Plan Review Details - Permit 15070097
Plan Review Stops For Permit 15070097
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-12-11 Cont ID  
Sent By jwitmer Date 2015-12-11 Time 06:29 Rev Time 0.00
Received By jwitmer Date 2015-12-11 Time 05:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-10-19 Cont ID  
Sent By jwitmer Date 2015-10-19 Time 08:03 Rev Time 0.00
Received By jwitmer Date 2015-10-19 Time 06:43 Sent To  
Notes
2015-10-19 08:03:24BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15070097
 ADD: 402 & 404 50TH ST.
 CONT: BMB SOLUTIONS
 TEL: (561)503-1415
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W
 * 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, RESIDENTIAL.
  
 2ND REVIEW
 DATE: MON. OCT. 19/2015
 ACTION: DENIED
  
 1) 2ND REQUEST. THE VALUE ASSESSED TO THE PROJECT IS
 EXTREMELY LOW FOR THE VALUE OF THE PROJECT. THE VALUE
 OF THE WINDOW REPLACEMENT ALONE IS BETWEEN $20,000.00
 TO $25,000.00 FOR THE REPLACEMENT OF WINDOWS AND DOORS
 ALONE. SINCE THERE ARE SUB-PERMITS WITHIN THE PACKAGE
 THE VALUE FOR THE MEP PERMITS ARE ALSO TO BE ADDED TO
 THE VALUE OF THE MASTER PERMIT. NOTE THE IMPROVEMENT
 VALUE OF THIS PROPERTY IS $69,305.00.
 $69,305 X 0.30 = $ 20,791.50.
  
 PERMIT FEES/ PLAN REVIEW:
 W P B ADMINISTRATIVE CODE 108.2 SCHEDULE OF PERMIT
 FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS,
 MECHANICAL AND PLUMBING SYSTEMS OR ALTERATIONS
 REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID
 AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE
 ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 THIS PERMIT IS FOR THE REMOVAL AND INSTALATION OF 22
 WINDOWS, 8 MULLIONS AND 4 EXTERIOR DOORS. QUOTE
 SUBMITTED IS FOR 11 WINDOWS ONLY. IT DOES NOT APPEAR TO
 BE FOR THIS LOCATION, ONLY (1) WINDOW IS SIZED FOR A
 EGRESS WINDOW. NO MULLIONS NOR EXTERIOR DOORS.
  
 2) COMPLIED. THE PLANS INDICATE THEY WERE DESIGNED TO
 THE 2010 FBC, THE 5TH EDITION OF THE FBC WAS ADOPTED
 STATE WIDE JUNE 30, 2015. PLEASE UPDATE PLANS AND
 REQUIREMENTS INCLUDING THE WIND DESIGN.
  
 3) COMPLIED. UNDER THE 2014 FBC-EXISTING BUILDING 706.4
 WHEN REPLACING MORE THAN 25% OF THE GLAZED AREA OF
 GLAZING THE WINDOWS AND DOORS NEED TO MEET THE
 REQUIREMENTS OF LARGE MISSILE IMPACT GLAZING OR
 APPROVED STORM SHUTTERS.
  
 4) COMPLIED. 2010 FBC 107.3.4.1 PRODUCT APPROVALS.
 THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE
 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 5) COMPLIED. COMPONENTS & CLADDING 2010 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING, FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE
 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS. NOT REVIEWED BY THE DESIGNER OF
 RECORD.
 (B) WINDOWS & MULLIONS, MCY ENGINEERING. WAS NOT
 SUBMITTED WITH A FLORIDA OR MIAMI-DADE COVER SHEET. NOT
 REVIEWED BY THE DESIGNER OF
 RECORD.
 (E) STORM SHUTTERS (IF THE GLAZED OPENINGS DO NOT HAVE
 LARGE MISSILE IMPACT TESTING)
  
 6) COMPLIED. SHEET1.1 & 2.1 BOTH SHOW A CORNER POST
 WITH WINDOWS ON BOTH SIDES, PLEASE PROVIDE WHAT TYPE OF
 FRAMING SYSTEM THIS CORNER POST IS CONSISTED OF AND HOW
 DOES IT CONNECT TO THE MWFRS MAIN WIND FORCE RESISTING
 SYSTEM.
  
 7) 2ND REQUEST. 2014 EXISTING BUILDING CODE, 707.1.
 MINIMUM REQUIREMENTS. ALTERATION SUBJECT TO THIS
 CHAPTER SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, ENERGY CONSERVATION.
  
 2014 ENERGY CODE DEFINITIONS: RENOVATED BUILDINGS.
 ARESIDENTIAL BUILDING UNDERGOING ALATERATIONS THAT
 VARIES OR CHANGES INSULATION, HVAC SYSTEMS WATER
 HEATING SYSTEMS, OR EXTERIOR ENVELOPE CONDITIONS,
 PROVIDED THE ESTIMATE COST OF RENOVATION EXCEEDS 30
 PERCENT OF THE ASSESSED VALUE OF THE STRUCTURE. SEE
 COMMENT # 1, 30% OF THE APPRAISED IMPROVEMENT VALUE OF
 THE STRUCTURE IS $20,791.50.
  
 PLEASE REVIEW 2014 FBC-ENERGY CODE R101.4.3 ALTERATIONS
 AND TABLE R402.1.1 INSULATION & FENESTRATIONS
 REQUIREMENTS BY COMPONENT. NOTE FOR ZONE # 1 THE
 FENESTRATION U-FACTOR OF 0.65 AND GLAZED FENESTRATION
 SHGC OF 0.25. THE DESIGNER MAY LOOK AT THIS AS
 PRESCRIPTIVE OR PREFORMANCE BASED.
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-07-28 Cont ID  
Sent By jwitmer Date 2015-07-28 Time 08:14 Rev Time 0.00
Received By jwitmer Date 2015-07-28 Time 07:15 Sent To  
Notes
2015-07-28 08:14:35BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15070097
 ADD: 402 & 404 50TH ST.
 CONT: BMB SOLUTIONS
 TEL: (561)503-1415
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W
 * 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, RESIDENTIAL.
  
 1ST REVIEW
 DATE: TUES. JULY 28/2015
 ACTION: DENIED
  
 1) THE VALUE ASSESSED TO THE PROJECT IS EXTREMELY LOW
 FOR THE VALUE OF THE PROJECT. THE VALUE OF THE WINDOW
 REPLACEMENT ALONE IS BETWEEN $20,000.00 TO $25,000.00
 FOR THE REPLACEMENT OF WINDOWS AND DOORS ALONE. SINCE
 THERE ARE SUB-PERMITS WITHIN THE PACKAGE THE VALUE FOR
 THE MEP PERMITS ARE ALSO TO BE ADDED TO THE VALUE OF
 THE MASTER PERMIT. NOTE THE IMPROVEMENT VALUE OF THIS
 PROPERTY IS $69,305.00.
 $69,305 X 0.30 = $ 20,791.50.
  
 PERMIT FEES/ PLAN REVIEW:
 W P B ADMINISTRATIVE CODE 108.2 SCHEDULE OF PERMIT
 FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS,
 MECHANICAL AND PLUMBING SYSTEMS OR ALTERATIONS
 REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID
 AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE
 ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 2) THE PLANS INDICATE THEY WERE DESIGNED TO THE 2010
 FBC, THE 5TH EDITION OF THE FBC WAS ADOPTED STATE WIDE
 JUNE 30, 2015. PLEASE UPDATE PLANS AND REQUIREMENTS
 INCLUDING THE WIND DESIGN.
  
 3) UNDER THE 2014 FBC-EXISTING BUILDING 706.4 WHEN
 REPLACING MORE THAN 25% OF THE GLAZED AREA OF GLAZING
 THE WINDOWS AND DOORS NEED TO MEET THE REQUIREMENTS OF
 LARGE MISSILE IMPACT GLAZING OR APPROVED STORM
 SHUTTERS.
  
 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 5) COMPONENTS & CLADDING 2010 FBC-B 1609.1.2 PROTECTION
 OF OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING,
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS. NOT REVIEWED BY THE DESIGNER OF
 RECORD.
 (B) WINDOWS & MULLIONS, MCY ENGINEERING. WAS NOT
 SUBMITTED WITH A FLORIDA OR MIAMI-DADE COVER SHEET. NOT
 REVIEWED BY THE DESIGNER OF
 RECORD.
 (E) STORM SHUTTERS (IF THE GLAZED OPENINGS DO NOT HAVE
 LARGE MISSILE IMPACT TESTING)
  
 6) SHEET1.1 & 2.1 BOTH SHOW A CORNER POST WITH WINDOWS
 ON BOTH SIDES, PLEASE PROVIDE WHAT TYPE OF FRAMING
 SYSTEM THIS CORNER POST IS CONSISTED OF AND HOW DOES IT
 CONNECT TO THE MWFRS MAIN WIND FORCE RESISTING SYSTEM.
  
 7) 2014 EXISTING BUILDING CODE, 707.1. MINIMUM
 REQUIREMENTS. ALTERATION SUBJECT TO THIS CHAPTER SHALL
 COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING
 CODE, ENERGY CONSERVATION.
  
 2014 ENERGY CODE DEFINITIONS: RENOVATED BUILDINGS.
 ARESIDENTIAL BUILDING UNDERGOING ALATERATIONS THAT
 VARIES OR CHANGES INSULATION, HVAC SYSTEMS WATER
 HEATING SYSTEMS, OR EXTERIOR ENVELOPE CONDITIONS,
 PROVIDED THE ESTIMATE COST OF RENOVATION EXCEEDS 30
 PERCENT OF THE ASSESSED VALUE OF THE STRUCTURE. SEE
 COMMENT # 1, 30% OF THE APPRAISED IMPROVEMENT VALUE OF
 THE STRUCTURE IS $20,791.50.
  
 PLEASE REVIEW 2014 FBC-ENERGY CODE R101.4.3 ALTERATIONS
 AND TABLE R402.1.1 INSULATION & FENESTRATIONS
 REQUIREMENTS BY COMPONENT. NOTE FOR ZONE # 1 THE
 FENESTRATION U-FACTOR OF O.65 AND GLAZED FENESTRATION
 SHGC OF 0.25. THE DESIGNER MAY LOOK AT THIS AS
 PRESCRIPTIVE OR PREFORMANCE BASED.
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-11-05 Cont ID  
Sent By ppetty Date 2015-11-05 Time 09:31 Rev Time 0.00
Received By ppetty Date 2015-11-05 Time 09:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-08-03 Cont ID  
Sent By skennedy Date 2015-08-03 Time 13:04 Rev Time 0.00
Received By skennedy Date 2015-08-03 Time 13:04 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2015-07-14 Time   Rev Time  
Received By   Date 2015-07-10 Time   Sent To  
Notes
2015-07-14 15:28:31DUPLEX ( FIRE INSPECTION NOT REQUIRED )

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2015-10-07 Cont ID  
Sent By fmittner Date 2015-10-07 Time 08:42 Rev Time 0.00
Received By fmittner Date 2015-10-07 Time 08:42 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2015-07-24 Cont ID  
Sent By fmittner Date 2015-07-24 Time 10:12 Rev Time 0.00
Received By fmittner Date 2015-07-24 Time 10:12 Sent To  
Notes
2015-07-24 10:13:43PROPERTY LOCATED IN HISTORIC DISTRICT. NEED MORE
 INFORMATION ON WINDOWS, FRAME COLOR (SHALL BE WHITE),
 GLASS (LOW-E OR CLEAR) AND GRID PATTERN. QUESTIONS
 CONTACT FRIEDERIKE MITTNER AT 822-1457.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-12-11 Cont ID  
Sent By   Date 2015-12-11 Time 06:30 Rev Time 0.00
Received By cpuell Date 2015-11-30 Time 15:45 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-11-05 Cont ID  
Sent By cpuell Date 2015-11-05 Time 09:48 Rev Time 0.00
Received By cpuell Date 2015-10-01 Time 10:52 Sent To  
Notes
2015-10-02 10:53:08B30

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-08-03 Cont ID  
Sent By skennedy Date 2015-08-03 Time 13:04 Rev Time 0.00
Received By skennedy Date 2015-07-02 Time 08:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-12-01 Cont ID  
Sent By ccole Date 2015-12-01 Time 07:09 Rev Time 0.00
Received By ccole Date 2015-12-01 Time 06:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-10-08 Cont ID  
Sent By ccole Date 2015-10-08 Time 11:28 Rev Time 0.00
Received By ccole Date 2015-10-08 Time 11:24 Sent To  
Notes
2015-10-08 11:50:412ND REVIEW: FBC 2014 MECHANICAL
 PERMIT #15070097
 10/8/15
  
 1) IN RESPONSE TO THE PREVIOUS COMMENTS REGARDING AC IN
 UNITS 402 & 404, TWO SETS OF ENERGY AND AN AC LOAD
 SUMMARY HAVE BEEN SUBMITTED FOR UNIT 402, BUT NONE HAVE
 BEEN SUBMITTED FOR 404. THE CALCULATIONS SUBMITTED FOR
 402 INDICATE A 16 SEER SYSTEM, HOWEVER THE PLAN IS
 INDICATING A 13 SEER SYSTEM. ADDITIONALLY THE MODEL
 MUMBERS ON THE PLAN DON'T MATCH THE MODEL NUMBERS ON
 THE LOAD SUMMARY: PLEASE CORRECT. PLEASE NOTE THAT THE
 AC SUMMARY CALCS MUST HAVE THE MANUAL J WORKSHEETS
 ATTACHED FOR COMPLETE REVIEW.
 2) THIS IS THE SECOND REQUEST FOR A MECHANICAL
 SUB-PERMIT AND ADJUSTED PERMIT VALUE INCREASE FOR THE
 COST OF THE AC SYSTEM- LABOR, MATERIALS, AND EQUIPMENT.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-07-17 Cont ID  
Sent By ccole Date 2015-07-17 Time 11:39 Rev Time 0.00
Received By ccole Date 2015-07-17 Time 11:39 Sent To  
Notes
2015-07-17 11:45:541ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #15070097
  
 1) SHEET 3.1.: PROVIDE A SCOPE OF WORK OUTLINE FOR AC
 ON THE PLAN. CLARIFY IF THE SYSTEMS SHOWN ARE: A) EXACT
 SAME SIZE, SAME LOCATION REPLACEMENTS OF EQUIPMENT AND
 COMPONENTS. B) LARGER CAPACITY EQUIPMENT UPGRADES. C)
 EQUIPMENT REPLACEMENTS WITH RELOCATIONS. PLEASE NOTE
 THAT EQUIPMENT SIZING CALCULATIONS FOR COOLING AND
 HEATING EQUIPMENT SIZING ARE REQUIRED FOR EITHER ITEMS
 SYSTEM SIZING INCREASE, OR EQUIPMENT RELOCATIONS.
 2. SHEET 3.1: PROVIDE AC EQUIPMENT SCHEDULES ON THE
 PLANS INDICATING MAKES AND MODELS OF AIR HANDLERS AND
 CONDENSERS, COOLING AND HEATING CAPACITIES, EFFIENCY
 RATINGS, ELECTRIAL DATA ETC.
 3. SHEET 3.1: INDICATE THE DIMENSIONS OF THE R/A AND
 T/A GRILLS SHOWN ON THE PLAN. NOTE: THE T/A GRILLS ARE
 ACTUALLY BEING USED AS R/A GRILLS: PLEASE CORRECT.
 4. SUBMIT A MECHANICAL SUB-PERMIT APPLICATION, AND ADD
 THE COST OF THE AC WORK TO THE TOTAL PROJECT VALUE ON
 THE PERMIT APPLICATION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-10-13 Cont ID  
Sent By gjohnson Date 2015-10-13 Time 12:09 Rev Time 0.00
Received By gjohnson Date 2015-10-13 Time 12:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-07-30 Cont ID  
Sent By tklarge Date 2015-07-30 Time 06:23 Rev Time 0.00
Received By tklarge Date 2015-07-30 Time 06:05 Sent To E
Notes
***NONE***