Plan Review Details - Permit 15070542
Plan Review Stops For Permit 15070542
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-09-29 Cont ID  
Sent By skennedy Date 2015-09-29 Time 08:56 Rev Time 0.00
Received By skennedy Date 2015-09-29 Time 08:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-09-21 Cont ID  
Sent By skennedy Date 2015-09-21 Time 11:14 Rev Time 0.00
Received By skennedy Date 2015-09-21 Time 11:14 Sent To  
Notes
2015-09-21 11:17:122ND REVIEW: FBC 2014 5TH ED.
  
 APPARENTLY CHANGES WERE MADE TO THE ORIGINAL PLAN AS A
 FUNCTION OF THE HISTORIC REVIEW AS TO RETAINING THE
 CARRIAGE DOORS. THE CHANGES, ALONG WITH THE ASSOCIATED
 PRODUCT APPROVALS FOR THE WINDOWS AND DOORS MUST BE
 REVIEWED BY THE DESIGNER OF RECORD. STEPHEN GAYDOSH.
 (NOTE, THE RE-SUBMITTED PLAN IS NOT CONSISTENT WITH THE
 PREVIOUS PLAN APPROVED BY THE HISTORIC PLANNER.
  
 INDICATE IF THE BUILDING IS EXEMPT FROM THE
 REQUIREMENTS OF THE FBC ENERGY CONSERVATION. IF NOT,
 PROVIDE EITHER:
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R303.9 REQUIRED HEATING.
 WHEN THE WINTER DESIGN TEMPERATURE IN TABLE R301.2(1)
 IS BELOW 60?F (16?C), EVERY DWELLING UNIT SHALL BE
 PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING
 A MINIMUM ROOM TEMPERATURE OF 68?F (20?C) AT A POINT 3
 FEET (914 MM) ABOVE THE FLOOR AND 2 FEET (610 MM) FROM
 EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE DESIGN
 TEMPERATURE. THE INSTALLATION OF ONE OR MORE PORTABLE
 SPACE HEATERS SHALL NOT BE USED TO ACHIEVE COMPLIANCE
 WITH THIS SECTION.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-03 Cont ID  
Sent By skennedy Date 2015-09-03 Time 16:34 Rev Time 0.00
Received By skennedy Date 2015-09-03 Time 16:34 Sent To  
Notes
2015-09-03 17:30:261ST REVIEW: FBC 2014 5TH ED.
  
 THE CODE REFERENCES LISTED ON THE PLAN ARE OUT OF DATE.
 PLEASE SPECIFY THE APPROPRIATE CODE IN EFFECT AND
 INDICATE THE LEVEL OF ALTERATION OR THAT THE WORK IS A
 CHANGE OF OCCUPANCY. REVIEW OF CITY RECORDS INDICATES
 THIS IS A CHANGE OF OCCUPANCY FROM STORAGE TO
 RESIDENTIAL PER DEFINITIONIN CHAPTER 2 OF THE
 FBC-EXISTING BUILDING VOLUME 5TH EDITION.
  
 APPARENTLY CHANGES WERE MADE TO THE ORIGINAL PLAN AS A
 FUNCTION OF THE HISTORIC REVIEW AS TO RETAINING THE
 CARRIAGE DOORS. THE CHANGES, ALONG WITH THE ASSOCIATED
 PRODUCT APPROVALS FOR THE WINDOWS AND DOORS MUST BE
 REVIEWED BY THE DESIGNER OF RECORD. STEPHEN GAYDOSH.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, WINDOW, AND DOOR SUBMITTALS.
  
 INDICATE IF THE BUILDING IS EXEMPT FROM THE
 REQUIREMENTS OF THE FBC ENERGY CONSERVATION. IS THE
 BUILDING TO BE CONDITIONED SPACE? IF NOT, PROVIDE
 EITHER:
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R303.9 REQUIRED HEATING.
 WHEN THE WINTER DESIGN TEMPERATURE IN TABLE R301.2(1)
 IS BELOW 60?F (16?C), EVERY DWELLING UNIT SHALL BE
 PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING
 A MINIMUM ROOM TEMPERATURE OF 68?F (20?C) AT A POINT 3
 FEET (914 MM) ABOVE THE FLOOR AND 2 FEET (610 MM) FROM
 EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE DESIGN
 TEMPERATURE. THE INSTALLATION OF ONE OR MORE PORTABLE
 SPACE HEATERS SHALL NOT BE USED TO ACHIEVE COMPLIANCE
 WITH THIS SECTION.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-09-29 Cont ID  
Sent By skennedy Date 2015-09-29 Time 08:56 Rev Time 0.00
Received By skennedy Date 2015-09-29 Time 08:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-09-21 Cont ID  
Sent By skennedy Date 2015-09-21 Time 11:17 Rev Time 0.00
Received By skennedy Date 2015-09-21 Time 11:17 Sent To  
Notes
2015-09-21 11:19:352ND REVIEW: FBC 2014 5TH ED. 2011 NEC
  
 CONDITIONALLY APPROVED. IT APPEARS THE OCP AND WIRE
 SIZE FOR THE MINI SPLIT ARE UNDERSIZED. PROVIDE
 SPECIFICATIONS PER THE MECHANICAL REVIEW REQUIREMENTS.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-09-03 Cont ID  
Sent By skennedy Date 2015-09-03 Time 18:14 Rev Time 0.00
Received By skennedy Date 2015-09-03 Time 18:13 Sent To  
Notes
2015-09-03 18:32:461ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 THE CODE REFERENCE IS OUT OF DATE. THE APPLICABLE BASE
 CODE IS LISTED ABOVE.
  
 MODIFY THE PLAN TO DEMONSTRATE COMPLIANCE WITH THE
 SECTIONS LISTED BELOW:
  
 FBC 107 MINIMUM INFORMATION REQUIRED. PROVIDE A PANEL
 SCHEDULE, AND LIST CIRCUITS, CONDUCTOR TYPE & SIZE, AND
 OCP,
  
 SHOW THE METHOD OF HEATING AND AND ANY ELECTRICAL
 CIRCUIT FOR THIS PURPOSE. (SEE COMMENT IN BUILDING
 REVIEW FOR REQUIRED HEATING) IF COOLING IS TO BE
 PROVIDED SHOW ELECTRICAL FOR COOLING.
  
 E4002.14 TAMPER-RESISTANT RECEPTACLES.
 IN AREAS SPECIFIED IN SECTION E3901.1, 125-VOLT, 15-
 AND 20-AMPERE RECEPTACLES SHALL BE LISTED
 TAMPER-RESISTANT RECEPTACLES.
  
 E3902.12 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION.
 ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE,
 15- AND 20-AMPERE OUTLETS INSTALLED IN FAMILY ROOMS,
 DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
 BEDROOMS, SUNROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED
 BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER
 INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT.
  
 E3703.4 BATHROOM BRANCH CIRCUITS.
 A MINIMUM OF ONE 20- AMPERE BRANCH CIRCUIT SHALL BE
 PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH
 CIRCUITS SHALL HAVE NO OTHER OUTLETS.
  
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2015-09-24 Cont ID  
Sent By fmittner Date 2015-09-24 Time 10:58 Rev Time 0.00
Received By fmittner Date 2015-09-24 Time 10:58 Sent To  
Notes
2015-09-24 11:04:39EXISTING CARRIAGE DOORS TO REMAIN. NEW GLASS DOORS TO
 BE INSTALLED BEHIND EXISTING DOORS. CONFIRMED BY OWNER
 SHAWN WOLF.

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2015-08-25 Cont ID  
Sent By fmittner Date 2015-08-25 Time 13:12 Rev Time 0.00
Received By fmittner Date 2015-08-25 Time 13:12 Sent To  
Notes
2015-08-25 13:13:01PLANS REVISED TO KEEP EXISTINGCARRIAGE DOORS AND
 INSTALL GLASS DOORS ON INSIDE.

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2015-07-22 Cont ID  
Sent By fmittner Date 2015-07-22 Time 14:48 Rev Time 0.00
Received By fmittner Date 2015-07-22 Time 14:48 Sent To  
Notes
2015-07-22 14:49:57IN HISTORIC DISTRICT, REQUIRES SUBMITTAL OF COA, VINYL
 WINDOWS NOT PERMITTED. QUESTIONS CONTACT FRIEDERIKE
 MITTNER, CITY HISOTRIC PRESERVATION PLANNER AT
 822-1457.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-09-29 Cont ID  
Sent By skennedy Date 2015-09-29 Time 08:57 Rev Time 0.00
Received By skennedy Date 2015-09-18 Time 15:53 Sent To  
Notes
2015-09-18 15:53:37RESUB ROUTED TO SKENNEDY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-04 Cont ID  
Sent By skennedy Date 2015-09-04 Time 08:05 Rev Time 0.00
Received By skennedy Date 2015-07-14 Time 15:45 Sent To  
Notes
2015-07-23 10:47:37R16

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2015-09-21 Cont ID  
Sent By skennedy Date 2015-09-21 Time 11:19 Rev Time 0.00
Received By skennedy Date 2015-09-21 Time 11:19 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-09-03 Cont ID  
Sent By skennedy Date 2015-09-03 Time 16:33 Rev Time 0.00
Received By skennedy Date 2015-09-03 Time 16:33 Sent To  
Notes
2015-09-03 16:34:491ST REVIEW: FBC 2014 5TH ED.
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND
 TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED
 WITH A COPY OF RECEIPT AS APPLICABLE.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-09-29 Cont ID  
Sent By skennedy Date 2015-09-29 Time 08:57 Rev Time 0.00
Received By skennedy Date 2015-09-29 Time 08:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-09-21 Cont ID  
Sent By skennedy Date 2015-09-21 Time 11:20 Rev Time 0.00
Received By skennedy Date 2015-09-21 Time 11:20 Sent To HIST
Notes
2015-09-21 11:21:532ND REVIEW: FBC 2014 5TH ED.
  
 SEE BUILDING REVIEW FOR ENERGY CODE REQUIREMENTS.
  
 FBC-ER403.6.1 PROVIDE AN EQUIPMENT SIZING CALCULATION.
  
 FBC- 107.3.5.3 PROVIDE INFORMATION ON THE EQUIPMENT
 SUCH AS AN EQUIPMENT SCHEDULE, ADDITIONALLY THE
 ELECTRICAL DEMAND MUST BE PROVIDED A.TO ASSURE THE
 ELECTRICAL PROVISIONS ARE ADEQUATE.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-09-04 Cont ID  
Sent By skennedy Date 2015-09-04 Time 08:44 Rev Time 0.00
Received By skennedy Date 2015-09-04 Time 08:44 Sent To  
Notes
2015-09-04 09:06:041ST REVIEW: FBC 2014 5TH ED.
  
 SEE BUILDING REVIEW FOR ENERGY CODE REQUIREMENTS.
  
 FBC-ER403.6.1 PROVIDE AN EQUIPMENT SIZING CALCULATION
 IN THE EVENT THE SPACE IS TO BE CONDITIONED.
  
 FBC- 107.3.5.3 ? PROVIDE A MECHANICAL PLAN TO SHOW
 SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER FBC-R
 M15. PROVIDE INFORMATION ON THE EQUIPMENT SUCH AS AN
 EQUIPMENT SCHEDULE.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-09-21 Cont ID  
Sent By skennedy Date 2015-09-21 Time 11:30 Rev Time 0.00
Received By skennedy Date 2015-09-21 Time 11:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-08-01 Cont ID  
Sent By tklarge Date 2015-08-01 Time 07:50 Rev Time 0.00
Received By tklarge Date 2015-08-01 Time 07:27 Sent To  
Notes
***NONE***