| 2015-07-08 15:24:34 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15070234 |
| | ADD: 424 52ND ST. |
| | CONT: SUNRISE CITY COM. HSG DEV. |
| | TEL: (772)201-2850 |
| | E-MAIL: [email protected] |
| | |
| | 5TH EDITION OF THE FLORIDA BUILDING CODE ADOPTED JUNE |
| | 30/ 2015 |
| | 5TH EDITION OF THE FBC/ EXISTING BUILDING CODE LEVEL |
| | REROOFING 708 |
| | |
| | 1ST REVIEW |
| | DATE: WED. JULY 08/ 2015 |
| | ACTION: BUILDING PROVISO |
| | |
| | 1) 1ST INSPECTION TO BE A 101 BUILDING PRE-INSPECTION |
| | TO DETERMINE CODE COMPLIANCE FOR A ROOF OVER PERMIT. |
| | WILL NEED TO VERIFY COMPLIANCE WITH: |
| | |
| | 5TH EDITION FBC-EXISTING BUILDING CODE SECTION: 708.3 |
| | RECOVERING (ROOF-OVER) VERSES REPLACEMENT. NEW ROOF |
| | COVERINGS SHALL NOT BE INSTALLED WITHOUT THE FIRST |
| | REMOVING ALL EXISITNG LAYERS OF ROOF COVERINGS WHERE |
| | ANY OF THE FOLLOWING CONDITIONS OCCUR: |
| | |
| | 1. WHERE THE EXISITNG ROOF OR ROOF COVERING IS WATER |
| | SOAKED OR HAS DETERIORATED TO THE POINT THAT THE |
| | EXISITNGROOF OR ROOF COVERING IS NOT ADEQUATE AS A BASE |
| | FOR |
| | ADDITIONAL ROOFING. |
| | 2. WHERE THE EXISITNG ROOF COVERING IS WOOD SHAKE, |
| | SLATE,CLAY CEMENT OR ASBESTOS-CEMENT TILE. |
| | 3. WHERE THE EXISTING ROOF HAS TWO OR MORE APPLICATIONS |
| | OF ANY TYPE OF ROOF COVERING. |
| | 4. WHEN BLISTERS EXIST IN ANY ROOFING, UNLESS BLISTERS |
| | ARE CUT OUT OR SCRAPED OPEN AND THE REMAINING MATERIALS |
| | SECURED DOWN BEFORE APPLYING ADDITIONAL ROOFING. |
| | 5. WHEN THE EXISITNG ROOF IS TO BE USED FOR ATTACHMENT |
| | FOR A NEW ROOF SYSTEM AND COMPLIANCE WITH THE |
| | SECUREMENT PROVISIONS OF 1504.1. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |