Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-10-14 Cont ID  
Sent By jgomez Date 2015-10-14 Time 11:22 Rev Time 0.00
Received By jgomez Date 2015-10-14 Time 11:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-10-02 Cont ID  
Sent By jgomez Date 2015-10-02 Time 10:56 Rev Time 0.00
Received By jgomez Date 2015-10-02 Time 10:56 Sent To  
Notes
2015-10-02 11:03:11 
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-11 Cont ID  
Sent By jgomez Date 2015-09-11 Time 16:50 Rev Time 0.00
Received By jgomez Date 2015-09-11 Time 15:13 Sent To  
Notes
2015-09-11 17:24:09RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW
 COMMENTS.
 CODE: FBC-5TH EDITION (2014).
  
 1- ENERGY CALCULATIONS:
 NOTE: COORDINATE THE ENERGY CALCULATIONS WITH THE FLOOR
 PLANS TO AVOID CONFLICTS OR DELAYS.
  
 A) PROVIDE CURRENT ENERGY CALCULATIONS FORM THAT
 CORRESPOND TO THE 2014 FBC. CALCULATIONS SUBMITTED ARE
 FOR 2010 CODE VERSION. SEC. 1106 OF FBC -EXISTING
 BUILDING, 5TH EDITION (2014).
  
 B) OWNER/AGENT TO CERTIFY AT THE BOTTOM OF THE FORM AS
 REQUIRED BY SEC. R103.1.1.2 OF FBC -EXISTING BUILDING,
 5TH EDITION (2014).
  
 C) COMPLETE ALL THE INFORMATION ON TOP OF FORM,
 INCLUDING THE BUILDER'S NAME.
  
 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  
 3- SPECIFY CARBON MONOXIDE ALARMS WITHIN ALL BEDROOMS
 AS REQUIRED BY SEC. R315 OF FBC-RESIDENTIAL, 5TH
 EDITION (2014).
  
 4- SHEET A1.0:
 A) REVISE DOOR AND WINDOW NOTE: #7. SEE SEC. R612.7.2.1
 OF FBC-RESIDENTIAL, 5TH EDITION (2014) AND WINDOWS AND
 DOORS PRODUCT APPROVALS.
  
 B) REVISE WALL SCHEDULE. COORDINATE INSULATION WITH THE
 ENERGY CALCULATIONS. SEC. R103.2 OF FBC-RESIDENTIAL,
 5TH EDITION (2014).
  
 C) WINDOWS AND DOORS DETAILS. PROVIDE SPECIFICATIONS
 FOR THE 1/4" X 3" X 4" STEEL ANGLE ATTACHMENT. "ATTACH
 PER PRODUCT APPROVAL" IS NOT ENOUGH INFORMATION . THERE
 IS NOT PRODUCT APPROVAL FOR STEEL ANGLES. SEC. R301.1
 OF FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 D) PROVIDE DETAILS/SPECIFICATIONS FOR THE ATTACHMENT OF
 THE BRICK VENEER. SEC. R703.7 OF FBC-RESIDENTIAL, 5TH
 EDITION (2014).
  
 E) PROVIDE COMPLETE FRAMING DETAILS FOR NEW EXTERIOR
 WALL AT WALK-IN-CLOSET. SPECIFY ALL FRAMING FASTENERS.
 SEC. R301.1 OF FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 5- SHEET A2.0:
 A) REVISE PROPOSED WEST ELEVATION. GUEST BEDROOM WINDOW
 IS A CASEMENT WINDOW NOT SINGLE HUNG WINDOW. SEC.
 107.2.1 CITY AMENDMENTS.
  
 B) REVISE PROPOSED EAST ELEVATION. THERE IS A NEW
 FRENCH DOOR NOT "NEW IMPACT RESISTANT WINDOW". SEC.
 107.2.1 CITY AMENDMENTS.
  
 6- SHEET S2.): REVISE ENGINEERING CRITERIA. CURRENT
 CODE IS THE 2014 NOT 2010. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR ALL SIMPSON
 STRUCTURAL CONNECTORS SPECIFIED ON PLANS AND DETAILS.
 PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER PAGE
 AND PAGE SHOWING THE SPECIFIED CONNECTOR OR LIST THE
 CURRENT FLORIDA PRODUCT APPROVAL NEXT TO EACH SPECIFIED
 CONNECTOR. FAC 61G20-3.002(33).
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REPLACE AND REMOVE ANY REVISED SHEET. SUBMIT
 OLD COPIES FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-09-15 Cont ID  
Sent By albarran Date 2015-09-15 Time 10:56 Rev Time 0.00
Received By albarran Date 2015-09-15 Time 08:55 Sent To I
Notes
2015-09-15 11:01:18MADE A COUPLE OF CORRECTIONS TO THE PLANS WITH NOTES
 WRITTEN ON THE ELECTRICAL PAGE.
 1. CORRECTED THE REFERENCE OF "ROMEX" TO NM
 2.ADDED THE MISSING INTER-SYSTEM BONDING TERMINAL (NEC
 250.94) TO THE RISER DIAGRAM
 3. CORRECTED NOTE 28 TO READ 210.70
 CORRECTED NOTE 35 TO INCLUDE THE WEATHER RESISTANT
 DEVICE LISTING.OF NEC 406.9(B).

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2015-08-14 Cont ID  
Sent By fmittner Date 2015-08-14 Time 15:13 Rev Time 0.00
Received By fmittner Date 2015-08-14 Time 15:13 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2015-08-05 Cont ID  
Sent By fmittner Date 2015-08-05 Time 15:07 Rev Time 0.00
Received By fmittner Date 2015-08-05 Time 15:07 Sent To  
Notes
2015-08-05 15:08:27REQUIRES STAFF COA SUBMITTAL. FHM SPOKE TO ARCHITECT
 JEFFREY B. 8/5/15 TO EXPLAIN PROCESS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-10-02 Cont ID  
Sent By jgomez Date 2015-10-02 Time 11:53 Rev Time 0.00
Received By jgomez Date 2015-09-25 Time 09:33 Sent To  
Notes
2015-09-28 09:33:47RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-15 Cont ID  
Sent By albarran Date 2015-09-15 Time 11:08 Rev Time 0.00
Received By albarran Date 2015-07-14 Time 16:21 Sent To  
Notes
2015-09-15 11:06:519/15/15 PASSED THE FINAL REVIEW. CONTRACTOR NOTIFIED
 VIA EMAIL. SENT TO SMALL DENIED BIN "A". MA
2015-07-23 10:42:32R27

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2015-10-16 Cont ID  
Sent By jgomez Date 2015-10-16 Time 12:55 Rev Time 0.00
Received By jgomez Date 2015-10-16 Time 12:55 Sent To  
Notes
2015-10-16 12:56:59NO FEES. MU-2015-24559 BY DB. DATED 10/15/15.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-10-02 Cont ID  
Sent By jgomez Date 2015-10-02 Time 11:24 Rev Time 0.00
Received By jgomez Date 2015-10-02 Time 11:24 Sent To  
Notes
2015-10-02 11:24:251- BRING PLANS TO PALM BEACH (2300 N. JOG RD) FOR
 IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT
 FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-09-11 Cont ID  
Sent By jgomez Date 2015-09-11 Time 17:53 Rev Time 0.00
Received By jgomez Date 2015-09-11 Time 17:53 Sent To  
Notes
2015-09-11 17:53:191-- BRING PLANS TO PALM BEACH (2300 N. JOG RD) FOR
 IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT
 FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-10-14 Cont ID  
Sent By ccole Date 2015-10-14 Time 11:00 Rev Time 0.00
Received By ccole Date 2015-10-14 Time 11:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-10-02 Cont ID  
Sent By jgomez Date 2015-10-02 Time 11:53 Rev Time 0.00
Received By jgomez Date 2015-10-02 Time 11:53 Sent To  
Notes
2015-10-02 12:06:31RESIDENTIAL (R3) ADDITION/ALTERATION, SECOND MECHANICAL
 REVIEW CHECKLIST.
 CODE: FBC-5TH EDITION (2014).
  
 1- MASTER BEDROOM TRANSFER DUCT SIZE DOESN'T COMPLY
 WITH SEC. M1602.4 OF FBC-RESIDENTIAL, 5TH EDITION
 (2014).
  
 ***RESPONSE:
 TRANSFER DUCT WAS CHANGED TO 12". THIS STILL DOESN'T
 COMPLY. THERE IS A 14" SUPPLY DUCT FOR THE MASTER
 BEDROOM NOT 8". REVISE AS REQUIRED.
  
 2- PROVIDE THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE A/C FLOOR PLAN DESIGN AS REQUIRED
 BY SEC. 107.2.1 OF CITY AMENDMENTS TO FBC.
 NOTE: THERE ARE MANY REVISED A/C PLANS SUBMITTED ON
 DIFFERENT PAPER SIZES. PROVIDE ONLY ONE SIZE OF PLANS
 THAT CONTAINS COMPLETE FLOOR PLAN.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REPLACE AND REMOVE ANY REVISED SHEET. SUBMIT
 OLD COPIES FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-09-14 Cont ID  
Sent By jgomez Date 2015-09-14 Time 10:34 Rev Time 0.00
Received By jgomez Date 2015-09-14 Time 10:34 Sent To  
Notes
2015-09-14 10:46:50RESIDENTIAL (R3) ADDITION/ALTERATION, MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC-5TH EDITION (2014).
  
 1- MASTER BEDROOM TRANSFER DUCT SIZE DOESN'T COMPLY
 WITH SEC. M1602.4 OF FBC-RESIDENTIAL, 5TH EDITION
 (2014).
  
 2- DEN ROOM: PROVIDE COMPLIANCE WITH THE BALANCED
 RETURN AIR SEC. M1602.4 OF FBC-RESIDENTIAL, 5TH EDITION
 (2014).
  
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REPLACE AND REMOVE ANY REVISED SHEET. SUBMIT
 OLD COPIES FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-08-01 Cont ID  
Sent By tklarge Date 2015-08-01 Time 08:42 Rev Time 0.00
Received By tklarge Date 2015-08-01 Time 08:25 Sent To  
Notes
2015-08-01 08:44:28PROVISO: A CODE COMPLIANT SANITARY RISER SHALL BE
 SUBMITTED FOR REVIEW AND APPROVAL PRIOR TO ROUGH
 PLUMBING INSPECTION.

Review Stop Z ZONING
Rev No 1 Status P Date 2015-08-05 Cont ID  
Sent By fmittner Date 2015-08-05 Time 15:07 Rev Time 0.00
Received By fmittner Date 2015-08-05 Time 15:07 Sent To  
Notes
***NONE***