Plan Review Details - Permit 15061466
Plan Review Stops For Permit 15061466
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2015-12-15 Cont ID  
Sent By jgomez Date 2015-12-15 Time 08:24 Rev Time 0.00
Received By jgomez Date 2015-12-15 Time 08:24 Sent To  
Notes
2015-12-15 08:27:56BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR:
 A) CUSTOM ENTRY DOOR AS SHOWN ON PLANS. PROVIDE
 COMPLETE ENGINEERING PACKAGE FOR BUILDING OFFICIAL
 APPROVAL. CONTACT BROWN AT [email protected].
 B) STEEL PANEL WALL SYSTEM AS SHOWN ON PLANS.
 C) METAL ROOF AS SHOWN ON PLANS.
 D) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON
 PLANS.
 E) PROVIDE COMPLETE DETAILS, SPECIFICATIONS AND PRODUCT
 APPROVAL FOR THE FINISH COVERING UNDERLAYMENT OF THE
 SECOND FLOOR COVERED TERRACE.
 3- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS.
 4- PRIOR TO FABRICATION AND INSTALLATION PROVIDE
 COMPLETE ENGINEER PACKAGE FOR THE BAR JOIST AND
 CONCRETE DECK SYSTEMS, STAIRWAY , HANDRAILS AND
 GUARDRAILS APPROVED BY THE DESIGNER OF RECORD.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-12-04 Cont ID  
Sent By jgomez Date 2015-12-03 Time 17:36 Rev Time 0.00
Received By jgomez Date 2015-12-03 Time 17:36 Sent To  
Notes
2015-12-03 17:48:19 
 NOTE:
 COMMENTS BELOW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS TO ISSUE PERMIT AND REVISED PLANS ADDRESSING THE
 COMMENTS WILL BE SUBMITTED LATER. FEES MAY APPLY. NEED
 CONTRACTOR'S APPROVAL TO GO AHEAD WITH THE PROVISO
 OPTION. BUT, BEFORE ISSUING THE PERMIT, ALL THE
 STRUCTURAL DRAWINGS NEED TO BE RE-SUBMITTED WITHOUT THE
 "NOT FOR CONSTRUCTION" NOTE.
  
 1- REVISED SOIL TEST REPORT NEEDS THE ENGINEER'S
 ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471
 F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) CUSTOM ENTRY DOOR AS SHOWN ON PLANS. PROVIDE
 COMPLETE ENGINEERING PACKAGE FOR BUILDING OFFICIAL
 APPROVAL. CONTACT BROWN AT [email protected].
 RESPONSE: IT WILL BE SUBMITTED AT A FUTURE DATE PRIOR
 TO INSTALLATION. OK.
  
 B) STEEL PANEL WALL SYSTEM AS SHOWN ON PLANS.
 RESPONSE: WILL BE SUBMITTED LATER. OK.
  
 C) METAL ROOF AS SHOWN ON PLANS.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 D) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON
 PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN
 PRESSURES.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 E) PROVIDE COMPLETE DETAILS, SPECIFICATIONS AND PRODUCT
 APPROVAL FOR THE FINISH COVERING UNDERLAYMENT OF THE
 SECOND FLOOR COVERED TERRACE. SEC. 107.2.1 CITY
 AMENDMENTS.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 3- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
 NOTE: PLEASE PLACE THE REVIEW STAMP ON THE FRONT OF THE
 PRODUCT APPROVAL COVER PAGE NOT ON THE BACK (OR ON ANY
 OTHER FRONT PAGE WHERE THERE IS ENOUGH ROOM FOR THE
 STAMP). SCANNING DOCUMENTS FOR RECORD KEEPING IS NOT
 ADEQUATE WHEN STAMPS ARE ON THE BACK OF THE PAGE.
  
 4- PRIOR TO FABRICATION AND INSTALLATION PROVIDE
 COMPLETE ENGINEER PACKAGE FOR THE BAR JOIST AND
 CONCRETE DECK SYSTEMS, STAIRWAY , HANDRAILS AND
 GUARDRAILS APPROVED BY THE DESIGNER OF RECORD.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING.
 SUBMIT OLD COPIES FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-11-04 Cont ID  
Sent By jgomez Date 2015-11-03 Time 15:27 Rev Time 0.00
Received By jgomez Date 2015-11-03 Time 15:27 Sent To  
Notes
2015-11-03 15:27:58NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC-RESIDENTIAL -5TH EDITION(2014.
  
 1- THE 2014 BC TOOK EFFECT ON JUNE 30TH, 2015. PERMIT
 APPLICATION WAS SUBMITTED ON JUNE 30TH. BUILDING REVIEW
 WILL BE DONE BASED ON THE NEW CODE. PLEASE UPDATE ALL
 PLANS AND NOTES AS REQUIRED.
 RESPONSE: SHEET A0 WAS NOT REVISED. STILL REFERENCING
 THE 2010 CODE.
  
 2- ARCHITECTURAL PLANS TITLE BLOCK IS MISSING ALL THE
 INFORMATION OF THE ARCHITECT WHO IS SIGNING AND SEALING
 THE PLANS AS REQUIRED BY FAC 61G1-16.004.
 RESPONSE: TITLE BLOCK WAS NOT REVISED. THE ARCHITECT'S
 REQUIRED INFORMATION STILL NO PROVIDED.
  
 3- A) SOIL TEST REPORT SUBMITTED: PROJECT DESCRIPTION
 DOESN'T MATCH PROPOSED CONSTRUCTION. BUILDING AREA IS
 SIGNIFICANTLY HIGHER AND THE TYPE OF PROPOSED
 CONSTRUCTION NEEDS ATTENTION TOO. REVISE REPORT AS
 REQUIRED. SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION
 (2014).
  
 B) ENGINEER OF RECORD TO REVIEW REVISED SOIL TEST
 REPORT BASED ON THE ACTUAL PROPOSED CONSTRUCTION AND
 SQUARE FOOTAGE. AND, ACKNOWLEDGE IN WRITING TO THIS
 OFFICE THAT GEOTECHNICAL FOUNDATION RECOMMENDATIONS
 WERE ADOPTED IN THE DESIGN, INCLUDING THE
 RECOMMENDATION TO STRUCTURALLY SEPARATE FOOTING AND
 COLUMNS FROM THE FLOOR SLAB. OTHERWISE, PROVIDE
 ENGINEERING ANALYSIS FOR PROPOSED FOOTING DESIGN SHOWN
 ON PLANS. SEC. 107.2.1.3 CITY AMENDMENTS.
  
 4- NEW ELEVATOR/FLOOD ZONE NOTE ON SHEET A6: CODE SEC.
 R1403.5. & 6 SPECIFIED ON NOTE #1 DOESN'T EXIST ON THE
 2014 CODE AND DOESN'T APPLY TO ELEVATOR EQUIPMENT.
 REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 5- REVISE FOUNDATION PLAN ON SHEET S1 TO MATCH REVISED
 ARCHITECTURAL PLAN SHOWING LANDING FROM THE CLUB ROOM
 TO THE COVERED LANAI AS REQUIRED BY SEC. R311.3 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 6- PROVIDE DETAILS AND SPECIFICATIONS FOR THE DESIGN OF
 THE STRUCTURAL SUPPORTS OF THE ELEVATOR AS REQUIRED BY
 ELEVATOR SPECS SUBMITTED AND SEC. R301 FBC-RESIDENTIAL,
 5TH EDITION (2014).
  
 7- PROVIDE COMPLIANCE WITH THE ACCESSIBILITY SEC. R320.
 RESPONSE: 2'-6" DOORS DON'T PROVIDE 29" CLEAR OPENING.
  
 8- SHEET A6: SPECIFY OVERFLOW DRAINS OR SCUPPERS AS
 REQUIRED BY SEC. R903.4.1.
 RESPONSE: OVERFLOW DRAINS WERE NOT SPECIFIED. THESE ARE
 ADDITIONAL TO THE REGULAR FLOOR DRAINS. SEE SEC. R903.1
  
 9- SHEET A7: SPECIFY OVERFLOW DRAINS OR SCUPPERS AS
 REQUIRED BY SEC. R903.4.1.
 RESPONSE: OVERFLOW DRAINS WERE NOT SPECIFIED. THESE ARE
 ADDITIONAL TO THE REGULAR FLOOR DRAINS. SEE SEC. R903.1
  
 10- PROVIDE ICC EVALUATION REPORT FOR THE SPRAY
 INSULATION SPECIFIED ON PLANS. SEC. R316.
 RESPONSE: EVALUATION REPORT ESR-1826 SUBMITTED EXPIRED
 ON FEBRUARY 1, 2015. NEED CURRENT ONE. REMAINDER: AND,
 ARCHITECT TO APPROVE PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 11- REVISE ENERGY CALCULATIONS SUBMITTED:
 A) ROOF INFORMATION ON PAGE 3 OF 7: REVISE ROOF TYPE
 AND MATERIALS TO MATCH PLANS. PLANS SHOW MODIFIED
 BITUMEN AND METAL ROOF. SEC. R101.5.1.1.2 OF FBC-
 ENERGY CONSERVATION, 5TH EDITION (2014).
 RESPONSE: INFORMATION IS INCORRECT. THE FLAT ROOF IS
 NOT METAL. THE FLAT ROOF IS MODIFIED BITUMEN AND THERE
 IS A PITCHED ROOF WITH METAL ROOF. SEE PLANS AND REVISE
 AS REQUIRED.
  
 B) CEILING INFORMATION ON PAGE 3 OF 7: R VALUE TO MATCH
 PLANS AND PAGE 1 OF 7. SEC. R101.5.1.1.2 OF FBC- ENERGY
 CONSERVATION, 5TH EDITION (2014).
 RESPONSE: INFORMATION SUBMITTED STILL DOESN'T MATCH.
  
 C) OWNER/AGENT TO CERTIFY AND DATE BOTTOM OF FORM AS
 REQUIRED BY SEC. R103.1.1.2 OF FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 D) REVISE THE CLIMATE ZONE ON PAGE 2 OF 6. PALM BEACH
 IS NOT ZONE 2.. SEE TABLE R301.1 OF FBC- ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 NOTE:
 LABEL FOR THE WINDOWS AND DOORS SHOWING THE U-FACTOR
 AND SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS
 WILL BE REQUIRED WHEN ENERGY CALCULATIONS ARE NOT USING
 THE DEFAULT FACTOR FOR GLAZING.
  
 12- REVISED HANDRAIL DETAIL TO SHOW COMPLIANCE WITH THE
 OPENING LIMITATIONS OF THE TRIANGULAR AREA FORMED BY
 THE TREAD, RISER AND BOTTOM OF RAIL AS REQUIRED SEC.
 R312.1.3 OF FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 13- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) CUSTOM ENTRY DOOR AS SHOWN ON PLANS. PROVIDE
 COMPLETE ENGINEERING PACKAGE FOR BUILDING OFFICIAL
 APPROVAL. CONTACT BROWN AT [email protected].
 RESPONSE: IT WILL BE SUBMITTED AT A FUTURE DATE PRIOR
 TO INSTALLATION. OK.
  
 B) STEEL PANEL WALL SYSTEM AS SHOWN ON PLANS.
 RESPONSE: WILL BE SUBMITTED LATER. OK.
  
 C) 14" EXHAUST AIR GRILLS AS SHOWN ON PLANS.
 RESPONSE: PROVIDE THE ACTUAL MIAMI-DADE NOA OR FLORIDA
 PRODUCT APPROVAL. AND DESIGNER OF RECORD TO APPROVE
 BEFORE SUBMITTAL TO THIS OFFICE.
  
 D) METAL ROOF AS SHOWN ON PLANS.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 E) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON
 PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN
 PRESSURES.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 14- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
 NOTE: PLEASE PLACE THE REVIEW STAMP ON THE FRONT OF THE
 PRODUCT APPROVAL COVER PAGE NOT ON THE BACK (OR ON ANY
 OTHER FRONT PAGE WHERE THERE IS ENOUGH ROOM FOR THE
 STAMP). SCANNING DOCUMENTS FOR RECORD KEEPING IS NOT
 ADEQUATE WHEN STAMPS ARE ON THE BACK OF THE PAGE.
  
 15- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 FINISH COVERING OF THE SECOND FLOOR COVERED TERRACE.
 SEC. 107.2.1 CITY AMENDMENTS.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 16- PRIOR TO FABRICATION AND INSTALLATION PROVIDE
 COMPLETE ENGINEER PACKAGE FOR THE BAR JOIST AND
 CONCRETE DECK SYSTEMS, STAIRWAY , HANDRAILS AND
 GUARDRAILS APPROVED BY THE DESIGNER OF RECORD.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING.
 SUBMIT OLD COPIES FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-08-28 Cont ID  
Sent By gjohnson Date 2015-08-28 Time 08:33 Rev Time 0.00
Received By jgomez Date 2015-08-28 Time 08:25 Sent To  
Notes
2015-08-28 08:36:08NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS.
 CODE: FBC-RESIDENTIAL -5TH EDITION(2014.
  
 1-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  
 2- THE 2014 FBC TOOK EFFECT ON JUNE 30TH, 2015. PERMIT
 APPLICATION WAS SUBMITTED ON JUNE 30TH. BUILDING REVIEW
 WILL BE DONE BASED ON THE NEW CODE. PLEASE UPDATE ALL
 PLANS AND NOTES AS REQUIRED.
  
 3- FOR YOUR INFORMATION THIS PROPERTY IS LOCATED IN
 FLOOD ZONE A5. ELEVATIONS CERTIFICATES WILL BE REQUIRED
 DURING CONSTRUCTION.
  
 4- ARCHITECTURAL PLANS TITLE BLOCK IS MISSING ALL THE
 INFORMATION OF THE ARCHITECT WHO IS SIGNING AND SEALING
 THE PLANS AS REQUIRED BY FAC 61G1-16.004.
  
 5- PROVIDE SOIL TEST REPORT (2 COPIES). SEC. R401.4 OF
 2010 FBC-RESIDENTIAL-5TH EDITION (2014).
  
 6-SHEET A-1: REVISE THE RETENTION NOTE ON SOIL/DRAINAGE
 NOTES. SEE SEC. R318.5 AND SEC. R401.3.
  
 7- SHEET A5:
 A) A LANDING IS REQUIRED FROM THE EXERCISE ROOM TO THE
 COVERED LANAI AS REQUIRED BY SEC. R311.3
  
 B) PROVIDE SPECIFICATIONS FOR GARAGE DOORS LEADING TO
 THE CLUB ROOM AND TO THE FOYER SHOWING COMPLIANCE WITH
 SEC. R302.5.1. ALSO, ALL THE DOORS NEED TO BE EQUIPPED
 WITH A SELF-CLOSING DEVICE. PROVIDE SPECIFICATIONS ON
 PLANS.
  
 C) PROPERTY IS LOCATED IN FLOOD ZONE A5. PROVIDE SPECS
 FOR THE ELEVATOR PIT AND PIT FOR HYDRAULIC LIFT SHOWING
 COMPLIANCE WITH SEC. R322.
  
 D) DOOR 09 DOESN'T MATCH DOOR SCHEDULE. REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 E) AREA CALCULATIONS ARE INCORRECT. THE ADDITION OF THE
 AREAS IS INCORRECT. REVISE AS REQUIRED. SEC. 107.2..1
 CITY AMENDMENTS.
  
 8- PROVIDE COMPLIANCE WITH THE ACCESSIBILITY SEC. R320.
  
 9- SHEET A6: SPECIFY OVERFLOW DRAINS OR SCUPPERS AS
 REQUIRED BY SEC. R903.4.1.
  
 10- SHEET A7: SPECIFY OVERFLOW DRAINS OR SCUPPERS AS
 REQUIRED BY SEC. R903.4.1.
  
 11- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE ROOF VENTILATION SEC. R806.
 NOTE: COORDINATE WITH-THE ENERGY CALCULATIONS.
  
 12- SHEET A10: STAIR RAILING DETAIL DOESN'T MATCH
 PLANS. REVISE AS REQUIRED. SEC. 107.2.1 CITY
 AMENDMENTS.
 NOTE: PROVIDE COMPLETE STAIRWAY AND RAILING SYSTEM
 SPECIFICATIONS, REVIEWED BY THE DESIGNER OF RECORD.
 THIS MAY BE SUBMITTED LATER AS A PROVISO PRIOR TO
 INSTALLATION.
  
 13- PROVIDE ICC EVALUATION REPORT FOR THE SPRAY
 INSULATION SPECIFIED ON PLANS. SEC. R316.
  
 14- SHEET A14: REVISE WINDOW DETAILS THAT SHOW BEVELED
 BUCK. NEED TO SHOW BUCKS THAT PROVIDE FULL SUPPORT TO
 THE WINDOW FRAME AS REQUIRED BY SEC. R612.7.2.1.
  
 15- REVISE ENERGY CALCULATIONS SUBMITTED:
 A) NEED TO USE CURRENT FORM FBC- ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 B) JURISDICTION NUMBER DOESN'T CORRESPOND TO CITY OF
 WEST PALM BEACH AND THE PERMIT OFFICE IS NOT PALM
 BEACH. ALSO, PROVIDE THE OWNER AND BUILDER INFORMATION.
 SEC. R101.5.1.1.2 OF FBC- ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
 C) CONDITIONED FLOOR AREA DOESN'T MATCH PLANS. SEC.
 R101.5.1.1.2 OF FBC- ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 D) PROVIDE THE NAME OF THE INDIVIDUAL COMPLETING THE
 REPORT AS REQUIRED BY SEC. R405.4.2 OF FBC- ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 E) ROOF INFORMATION ON PAGE 3 OF 7: REVISE ROOF TYPE
 AND MATERIALS TO MATCH PLANS. PLANS SHOW MODIFIED
 BITUMEN AND METAL ROOF. SEC. R101.5.1.1.2 OF FBC-
 ENERGY CONSERVATION, 5TH EDITION (2014).
  
 F) CEILING INFORMATION ON PAGE 3 OF 7: R VALUE TO MATCH
 PLANS AND PAGE 1 OF 7. SEC. R101.5.1.1.2 OF FBC- ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 G) WINDOWS ON PAGE 4 OF 7: REVISE OVERHANG DEPTH AND
 SEPARATION TO MATCH PLANS. SEC. R101.5.1.1.2 OF FBC-
 ENERGY CONSERVATION, 5TH EDITION (2014).
  
 H ) PROVIDE WINDOWS AND DOORS MANUFACTURER'S SPECS
 SHOWING COMPLIANCE WITH THE U-FACTOR AND SHGC FACTOR
 SPECIFIED ON ITEM #7 AS REQUIRED BY SEC. R405.4.3 OF
 FBC- ENERGY CONSERVATION, 5TH EDITION (2014).
  
 16- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) CUSTOM ENTRY DOOR AS SHOWN ON PLANS. PROVIDE
 COMPLETE ENGINEERING PACKAGE FOR BUILDING OFFICIAL
 APPROVAL. CONTACT BROWN AT [email protected].
  
 B) 18'-0" OVERHEAD GARAGE DOOR THAT MEETS THE DESIGN
 PRESSURES CALCULATED BY THE ENGINEER OF RECORD. NOA
 15-0317.01 SUBMITTED DOESN'T MEET THE DESIGN PRESSURES.
  
 C) STOREFRONT SYSTEM WITH WINDOW SIZES AS SHOWN ON
 PLANS. SEE WINDOWS W02, W04 AND W05. NOA 12-1005.01
 SUBMITTED DOESN'T COVER THOSE SIZES.
  
 D) SLIDING GLASS DOOR #D10 WITH SIZE AS SHOWN ON PLANS.
 NOA 12-0130.13 SUBMITTED DOESN'T COVER THIS SIZE.
 MAXIMUM PANEL SIZE FOR A 10'-0" HIGH DOOR IS 48".
  
 E) CASEMENT WINDOW #W12 AS SHOWN ON PLANS. THERE
 WINDOWS MULLED TOGETHER.
  
 F) DOOR #D07 AS SHOWN ON PLANS. SEE SIZE AND DOOR WITH
 FIXED SIDELITES ASSEMBLY.
  
 G) STEEL PANEL WALL SYSTEM AS SHOWN ON PLANS.
  
 H) 14" EXHAUST AIR GRILLS AS SHOWN ON PLANS.
  
 I) METAL ROOF AS SHOWN ON PLANS.
  
 J) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON
 PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN
 PRESSURES.
  
 K) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 L) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. PROVIDE FLORIDA PRODUCT APPROVAL COVER
 PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR LIST
 THE FLORIDA PRODUCT APPROVAL NUMBER NEXT TO THE
 SPECIFIED CONNECTOR.
  
 17- DESIGNER OF RECORD TO APPROVE IN WRITING (NOT
 SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 18- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 FINISH COVERING OF THE SECOND FLOOR COVERED TERRACE.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 19- NOTE: PRIOR TO FABRICATION AND INSTALLATION PROVIDE
 COMPLETE ENGINEER PACKAGE FOR THE BAR JOIST AND
 CONCRETE DECK SYSTEMS, STAIRWAY , HANDRAILS AND
 GUARDRAILS APPROVED BY THE DESIGNER OF RECORD.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING.
 SUBMIT OLD COPIES FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
2015-07-24 14:31:31 
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2015-12-10 Cont ID  
Sent By mvaldes Date 2015-12-10 Time 09:06 Rev Time 0.00
Received By mvaldes Date 2015-12-10 Time 09:05 Sent To  
Notes
2015-12-10 09:07:531ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 PHIL PETTY
 561-805-6742
 [email protected]
  
  
 240.4 PROTECTION OF CONDUCTORS. CONDUCTORS, OTHER THAN
 FLEXIBLE CORDS, FLEXIBLE CABLES, AND FIXTURE WIRES,
 SHALL BE
 PROTECTED AGAINST OVERCURRENT IN ACCORDANCE WITH THEIR
 AMPACITIES
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2015-12-02 Cont ID  
Sent By mvaldes Date 2015-12-02 Time 16:07 Rev Time 0.00
Received By mvaldes Date 2015-12-02 Time 16:07 Sent To  
Notes
2015-12-02 16:26:031ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 PHIL PETTY
 561-805-6742
 [email protected]
  
  
  
  
 1- WRONG GEC SIZE FOR SERVICE PLEASE TAKE A LOOK AT
 TABLE 250.66 NEC
 2- WRONG OVERCURRENT DEVICE FOR DISCONNECT B AND C
 240.4 PROTECTION OF CONDUCTORS. CONDUCTORS, OTHER THAN
 FLEXIBLE CORDS, FLEXIBLE CABLES, AND FIXTURE WIRES,
 SHALL BE
 PROTECTED AGAINST OVERCURRENT IN ACCORDANCE WITH THEIR
 AMPACITIES
 SPECIFIED IN 310.15
 3-AC DISCONNECTS NOT DRAWN READILY ACCESIBLE
 440.14 LOCATION. DISCONNECTING MEANS SHALL BE LOCATED
 WITHIN SIGHT FROM AND READILY ACCESSIBLE FROM THE
 AIRCONDITIONING
 OR REFRIGERATING EQUIPMENT.
 4-FIRST FLOOR ELECTRICAL PLAN SHOWS SWITCH INSIDE A
 DOOR OPENNIG ( TYPO)
 5-POOL EQUIPMENT DOESN'T SHOW GFCI PROTECTION
 440.14 LOCATION. DISCONNECTING MEANS SHALL BE LOCATED
 WITHIN SIGHT FROM AND READILY ACCESSIBLE FROM THE
 AIRCONDITIONING
 OR REFRIGERATING EQUIPMENT.
 6-ISLAND RECEPTACLES DOESN'T SHOW GFCI PROTECTION ?
 7-RECESSD LIGHTS ARE NOT SHOWN TO BE IC RATED ?
 8-PLEASE PROVIDE MOUNTING DETAIL FOR FLOURESECENT
 FIXTURES ON FIRST FLOOR GARAGE.
 9-PLEASE PROVIDE MANUFACTURE SPECS FOR CAR LIFTS AND
 ELEVATOR EQUIPMENT.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-11-15 Cont ID  
Sent By skennedy Date 2015-11-15 Time 12:08 Rev Time 0.00
Received By skennedy Date 2015-11-15 Time 12:08 Sent To  
Notes
2015-11-15 12:09:15REVIEW BY PPETTY

Review Stop E ELECTRICAL
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By ppetty Date 2015-08-26 Time 09:32 Sent To  
Notes
2015-08-26 09:37:38250.64 CHECK GEC SIZE
 MAIN TAPS AT METER NOT TO FPL SERVICE STANDARDS
 PHIL 561-644-7305

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2015-11-12 Cont ID  
Sent By cranford Date 2015-11-12 Time 13:56 Rev Time 0.00
Received By cranford Date 2015-11-12 Time 13:56 Sent To  
Notes
2015-11-12 13:56:36CALCULATIONS ADDED TO C-1, DATED 10/2/2015

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2015-09-01 Cont ID  
Sent By cranford Date 2015-09-01 Time 14:38 Rev Time 0.00
Received By cranford Date 2015-09-01 Time 11:49 Sent To M
Notes
2015-09-01 14:37:34PLEASE SHOW LOCATIONS AND SIZES OF PROPOSED POTABLE
 WATER AND SANITARY SEWER SERVICES.
  
 EXISTING STORM SYSTEM ALONG THE PROPERTY'S SOUTHERN
 PROPERTY LINE WILL BE REMOVED AND REPLACED BY THE
 CITY'S RUTLAND BLVD IMPROVEMENTS PROJECT. PLEASE
 CONTACT TRACY WARD, PE TO DISCUSS THE FEASIBILITY OF
 DIRECTLY OR INDIRECTLY CONNECTING TO THE NEW SYSTEM.
 (561) 494-1120.
  
 THE SUBMITTED SURVEY HAS INCORRECTLY LABELED THE
 RUTLAND BLVD CUL-DE-SAC AS FLAGLER AVENUE.
  
 PLEASE SUBMIT SIGNED AND SEALED CALCULATIONS FOR THE
 PROPOSED EXFITLRATION TRENCH.
  
 PLEASE SHOW A DETAIL OF THE PROPOSED RETAINING WALL AND
 THE FOOTER PROXIMITY TO THE PROPERTY LINE.
  
 THE PROPOSED CONSTRUCTION FALLS WITHIN ZONE A5 OF THE
 LAKE WORTH LAGOON, WITH A BASE FLOOD ELEVATION OF 7.0
 NGVD. PLEASE VERIFY RAISING THE GROUND ELEVATION ABOVE
 THE FLOOD ELEVATION WILL ALLOW THE EXISTING SHEETFLOW
 TO CONTINUE TO REACH THE LAGOON. TYPICALLY, BROAD FLAT
 AREAS A LEFT FOR THIS FLOW PATH RATHER THAN NARROW
 V-SHAPED AREAS.
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)
  
  
  
2015-08-31 11:57:22SEE CIVIL DRAWINGS SUBMITTED.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-12-15 Cont ID  
Sent By jgomez Date 2015-12-15 Time 08:53 Rev Time 0.00
Received By jgomez Date 2015-12-10 Time 09:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-12-04 Cont ID  
Sent By jgomez Date 2015-12-04 Time 18:20 Rev Time 0.00
Received By jgomez Date 2015-11-20 Time 11:46 Sent To  
Notes
2015-11-23 11:46:41R27

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-11-15 Cont ID  
Sent By skennedy Date 2015-11-15 Time 12:09 Rev Time 0.00
Received By skennedy Date 2015-10-14 Time 14:11 Sent To  
Notes
2015-10-14 14:12:11R31

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-11 Cont ID  
Sent By ccole Date 2015-09-11 Time 17:16 Rev Time 0.00
Received By ccole Date 2015-06-30 Time 15:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2015-12-15 Cont ID  
Sent By jgomez Date 2015-12-15 Time 08:50 Rev Time 0.00
Received By jgomez Date 2015-12-15 Time 08:50 Sent To  
Notes
2015-12-15 08:51:16NO FEES. MU-2015-028620.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-11-03 Cont ID  
Sent By jgomez Date 2015-11-03 Time 15:41 Rev Time 0.00
Received By jgomez Date 2015-11-03 Time 15:41 Sent To  
Notes
2015-11-03 15:41:181-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-08-28 Cont ID  
Sent By jgomez Date 2015-08-28 Time 08:36 Rev Time 0.00
Received By jgomez Date 2015-08-28 Time 08:36 Sent To  
Notes
2015-08-28 08:36:291-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-12-03 Cont ID  
Sent By ccole Date 2015-12-03 Time 07:16 Rev Time 0.00
Received By ccole Date 2015-12-03 Time 07:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-10-28 Cont ID  
Sent By ccole Date 2015-10-28 Time 11:40 Rev Time 0.00
Received By ccole Date 2015-10-28 Time 11:41 Sent To  
Notes
2015-10-28 12:18:572ND REVIEW: FBC 2014 MECHANICAL
 PERMIT #15061466
 10/28/15
  
 SOME OF THE COMMENTS FROM THE 1ST REVIEW HAVE NOT BEEN
 COMPLETELY ADDRESSED ON THE PLANS. I AM REPRINTING
 THOSE COMMENTS IN THIS REVIEW.
 PLEASE PROVIDE:
 1-D) AIR DISTRIBUTION SCHEDULE INDICATING MAKES,
 MODELS, AND DIMENSIONS OF DIFFUSERS AND GRILLS.
 1-E) AC DUCT CONNECTION, SUPPORT AND HANGING DETAILS
 1-I) VERIFICATION OF CONDENSER INSTALLATION AT OR ABOVE
 THE BASE FLOOD ELEVATION HEIGHT- SEE SECTION R322.1.6
 FBC-14 RESIDENTIAL.
 5) PROVIDE SIZING CALCULATIONS FOR THE EXHAUST
 VENTILATION SYSTEMS SHOWN IN THE THE GARAGE, BIKE SHOP,
 AND STORAGE AREA ON THE 1ST FLOOR.
 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE CARBON
 MONOXIDE DETECTORS AND INDICATE THEIR EXACT
 INSTALLATION LOCATIONS ON THE PLAN (SPACINGS, HEIGHT
 AFF).
 7) SUBMIT FL. PRODUCT APPROVALS OR MIAMI-DADE NOA'S FOR
 THE EXHAUST AND MAKE UP AIR LOUVERS.
 8) THE U-FACTORS SHOWN ON THE ENERGY CALCULATIONS FOR
 THE WINDOWS DO NOT MATCH THE VALUES LISTED ON THE AC
 CALCULATIONS.
 9) THE OVERHEAD DOORS IN THE MAIN GARAGE AND STORAGE 3
 ARE INDICATED AS WOOD DOORS ON THE ENERGY CALCS,
 HOWEVER THE NOA SUBMITTED FROM AMARR SHOWS THEM TO BE
 STEEL. ALSO NO DATA IS SHOWN ON THE CALCS FOR THE MAN
 DOOR IN THE GARAGE.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-09-11 Cont ID  
Sent By ccole Date 2015-09-11 Time 16:26 Rev Time 0.00
Received By ccole Date 2015-09-11 Time 16:26 Sent To  
Notes
2015-09-11 16:28:341ST REVIEW: FBC 2014 RESIDENTIAL
 PERMIT #15061466
 9/11/15
  
 1) SUBMIT COMPLETE MECHANICAL PLANS, DETAILS, AND
 SPECIFICATIONS FOR REVIEW INCLUDING:
 A) AC DUCT LAYOUT PLANS FOR EACH NEW SYSTEM INDICATING
 THE TYPES AND SIZES OF DUCTS, SUPPLY CFM'S AT EACH
 DIFFUSER, MEANS OF RETURN AIR INCLUDING DIMENSIONS OF
 RETURN AIR GRILLS, TRANSFER GRILLS, AND RETURN CFM'S.
 REFER TO SECTION M1602.2 FOR PROHIBITED RETURN AIR
 SOURCES.
 B) AC EQUIPMENT SCHEDULES LISTING THE MAKES AND MODELS
 OF ALL COMPONENTS, COOLING AND HEATING CAPACITIES,
 EFFICIENCY RATINGS, ELECTRICAL DATA ETC.
 C) AHRI CERTIFICATES FOR EACH NEW SYSTEM.
 D) AIR DISTRIBUTION SCHEDULE INDICATING MAKES, MODELS,
 AND DIMENSIONS OF DIFFUSERS AND GRILLS.
 E) AC DUCT CONNECTION, SUPPORT AND HANGING DETAILS
 F) DIMENSIONED PLAN AND SECTION VIEWS OF THE AIR
 HANDLER CLOSET INDICATING COMPLIANCE WITH SECTION
 M1305.1.1 FBC-14 RESIDENTIAL, AND SECTION C403.2.7.2
 FBC-14 ENERGY CONSERVATION- SHOW THE MEANS OF RETURN
 AIR TO EACH UNIT IN THE CLOSET.
 G) CONDENSATE DISPOSAL PLANS- PRIMARY AND SECONDARY FOR
 EACH NEW AIR HANDLER- SEE SECTION M1411.3 RESIDENTIAL.
 H) WIND LOAD TIE DOWN ENGINEERING FOR MOUNTING THE AC
 CONDENSERS TO THE NEW PADS- SEE SECTIONS M1305.1.4.1 &
 M1307.2 FBC-14 RESIDENTIAL
 I) VERIFICATION OF CONDENSER INSTALLATION AT OR ABOVE
 THE BASE FLOOD ELEVATION HEIGHT- SEE SECTION R322.1.6
 FBC-14 RESIDENTIAL.
 2) PROVIDE BATHROOM EXHAUST DETAILS: EXHAUST FAN
 EQUIPMENT SCHEDULES, EXHAUST DUCT RUNS AND TERMINATION
 LOCATIONS.
 3) PROVIDE DRYER EXHAUST AND MAKEUP AIR PLANS PER
 SECTION M1502: SHOW THE TYPE AND SIZE OF EXHAUST DUCT,
 EXHAUST DUCT RUN LENGTH AND TERMINATION LOCATION, AND
 INDICATE HOW MAKEUP AIR WILL BE SUPPLIED TO EACH DRYER.
 SUBMIT MANUFACTURER'S SPECS FOR THE APPLIANCES.
 4) REFER TO SECTION M1503 AND PROVIDE KITCHEN EXHAUST
 VENTILATION PLANS.
 5) PROVIDE SIZING CALCULATIONS FOR THE EXHAUST
 VENTILATION SYSTEMS SHOWN IN THE THE GARAGE, BIKE SHOP,
 AND STORAGE AREA ON THE1ST FLOOR.
 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE CARBON
 MONOXIDE DETECTORS AND INDICATE THEIR EXACT
 INSTALLATION LOCATIONS ON THE PLAN (SPACINGS, HEIGHT
 AFF).
 7) SUBMIT MANUFACTURER'S SPECIFICATIONS AND FL. PRODUCT
 APPROVALS FOR THE EXHAUST AND MAKE UP AIR FANS AND
 LOUVERS. PROVIDE FAN SCHEDULES ON THE PLANS INDICATING
 THEIR CFM CAPACITIES, ELECTRICAL DATA ETC.
 PLEASE NOTE ADDITIONAL COMMENTS MAY FOLLOW SUBMITTAL OF
 REVISED PLANS AND RESPONSES TO ALL BUILDING DEPARTMENT
 COMMENTS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2016-03-23 Cont ID  
Sent By shill Date 2016-03-23 Time 11:27 Rev Time 0.00
Received By shill Date 2016-03-23 Time 11:27 Sent To  
Notes
2016-03-23 11:51:33****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE LATITUDE / LONGITUDE IS NOT THE SAME AS ON THE
 EC PROVIDED AT TIME OF PLAN REVIEW. IT APPEARS TO BE
 THE COORDINATES FOR ANOTHER LOCATION (1902 NOTRE DAME
 DR, LAKE WORTH), PLEASE REVISE OR EXPLAIN. PER EC
 INSTRUCTIONS, THE LAT/LONG IS TO BE ACCURATE WITHIN
 66'.
  
 2. BUILDING TYPE IS 1A, WHICH IS SLAB ON GRADE, BUT
 LINE A8 A SHOWS 3913.5 SF IN CRAWLSPACE, PLEASE REVISE
 OR EXPLAIN. THIS IS ALSO NOT CONSISTENT WITH THE
 "CONSTRUCTION DRAWINGS" ELEVATION CERTIFICATE OR THE
 PERMIT DOCUMENTS.
  
 3. THE LEGAL OWNER OF RECORD IS SOPHIE SHARP, PLEASE
 REVISE.
  
 4. AN EXPIRED ELEVATION CERTIFICATE FORM WAS USED. THE
 NEW ELEVATION CERTIFICATE WHICH EXPIRES NOV 30, 2018 IS
 TO BE USED. IT CAN BE FOUND HERE:
  
 HTTP://NFIPISERVICE.COM/STAKEHOLDER/W_16002/W-16002.HTM
 L
  
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status P Date 2015-12-07 Cont ID  
Sent By jgomez Date 2015-08-31 Time 13:32 Rev Time 0.00
Received By shill Date 2015-08-31 Time 13:32 Sent To  
Notes
2015-12-03 18:28:24***ELEVATION CERTIFICATE REQUIRED***
  
  
 12/3/15 CALLED MR. GRUBER, CIVIL ENGINEER FOR THE
 PROJECT, TO DISCUSS THE PROPOSED NFIP MAP, ADVISED TO
 INVESTIGATE FUTURE BFE PRIOR TO COMMENCEMENT.
  
 PROPOSED CONSTRUCTION COMPLIES WITH CURRENT
 REQUIREMENTS. FINAL FUTURE NFIP MAP IS NOT AVAILABLE AT
 THIS TIME.
  
  
  
  
2015-08-31 13:33:40PLEASE NOTIFY SAMANTHA HILL WHEN PERMIT IS ISSUED.

Review Stop P PLUMBING
Rev No 3 Status P Date 2015-12-01 Cont ID  
Sent By tklarge Date 2015-12-01 Time 06:14 Rev Time 0.00
Received By tklarge Date 2015-11-30 Time 09:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-10-21 Cont ID  
Sent By gjohnson Date 2015-10-21 Time 13:59 Rev Time 0.00
Received By gjohnson Date 2015-10-21 Time 13:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-07-27 Cont ID  
Sent By gjohnson Date 2015-07-27 Time 15:41 Rev Time 0.00
Received By gjohnson Date 2015-07-23 Time 16:35 Sent To  
Notes
2015-07-27 15:43:06 
 1. GARAGE SHOWS AUTOMOBILE LIFT AND ELECTRICAL BOXES
 NOTED AS "CAR EQUIPMENT" AN AIR COMPRESSOR, CARBON
 MONOXIDE SENSOR , ETC. THIS HAS ALL THE APPEARANCE OF A
 VEHICLE REPAIR FACILITY. WHICH FALLS UNDER AN S-1
 OCCUPANCY AND THE 2014 BC PLUMBING CODE.
  
 2A. WHERE ARE THE FLOOR DRAINS TERMINATING
 2B.AN OIL SEPARATOR IS REQUIRED PER 2014 FBC P 1003.4
 AND SHALL COMPLY WITH FBC P SEC. 1003.4.1 THRU
 1003.4.2.2 FLOOR DRAINS MUST DISCHARGE THRU OIL
 SEPARATOR.
  
 3.DOWNSPOUTS SHALL BE SIZED IN ACCORDANCE WITH 2014 FBC
 P TABLE 1106.2[2] SHEET A-9 INDICATE SIZE OF DOWNSPOUTS
 SQ FT. BEING DRAINED BY EACH DOWNSPOUT BASED ON 5IN.
 RAINFALL RATIO 1/2 THE AREA OF ANY VERTICAL THAT
 CONNECTS TO ROOF SHALL BE CALCULATED IN TH SQ. FT.
 CALCULATIONS.
  
 4.PLEASE INDICATE ON THE PLAN IF THE ELEVATOR IS
 TRACTION TYPE OR HYDRAULIC IF HYDRAULIC PIT MUST DRAIN
 THRU OIL SEPARATOR FBC 10004.3.
  
 5.SUBMIT POTABLE WATER RISER. PER WPB AMENDMENTS TO FBC
 2010 107.3.5.2
  
 6. INDICATE ON THE PLAN IF ANY COMPRESSED AIR PIPING
 WILL BE INSTALLED, IF SO SUBMIT A RISER DIAGRAM FOR AIR
 PIPING SHOW SUPPORT,SIZINGS TYPE OF PIPE USED ,VALVES
 AND OUTLETS ETC.
  
 7.SHEET A-10 BLDG. SEC A-A SHOWS HYDRAULIC LIFT PIT
 WITH TWO DRAIN PIPES WHAT IS THE USE OF THESE LINES
 ,ARE THEY PERFORATED PLEASE CLARIFY.
  
  
  
  
  
 1ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 561-805-6711
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2015-12-15 Cont ID  
Sent By jgomez Date 2015-12-15 Time 08:57 Rev Time 0.00
Received By jgomez Date 2015-12-15 Time 08:57 Sent To  
Notes
2015-12-15 08:59:21PROVISO:
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) METAL ROOF AS SHOWN ON PLANS.
  
 B) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON
 PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN
 PRESSURES.
  
 C) PROVIDE COMPLETE DETAILS, SPECIFICATIONS AND PRODUCT
 APPROVAL FOR THE FINISH COVERING UNDERLAYMENT OF THE
 SECOND FLOOR COVERED TERRACE. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 2- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
 NOTE: PLEASE PLACE THE REVIEW STAMP ON THE FRONT OF THE
 PRODUCT APPROVAL COVER PAGE NOT ON THE BACK (OR ON ANY
 OTHER FRONT PAGE WHERE THERE IS ENOUGH ROOM FOR THE
 STAMP). SCANNING DOCUMENTS FOR RECORD KEEPING IS NOT
 ADEQUATE WHEN STAMPS ARE ON THE BACK OF THE PAGE.
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2015-12-04 Cont ID  
Sent By jgomez Date 2015-12-04 Time 18:20 Rev Time 0.00
Received By jgomez Date 2015-12-04 Time 18:20 Sent To  
Notes
2015-12-04 18:24:52 
 NOTE:
 COMMENTS BELOW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS TO ISSUE PERMIT AND REVISED PLANS ADDRESSING THE
 COMMENTS WILL BE SUBMITTED LATER. FEES MAY APPLY. NEED
 CONTRACTOR'S APPROVAL TO GO AHEAD WITH THE PROVISO
 OPTION. BUT, BEFORE ISSUING THE PERMIT, ALL THE
 STRUCTURAL DRAWINGS NEED TO BE RE-SUBMITTED WITHOUT THE
 "NOT FOR CONSTRUCTION" NOTE.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) METAL ROOF AS SHOWN ON PLANS.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 B) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON
 PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN
 PRESSURES.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 C) PROVIDE COMPLETE DETAILS, SPECIFICATIONS AND PRODUCT
 APPROVAL FOR THE FINISH COVERING UNDERLAYMENT OF THE
 SECOND FLOOR COVERED TERRACE. SEC. 107.2.1 CITY
 AMENDMENTS.
 RESPONSE: TO BE SUBMITTED LATER. OK.
  
 2- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
 NOTE: PLEASE PLACE THE REVIEW STAMP ON THE FRONT OF THE
 PRODUCT APPROVAL COVER PAGE NOT ON THE BACK (OR ON ANY
 OTHER FRONT PAGE WHERE THERE IS ENOUGH ROOM FOR THE
 STAMP). SCANNING DOCUMENTS FOR RECORD KEEPING IS NOT
 ADEQUATE WHEN STAMPS ARE ON THE BACK OF THE PAGE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2015-08-31 Cont ID  
Sent By jgomez Date 2015-08-31 Time 15:19 Rev Time 0.00
Received By jgomez Date 2015-08-31 Time 12:56 Sent To  
Notes
2015-08-31 15:21:111- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) METAL ROOF AS SHOWN ON PLANS.
  
 B) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON
 PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN
 PRESSURES.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2015-12-03 Cont ID  
Sent By sgraham Date 2015-12-03 Time 09:02 Rev Time 0.00
Received By sgraham Date 2015-12-03 Time 09:02 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2015-10-22 Cont ID  
Sent By sgraham Date 2015-10-22 Time   Rev Time 0.00
Received By   Date 2015-10-22 Time   Sent To  
Notes
2015-10-22 11:09:052ND CHECKLIST 10/22/15
  
 1. THE LIFT WILL NOT BE PERMITTED IN THE SF7 ZONING
 DISTRICT AS PER ANGELLA VANN, ZONING ADMINISTRATOR.
  
 2. THE MAX HEIGHT IN SF7 ZONING IS 30' FEET, YOU HAVE
 LEVELS SOME ARE 32' FEET AND 34' FEET, YOU MUST MEASURE
 FROM GRADE TO THE ROOF MEAN.

Review Stop Z ZONING
Rev No 1 Status F Date 2015-08-10 Cont ID  
Sent By sgraham Date 2015-08-10 Time 14:40 Rev Time  
Received By sgraham Date   Time   Sent To  
Notes
2015-08-10 14:44:528/10/15 ZONING FAILED
  
 1. AUTOMOBILE LIFTS ARE NOT ALLOWED IN SF7 ZONING, THIS
 IS COMMERICAL EQUIPMENT.
 2. THE MAXIMUM HEIGHT IN SF7 IS 30' FEET, YOU HAVE
 DIFFERENGT LEVELS, SOME ARE 32' AND 34' FEET, MEASURING
 THE ROOF MEAN