17 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2015-09-22 09:16:01 | 9/22/15 - ELECTRICAL REVIEW WAS PASSED UNDER SEPARATE | | | PERMIT (15080577). CONTRACTOR NOTIFIED VIA EMAIL. SENT | | | TO SMALL DENIED BIN "H". MA | | 2015-09-17 13:49:09 | ROUTED TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-08-26 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-08-25 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2015-08-25 10:45:04 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-08-10 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-08-10 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-07-14 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2015-08-10 18:03:29 | 8/10/15 - FAILED ELECTRICAL REVIEW AS NOTED. CONTRACTOR | | | NOTIFIED VIA EMAIL. SENT TO SMALL DENIED BIN "H". MA | | 2015-07-14 16:13:46 | MECH BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-09-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-09-22 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-09-21 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2015-09-21 10:07:04 | MECHANICAL PROVISO | | | PERMIT #15070555 | | | 09/21/15 | | | | | | SITE SPECIFIC WIND LOAD ENGINEERING FOR TIE DOWN OF THE | | | CONDENSER UNIT SHALL BE ON-SITE AT TIME OF INSPECTION- | | | SECTION 301.15 FBC-14 MECHANICAL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-08-26 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-08-26 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2015-08-26 12:34:41 | 2ND REVIEW: FBC 2014 MECHANICAL | | | | | | 1) PLEASE PROVIDE THE SENSIBLE COOLING CAPACITY OF THE | | | LIEBERT SYSTEM ON THE AC SCHEDULE IN ORDER FOR THE SCOP | | | TO BE VERIFED- REFER TO TABLE C403.2.3(10) FBC-14 | | | ENERGY CONSERVATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-07-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-07-17 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-07-17 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2015-07-17 16:10:05 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15070555 | | | | | | 1) PROVIDE COOLING AND HEATING LOAD CALCULATIONS FOR | | | THE NEW AC SYSTEM IN ACCORDANCE WITH ACCA MANUAL N OR | | | THE ACCA/ASHRAE STANDARD 183- SECTION C403.2.1 FBC | | | FIFTH EDITION 2014 ENERGY CONSERVATION CODE. | | | 2) DUCT SMOKE DETECTORS SHALL BE INSTALLED IN THE | | | RETURN DUCT OF THE NEW AHU, AND THE RETURN DUCTS OF THE | | | EXISTING AHU'S- REFER TO SECTIONS 606.2.1 & 606.2.2 | | | FBC- 2014 MECHANICAL. SHOW THE LOCATIONS OF THE DEVICES | | | ON THE PLANS AND INDICATE HOW THEY WILL BE SUPERVISED | | | PER SECTION 606.4.1. | | | 3) INDICATE THE TYPE AND DIAMETER OF THE CONDENSATE | | | PIPE PER TABLE 307.2.2, AND PROVIDE DETAILS FOR | | | SECONDARY DISPOSAL: A) PAN DIMENSIONS, DEPTH, AND GAGE | | | OF STEEL. B) TYPE AND SIZE OF PAN DRAIN PIPE AND | | | TERMINATION LOCATION- REFER TO SECTION 307.2.3 FOR | | | ADDITIONAL INFORMATION. | | | 4) THE SCOPE OF WORK NOTE #1 ON THE CONTRACT INDICATES | | | A 12X24 FT. MOUNTING PAD FOR THE CONDENSER, HOWEVER THE | | | PLAN INDICATES A 4X34 FT. PAD: PLEASE CLARIFY AND | | | PROVIDE STRUCTURAL DETAILS FOR THE PAD, AND WIND LOAD | | | TIE DOWN ENGINEERING FOR MOUNTING THE CONDENSER TO THE | | | PAD. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-09-17 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-09-17 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-09-17 |
Time |
14:44 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-07-21 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-07-21 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-07-21 |
Time |
11:24 |
Sent To |
E |
|
| Notes |
|
|