Plan Review Details - Permit 15070294
Plan Review Stops For Permit 15070294
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-09-03 Cont ID  
Sent By albarran Date 2015-09-03 Time 11:32 Rev Time 0.00
Received By albarran Date 2015-09-03 Time 10:14 Sent To I
Notes
2015-09-03 11:32:56ELECTRICAL PROVISO TO PERMIT 15070294
 THE SCOPE OF THIS PERMIT IS LIMITED TO THE ELECTRICAL
 CONNECTIONS TO THE HOOD. POWER SOURCE PROVIDED BY OHMS
 ELEC. ON PERMIT 15020088 TO THE MASTER PERMIT 14050421.
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-08-26 Cont ID  
Sent By albarran Date 2015-08-26 Time 14:32 Rev Time 0.00
Received By albarran Date 2015-08-26 Time 14:20 Sent To I
Notes
2015-08-26 14:34:03AS PREVIOUSLY STATED, PAGES I1 THROUGH I3, WHICH
 CONTAIN THE ELECTRICAL SPECS AND INSTALLATION
 INSTRUCTIONS ARE ILLEGIBLE AND CANT BE PROPERLY
 REVIEWED, NOR USED IN THE FIELD AS REFERENCE.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-08-03 Cont ID  
Sent By albarran Date 2015-08-03 Time 13:11 Rev Time 0.00
Received By albarran Date 2015-08-03 Time 11:00 Sent To I
Notes
2015-08-03 13:24:58PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS
 EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE
 MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO
 THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE
 CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW.
  
 1. ELECTRICAL DATA APPEARS TO BE ON SECTION I. THERE IS
 A SHEET I-1 AND I-3, BUT SHEET I-2 IS MISSING.
 2. THE ABOVE SHEETS ARE ILLEGIBLE FOR A PROPER REVIEW.
 3. IF YOU WILL BE RESUBMITTING WITH THE EXCESSIVELY
 LARGE SHEETS, I'D APPRECIATE YOU SEND ME A PDF VERSION
 SO I CAN REVIEW IT. BETTER YET, FEEL FREE TO PRE-SUBMIT
 A PDF VERSION. I WILL REVIEW AND MARK IT AS REQUIRED.
 WHEN YOU PRINT THE SHEETS MAKE SURE TO PRINT MY
 APPROVALS. THIS WAY I WILL HAVE REVIEWED THE SHEETS
 WHEN I COMES FOR THE ELECTRICAL REVIEW.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-07-29 Cont ID  
Sent By scaldero Date 2015-07-29 Time 16:52 Rev Time 0.00
Received By scaldero Date 2015-07-29 Time 16:26 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-09-03 Cont ID  
Sent By albarran Date 2015-09-03 Time 11:33 Rev Time 0.00
Received By albarran Date 2015-09-03 Time 09:30 Sent To  
Notes
2015-09-03 11:34:169/3/15 - PASSED ELECTRICAL REVIEW AS NOTED. CONTRACTOR
 NOTIFIED VIA EMAIL. SENT TO LARGE READY BIN "G". MA

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-08-26 Cont ID  
Sent By albarran Date 2015-08-26 Time 14:36 Rev Time 0.00
Received By albarran Date 2015-08-14 Time 14:45 Sent To  
Notes
2015-08-26 14:39:078/26/15 - FAILED ELECTRICAL REVIEW FOR THE SECOND TIME
 FOR THE SAME ISSUE. CONTRACTOR NOTIFIED VIA EMAIL. SENT
 TO LARGE DENIED BIN "G". MA
2015-08-14 14:45:16RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-08-03 Cont ID  
Sent By albarran Date 2015-08-03 Time 13:27 Rev Time 0.00
Received By albarran Date 2015-07-08 Time 15:42 Sent To  
Notes
2015-08-03 13:28:588/3/15 - FAILED ELECTRICAL REVIEW. CONTRACTOR NOTIFIED
 VIA EMAIL. SENT TO SMALL DENIED BIN "G". MA

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-08-17 Cont ID  
Sent By ccole Date 2015-08-17 Time 08:10 Rev Time 0.00
Received By ccole Date 2015-08-17 Time 08:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-07-31 Cont ID  
Sent By ccole Date 2015-07-31 Time 16:48 Rev Time 0.00
Received By ccole Date 2015-07-31 Time 16:48 Sent To  
Notes
2015-07-31 17:06:571ST REVIEW: FBC 2014 MECHANICAL
  
 1) SHEET M-3, HOOD SCHEDULE: LIST THE MAKE-UP AIR DATA
 FOR GH-1 AND GH-2. REFER TO SECTION 508.1 (MAKEUP AIR)
 AND 508.1.1 (MAKEUP AIR TEMPERATURE) FBC-14 MECHANICAL
 508.1 MAKEUP AIR.
 MAKEUP AIR SHALL BE SUPPLIED DURING THE OPERATION OF
 COMMERCIAL KITCHEN EXHAUST SYSTEMS THAT ARE PROVIDED
 FOR COMMERCIAL COOKING APPLIANCES. THE AMOUNT OF MAKEUP
 AIR SUPPLIED TO THE BUILDING FROM ALL SOURCES SHALL BE
 APPROXIMATELY EQUAL TO THE AMOUNT OF EXHAUST AIR FOR
 ALL EXHAUST SYSTEMS FOR THE BUILDING. THE MAKEUP AIR
 SHALL NOT REDUCE THE EFFECTIVENESS OF THE EXHAUST
 SYSTEM. MAKEUP AIR SHALL BE PROVIDED BY GRAVITY OR
 MECHANICAL MEANS OR BOTH- PLEASE PROVIDE CALCULATIONS
 AND LIST THE DATA TO VERIFY COMPLIANCE WITH THIS
 SECTION.
 508.1.1 MAKEUP AIR TEMPERATURE.
 THE TEMPERATURE DIFFERENTIAL BETWEEN MAKEUP AIR AND THE
 AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10
 DEGREES F (6 DEGREES C) EXCEPT WHERE THE ADDED HEATING
 AND COOLING LOADS OF THE MAKEUP AIR DO NOT EXCEED THE
 CAPACITY OF THE HVAC SYSTEM- CLARIFY HOW THE SYSTEM
 SHOWN ON THE PLAN IS MEETING COMPLIANCE.
 2) PROVIDE THE WIND LOAD DESIGN CRITERIA AND ENGINEERED
 DETAILS FOR INSTALLATION OF THE GREENHECK ROOF FANS AND
 FAN CURBS- PLEASE NOTE THAT THE DETAILS ON SHEET M-2
 REFERENCE STRUCTURAL DRAWINGS THAT HAVE NOT BEEN
 SUBMITTED WITH THE PLAN SETS.
 3) INDICATE COMPLIANCE WITH SECTION 507.9 EXCEPTION
 (STAINLESS STEEL HOOD BACKING SHALL EXTEND NOT LESS
 THAN 18 INCHES IN ALL DIRECTIONS FROM THE HOOD).
 4) THE SUBMITTED PLAN SHEETS WERE NOT BOUND TOGETHER-
 PLEASE RE-SUBMUIT PLANS THAT ARE BOUND TOGETHER-
 SECTION 107 WPB AMENDMENTS TO THE FBC-14 BUILDING CODE.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  
  