Plan Review Details - Permit 15070042
| Plan Review Stops For Permit 15070042 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-08-26 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-26 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-08-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-08-18 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-18 |
Time |
12:28 |
Sent To |
|
|
| Notes |
| 2015-08-18 12:32:08 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. THERE ARE MULTIPLE REFERENCES TO FBC 2010; REVISE TO | | | GOVERNING CODE (FBC 2014). | | | | | | 2ND REVIEW, SEE STRUCTURAL NOTES AND ANY OTHER PLACES | | | AS APPLICABLE; REVISE TO GOVERNING CODE. | | | | | | 2. REVISE PLAN TO INCLUDE WIND DESIGN CRITERIA FBC 2014 | | | RESIDENTIAL 301. | | | | | | NOT ADDRESSED. INCLUDE WIND SPEED AND EXPOSURE | | | CLASSIFICATION. | | | | | | 3. STANDARDS REFERENCED STATE "CURRENT EDITION"; SEE | | | FBC 2014 RESIDENTIAL CHAPTER 46. STANDARDS TO COMPLY | | | WITH THE GOVERNING CODE. IF ENGINEER WOULD LIKE TO | | | PROPOSE A DIFFERENT EDITION, THIS IS TO BE SUBMITTED | | | USING ALTERNATIVE MATERIALS AND METHODS FBC 104.11. | | | | | | NOT ADDRESSED. | | | | | | 4. PLAN STATES THAT BUILDING TYPE IS IIB, CONFIRM AND | | | CLARIFY OR REVISE. TYPE IIB IS NON COMBUSTIBLE. MOST | | | SFD STRUCTURES HAVE WOOD TRUSSES OR FRAMING, FBC 107. | | | | | | NOT ADDRESSED. | | | | | | NEW COMMENT: | | | | | | 5. PLAN SHOWS EXISTING IMPACT WINDOWS. PROVIDE PERMIT | | | NUMBER FOR THIS WORK. IT IS NOT CONSIDERED "EXISTING" | | | IF NOT PERMITTED. | | | | | | 6. WHEN RESUBMITTING, CONTRACTOR COMPANY NAME SHOULD BE | | | IN THE LINE FOR "CONTRACTOR." AS THIS IS HOW PLANS ARE | | | FILED IN THIS DEPARTMENT, ANY OTHER INFORMATION | | | (QUALIFIER OR CONTACT PERSON) IN THIS LINE COULD CAUSE | | | THE PLAN TO BE MISPLACED / MISFILED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-07-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-07-07 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-07-07 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2015-07-07 15:35:31 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. THERE ARE MULTIPLE REFERENCES TO FBC 2010; REVISE TO | | | GOVERNING CODE (FBC 2014). | | | | | | 2. REVISE PLAN TO INCLUDE WIND DESIGN CRITERIA FBC 2014 | | | RESIDENTIAL 301. | | | | | | 3. STANDARDS REFERENCED STATE "CURRENT EDITION"; SEE | | | FBC 2014 RESIDENTIAL CHAPTER 46. STANDARDS TO COMPLY | | | WITH THE GOVERNING CODE. IF ENGINEER WOULD LIKE TO | | | PROPOSE A DIFFERENT EDITION, THIS IS TO BE SUBMITTED | | | USING ALTERNATIVE MATERIALS AND METHODS FBC 104.11. | | | | | | 4. PLAN STATES THAT BUILDING TYPE IS IIB, CONFIRM AND | | | CLARIFY OR REVISE. TYPE IIB IS NON COMBUSTIBLE. MOST | | | SFD STRUCTURES HAVE WOOD TRUSSES OR FRAMING, FBC 107. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-08-26 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-24 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2015-08-24 13:19:40 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-08-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-08-18 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-17 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2015-08-17 13:13:03 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-07-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-07-07 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-07-01 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2015-07-01 15:36:50 | ROUTED TO BLDG >5,000 |
|
|
|