| Plan Review Stops For Permit 15061466 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-15 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-15 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2015-12-15 08:27:56 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: | | | A) CUSTOM ENTRY DOOR AS SHOWN ON PLANS. PROVIDE | | | COMPLETE ENGINEERING PACKAGE FOR BUILDING OFFICIAL | | | APPROVAL. CONTACT BROWN AT [email protected]. | | | B) STEEL PANEL WALL SYSTEM AS SHOWN ON PLANS. | | | C) METAL ROOF AS SHOWN ON PLANS. | | | D) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON | | | PLANS. | | | E) PROVIDE COMPLETE DETAILS, SPECIFICATIONS AND PRODUCT | | | APPROVAL FOR THE FINISH COVERING UNDERLAYMENT OF THE | | | SECOND FLOOR COVERED TERRACE. | | | 3- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | | APPROVALS. | | | 4- PRIOR TO FABRICATION AND INSTALLATION PROVIDE | | | COMPLETE ENGINEER PACKAGE FOR THE BAR JOIST AND | | | CONCRETE DECK SYSTEMS, STAIRWAY , HANDRAILS AND | | | GUARDRAILS APPROVED BY THE DESIGNER OF RECORD. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-12-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-03 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-03 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2015-12-03 17:48:19 | | | | NOTE: | | | COMMENTS BELOW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS TO ISSUE PERMIT AND REVISED PLANS ADDRESSING THE | | | COMMENTS WILL BE SUBMITTED LATER. FEES MAY APPLY. NEED | | | CONTRACTOR'S APPROVAL TO GO AHEAD WITH THE PROVISO | | | OPTION. BUT, BEFORE ISSUING THE PERMIT, ALL THE | | | STRUCTURAL DRAWINGS NEED TO BE RE-SUBMITTED WITHOUT THE | | | "NOT FOR CONSTRUCTION" NOTE. | | | | | | 1- REVISED SOIL TEST REPORT NEEDS THE ENGINEER'S | | | ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471 | | | F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS. | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) CUSTOM ENTRY DOOR AS SHOWN ON PLANS. PROVIDE | | | COMPLETE ENGINEERING PACKAGE FOR BUILDING OFFICIAL | | | APPROVAL. CONTACT BROWN AT [email protected]. | | | RESPONSE: IT WILL BE SUBMITTED AT A FUTURE DATE PRIOR | | | TO INSTALLATION. OK. | | | | | | B) STEEL PANEL WALL SYSTEM AS SHOWN ON PLANS. | | | RESPONSE: WILL BE SUBMITTED LATER. OK. | | | | | | C) METAL ROOF AS SHOWN ON PLANS. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | D) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON | | | PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND | | | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF | | | SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN | | | PRESSURES. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | E) PROVIDE COMPLETE DETAILS, SPECIFICATIONS AND PRODUCT | | | APPROVAL FOR THE FINISH COVERING UNDERLAYMENT OF THE | | | SECOND FLOOR COVERED TERRACE. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | 3- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | NOTE: PLEASE PLACE THE REVIEW STAMP ON THE FRONT OF THE | | | PRODUCT APPROVAL COVER PAGE NOT ON THE BACK (OR ON ANY | | | OTHER FRONT PAGE WHERE THERE IS ENOUGH ROOM FOR THE | | | STAMP). SCANNING DOCUMENTS FOR RECORD KEEPING IS NOT | | | ADEQUATE WHEN STAMPS ARE ON THE BACK OF THE PAGE. | | | | | | 4- PRIOR TO FABRICATION AND INSTALLATION PROVIDE | | | COMPLETE ENGINEER PACKAGE FOR THE BAR JOIST AND | | | CONCRETE DECK SYSTEMS, STAIRWAY , HANDRAILS AND | | | GUARDRAILS APPROVED BY THE DESIGNER OF RECORD. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING. | | | SUBMIT OLD COPIES FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-11-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-03 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-03 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2015-11-03 15:27:58 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC-RESIDENTIAL -5TH EDITION(2014. | | | | | | 1- THE 2014 BC TOOK EFFECT ON JUNE 30TH, 2015. PERMIT | | | APPLICATION WAS SUBMITTED ON JUNE 30TH. BUILDING REVIEW | | | WILL BE DONE BASED ON THE NEW CODE. PLEASE UPDATE ALL | | | PLANS AND NOTES AS REQUIRED. | | | RESPONSE: SHEET A0 WAS NOT REVISED. STILL REFERENCING | | | THE 2010 CODE. | | | | | | 2- ARCHITECTURAL PLANS TITLE BLOCK IS MISSING ALL THE | | | INFORMATION OF THE ARCHITECT WHO IS SIGNING AND SEALING | | | THE PLANS AS REQUIRED BY FAC 61G1-16.004. | | | RESPONSE: TITLE BLOCK WAS NOT REVISED. THE ARCHITECT'S | | | REQUIRED INFORMATION STILL NO PROVIDED. | | | | | | 3- A) SOIL TEST REPORT SUBMITTED: PROJECT DESCRIPTION | | | DOESN'T MATCH PROPOSED CONSTRUCTION. BUILDING AREA IS | | | SIGNIFICANTLY HIGHER AND THE TYPE OF PROPOSED | | | CONSTRUCTION NEEDS ATTENTION TOO. REVISE REPORT AS | | | REQUIRED. SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION | | | (2014). | | | | | | B) ENGINEER OF RECORD TO REVIEW REVISED SOIL TEST | | | REPORT BASED ON THE ACTUAL PROPOSED CONSTRUCTION AND | | | SQUARE FOOTAGE. AND, ACKNOWLEDGE IN WRITING TO THIS | | | OFFICE THAT GEOTECHNICAL FOUNDATION RECOMMENDATIONS | | | WERE ADOPTED IN THE DESIGN, INCLUDING THE | | | RECOMMENDATION TO STRUCTURALLY SEPARATE FOOTING AND | | | COLUMNS FROM THE FLOOR SLAB. OTHERWISE, PROVIDE | | | ENGINEERING ANALYSIS FOR PROPOSED FOOTING DESIGN SHOWN | | | ON PLANS. SEC. 107.2.1.3 CITY AMENDMENTS. | | | | | | 4- NEW ELEVATOR/FLOOD ZONE NOTE ON SHEET A6: CODE SEC. | | | R1403.5. & 6 SPECIFIED ON NOTE #1 DOESN'T EXIST ON THE | | | 2014 CODE AND DOESN'T APPLY TO ELEVATOR EQUIPMENT. | | | REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 5- REVISE FOUNDATION PLAN ON SHEET S1 TO MATCH REVISED | | | ARCHITECTURAL PLAN SHOWING LANDING FROM THE CLUB ROOM | | | TO THE COVERED LANAI AS REQUIRED BY SEC. R311.3 OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | 6- PROVIDE DETAILS AND SPECIFICATIONS FOR THE DESIGN OF | | | THE STRUCTURAL SUPPORTS OF THE ELEVATOR AS REQUIRED BY | | | ELEVATOR SPECS SUBMITTED AND SEC. R301 FBC-RESIDENTIAL, | | | 5TH EDITION (2014). | | | | | | 7- PROVIDE COMPLIANCE WITH THE ACCESSIBILITY SEC. R320. | | | RESPONSE: 2'-6" DOORS DON'T PROVIDE 29" CLEAR OPENING. | | | | | | 8- SHEET A6: SPECIFY OVERFLOW DRAINS OR SCUPPERS AS | | | REQUIRED BY SEC. R903.4.1. | | | RESPONSE: OVERFLOW DRAINS WERE NOT SPECIFIED. THESE ARE | | | ADDITIONAL TO THE REGULAR FLOOR DRAINS. SEE SEC. R903.1 | | | | | | 9- SHEET A7: SPECIFY OVERFLOW DRAINS OR SCUPPERS AS | | | REQUIRED BY SEC. R903.4.1. | | | RESPONSE: OVERFLOW DRAINS WERE NOT SPECIFIED. THESE ARE | | | ADDITIONAL TO THE REGULAR FLOOR DRAINS. SEE SEC. R903.1 | | | | | | 10- PROVIDE ICC EVALUATION REPORT FOR THE SPRAY | | | INSULATION SPECIFIED ON PLANS. SEC. R316. | | | RESPONSE: EVALUATION REPORT ESR-1826 SUBMITTED EXPIRED | | | ON FEBRUARY 1, 2015. NEED CURRENT ONE. REMAINDER: AND, | | | ARCHITECT TO APPROVE PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 11- REVISE ENERGY CALCULATIONS SUBMITTED: | | | A) ROOF INFORMATION ON PAGE 3 OF 7: REVISE ROOF TYPE | | | AND MATERIALS TO MATCH PLANS. PLANS SHOW MODIFIED | | | BITUMEN AND METAL ROOF. SEC. R101.5.1.1.2 OF FBC- | | | ENERGY CONSERVATION, 5TH EDITION (2014). | | | RESPONSE: INFORMATION IS INCORRECT. THE FLAT ROOF IS | | | NOT METAL. THE FLAT ROOF IS MODIFIED BITUMEN AND THERE | | | IS A PITCHED ROOF WITH METAL ROOF. SEE PLANS AND REVISE | | | AS REQUIRED. | | | | | | B) CEILING INFORMATION ON PAGE 3 OF 7: R VALUE TO MATCH | | | PLANS AND PAGE 1 OF 7. SEC. R101.5.1.1.2 OF FBC- ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | RESPONSE: INFORMATION SUBMITTED STILL DOESN'T MATCH. | | | | | | C) OWNER/AGENT TO CERTIFY AND DATE BOTTOM OF FORM AS | | | REQUIRED BY SEC. R103.1.1.2 OF FBC-ENERGY CONSERVATION, | | | 5TH EDITION (2014). | | | | | | D) REVISE THE CLIMATE ZONE ON PAGE 2 OF 6. PALM BEACH | | | IS NOT ZONE 2.. SEE TABLE R301.1 OF FBC- ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | NOTE: | | | LABEL FOR THE WINDOWS AND DOORS SHOWING THE U-FACTOR | | | AND SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS | | | WILL BE REQUIRED WHEN ENERGY CALCULATIONS ARE NOT USING | | | THE DEFAULT FACTOR FOR GLAZING. | | | | | | 12- REVISED HANDRAIL DETAIL TO SHOW COMPLIANCE WITH THE | | | OPENING LIMITATIONS OF THE TRIANGULAR AREA FORMED BY | | | THE TREAD, RISER AND BOTTOM OF RAIL AS REQUIRED SEC. | | | R312.1.3 OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | 13- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) CUSTOM ENTRY DOOR AS SHOWN ON PLANS. PROVIDE | | | COMPLETE ENGINEERING PACKAGE FOR BUILDING OFFICIAL | | | APPROVAL. CONTACT BROWN AT [email protected]. | | | RESPONSE: IT WILL BE SUBMITTED AT A FUTURE DATE PRIOR | | | TO INSTALLATION. OK. | | | | | | B) STEEL PANEL WALL SYSTEM AS SHOWN ON PLANS. | | | RESPONSE: WILL BE SUBMITTED LATER. OK. | | | | | | C) 14" EXHAUST AIR GRILLS AS SHOWN ON PLANS. | | | RESPONSE: PROVIDE THE ACTUAL MIAMI-DADE NOA OR FLORIDA | | | PRODUCT APPROVAL. AND DESIGNER OF RECORD TO APPROVE | | | BEFORE SUBMITTAL TO THIS OFFICE. | | | | | | D) METAL ROOF AS SHOWN ON PLANS. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | E) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON | | | PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND | | | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF | | | SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN | | | PRESSURES. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | 14- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | NOTE: PLEASE PLACE THE REVIEW STAMP ON THE FRONT OF THE | | | PRODUCT APPROVAL COVER PAGE NOT ON THE BACK (OR ON ANY | | | OTHER FRONT PAGE WHERE THERE IS ENOUGH ROOM FOR THE | | | STAMP). SCANNING DOCUMENTS FOR RECORD KEEPING IS NOT | | | ADEQUATE WHEN STAMPS ARE ON THE BACK OF THE PAGE. | | | | | | 15- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | | FINISH COVERING OF THE SECOND FLOOR COVERED TERRACE. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | 16- PRIOR TO FABRICATION AND INSTALLATION PROVIDE | | | COMPLETE ENGINEER PACKAGE FOR THE BAR JOIST AND | | | CONCRETE DECK SYSTEMS, STAIRWAY , HANDRAILS AND | | | GUARDRAILS APPROVED BY THE DESIGNER OF RECORD. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING. | | | SUBMIT OLD COPIES FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-08-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-08-28 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-28 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2015-08-28 08:36:08 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW | | | COMMENTS. | | | CODE: FBC-RESIDENTIAL -5TH EDITION(2014. | | | | | | 1-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY | | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | | CODE. | | | | | | 2- THE 2014 FBC TOOK EFFECT ON JUNE 30TH, 2015. PERMIT | | | APPLICATION WAS SUBMITTED ON JUNE 30TH. BUILDING REVIEW | | | WILL BE DONE BASED ON THE NEW CODE. PLEASE UPDATE ALL | | | PLANS AND NOTES AS REQUIRED. | | | | | | 3- FOR YOUR INFORMATION THIS PROPERTY IS LOCATED IN | | | FLOOD ZONE A5. ELEVATIONS CERTIFICATES WILL BE REQUIRED | | | DURING CONSTRUCTION. | | | | | | 4- ARCHITECTURAL PLANS TITLE BLOCK IS MISSING ALL THE | | | INFORMATION OF THE ARCHITECT WHO IS SIGNING AND SEALING | | | THE PLANS AS REQUIRED BY FAC 61G1-16.004. | | | | | | 5- PROVIDE SOIL TEST REPORT (2 COPIES). SEC. R401.4 OF | | | 2010 FBC-RESIDENTIAL-5TH EDITION (2014). | | | | | | 6-SHEET A-1: REVISE THE RETENTION NOTE ON SOIL/DRAINAGE | | | NOTES. SEE SEC. R318.5 AND SEC. R401.3. | | | | | | 7- SHEET A5: | | | A) A LANDING IS REQUIRED FROM THE EXERCISE ROOM TO THE | | | COVERED LANAI AS REQUIRED BY SEC. R311.3 | | | | | | B) PROVIDE SPECIFICATIONS FOR GARAGE DOORS LEADING TO | | | THE CLUB ROOM AND TO THE FOYER SHOWING COMPLIANCE WITH | | | SEC. R302.5.1. ALSO, ALL THE DOORS NEED TO BE EQUIPPED | | | WITH A SELF-CLOSING DEVICE. PROVIDE SPECIFICATIONS ON | | | PLANS. | | | | | | C) PROPERTY IS LOCATED IN FLOOD ZONE A5. PROVIDE SPECS | | | FOR THE ELEVATOR PIT AND PIT FOR HYDRAULIC LIFT SHOWING | | | COMPLIANCE WITH SEC. R322. | | | | | | D) DOOR 09 DOESN'T MATCH DOOR SCHEDULE. REVISE AS | | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | E) AREA CALCULATIONS ARE INCORRECT. THE ADDITION OF THE | | | AREAS IS INCORRECT. REVISE AS REQUIRED. SEC. 107.2..1 | | | CITY AMENDMENTS. | | | | | | 8- PROVIDE COMPLIANCE WITH THE ACCESSIBILITY SEC. R320. | | | | | | 9- SHEET A6: SPECIFY OVERFLOW DRAINS OR SCUPPERS AS | | | REQUIRED BY SEC. R903.4.1. | | | | | | 10- SHEET A7: SPECIFY OVERFLOW DRAINS OR SCUPPERS AS | | | REQUIRED BY SEC. R903.4.1. | | | | | | 11- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING | | | COMPLIANCE WITH THE ROOF VENTILATION SEC. R806. | | | NOTE: COORDINATE WITH-THE ENERGY CALCULATIONS. | | | | | | 12- SHEET A10: STAIR RAILING DETAIL DOESN'T MATCH | | | PLANS. REVISE AS REQUIRED. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | NOTE: PROVIDE COMPLETE STAIRWAY AND RAILING SYSTEM | | | SPECIFICATIONS, REVIEWED BY THE DESIGNER OF RECORD. | | | THIS MAY BE SUBMITTED LATER AS A PROVISO PRIOR TO | | | INSTALLATION. | | | | | | 13- PROVIDE ICC EVALUATION REPORT FOR THE SPRAY | | | INSULATION SPECIFIED ON PLANS. SEC. R316. | | | | | | 14- SHEET A14: REVISE WINDOW DETAILS THAT SHOW BEVELED | | | BUCK. NEED TO SHOW BUCKS THAT PROVIDE FULL SUPPORT TO | | | THE WINDOW FRAME AS REQUIRED BY SEC. R612.7.2.1. | | | | | | 15- REVISE ENERGY CALCULATIONS SUBMITTED: | | | A) NEED TO USE CURRENT FORM FBC- ENERGY CONSERVATION, | | | 5TH EDITION (2014). | | | | | | B) JURISDICTION NUMBER DOESN'T CORRESPOND TO CITY OF | | | WEST PALM BEACH AND THE PERMIT OFFICE IS NOT PALM | | | BEACH. ALSO, PROVIDE THE OWNER AND BUILDER INFORMATION. | | | SEC. R101.5.1.1.2 OF FBC- ENERGY CONSERVATION, 5TH | | | EDITION (2014). | | | | | | C) CONDITIONED FLOOR AREA DOESN'T MATCH PLANS. SEC. | | | R101.5.1.1.2 OF FBC- ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | | | | D) PROVIDE THE NAME OF THE INDIVIDUAL COMPLETING THE | | | REPORT AS REQUIRED BY SEC. R405.4.2 OF FBC- ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | E) ROOF INFORMATION ON PAGE 3 OF 7: REVISE ROOF TYPE | | | AND MATERIALS TO MATCH PLANS. PLANS SHOW MODIFIED | | | BITUMEN AND METAL ROOF. SEC. R101.5.1.1.2 OF FBC- | | | ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | F) CEILING INFORMATION ON PAGE 3 OF 7: R VALUE TO MATCH | | | PLANS AND PAGE 1 OF 7. SEC. R101.5.1.1.2 OF FBC- ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | G) WINDOWS ON PAGE 4 OF 7: REVISE OVERHANG DEPTH AND | | | SEPARATION TO MATCH PLANS. SEC. R101.5.1.1.2 OF FBC- | | | ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | H ) PROVIDE WINDOWS AND DOORS MANUFACTURER'S SPECS | | | SHOWING COMPLIANCE WITH THE U-FACTOR AND SHGC FACTOR | | | SPECIFIED ON ITEM #7 AS REQUIRED BY SEC. R405.4.3 OF | | | FBC- ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | 16- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) CUSTOM ENTRY DOOR AS SHOWN ON PLANS. PROVIDE | | | COMPLETE ENGINEERING PACKAGE FOR BUILDING OFFICIAL | | | APPROVAL. CONTACT BROWN AT [email protected]. | | | | | | B) 18'-0" OVERHEAD GARAGE DOOR THAT MEETS THE DESIGN | | | PRESSURES CALCULATED BY THE ENGINEER OF RECORD. NOA | | | 15-0317.01 SUBMITTED DOESN'T MEET THE DESIGN PRESSURES. | | | | | | C) STOREFRONT SYSTEM WITH WINDOW SIZES AS SHOWN ON | | | PLANS. SEE WINDOWS W02, W04 AND W05. NOA 12-1005.01 | | | SUBMITTED DOESN'T COVER THOSE SIZES. | | | | | | D) SLIDING GLASS DOOR #D10 WITH SIZE AS SHOWN ON PLANS. | | | NOA 12-0130.13 SUBMITTED DOESN'T COVER THIS SIZE. | | | MAXIMUM PANEL SIZE FOR A 10'-0" HIGH DOOR IS 48". | | | | | | E) CASEMENT WINDOW #W12 AS SHOWN ON PLANS. THERE | | | WINDOWS MULLED TOGETHER. | | | | | | F) DOOR #D07 AS SHOWN ON PLANS. SEE SIZE AND DOOR WITH | | | FIXED SIDELITES ASSEMBLY. | | | | | | G) STEEL PANEL WALL SYSTEM AS SHOWN ON PLANS. | | | | | | H) 14" EXHAUST AIR GRILLS AS SHOWN ON PLANS. | | | | | | I) METAL ROOF AS SHOWN ON PLANS. | | | | | | J) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON | | | PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND | | | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF | | | SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN | | | PRESSURES. | | | | | | K) PRECAST LINTELS AS SPECIFIED ON PLANS. | | | | | | L) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS | | | AND DETAILS. PROVIDE FLORIDA PRODUCT APPROVAL COVER | | | PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR LIST | | | THE FLORIDA PRODUCT APPROVAL NUMBER NEXT TO THE | | | SPECIFIED CONNECTOR. | | | | | | 17- DESIGNER OF RECORD TO APPROVE IN WRITING (NOT | | | SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED | | | BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 18- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | | FINISH COVERING OF THE SECOND FLOOR COVERED TERRACE. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 19- NOTE: PRIOR TO FABRICATION AND INSTALLATION PROVIDE | | | COMPLETE ENGINEER PACKAGE FOR THE BAR JOIST AND | | | CONCRETE DECK SYSTEMS, STAIRWAY , HANDRAILS AND | | | GUARDRAILS APPROVED BY THE DESIGNER OF RECORD. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING. | | | SUBMIT OLD COPIES FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | 2015-07-24 14:31:31 | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2015-12-10 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-10 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-10 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2015-12-10 09:07:53 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | PHIL PETTY | | | 561-805-6742 | | | [email protected] | | | | | | | | | 240.4 PROTECTION OF CONDUCTORS. CONDUCTORS, OTHER THAN | | | FLEXIBLE CORDS, FLEXIBLE CABLES, AND FIXTURE WIRES, | | | SHALL BE | | | PROTECTED AGAINST OVERCURRENT IN ACCORDANCE WITH THEIR | | | AMPACITIES | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2015-12-02 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-02 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-02 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2015-12-02 16:26:03 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | PHIL PETTY | | | 561-805-6742 | | | [email protected] | | | | | | | | | | | | | | | 1- WRONG GEC SIZE FOR SERVICE PLEASE TAKE A LOOK AT | | | TABLE 250.66 NEC | | | 2- WRONG OVERCURRENT DEVICE FOR DISCONNECT B AND C | | | 240.4 PROTECTION OF CONDUCTORS. CONDUCTORS, OTHER THAN | | | FLEXIBLE CORDS, FLEXIBLE CABLES, AND FIXTURE WIRES, | | | SHALL BE | | | PROTECTED AGAINST OVERCURRENT IN ACCORDANCE WITH THEIR | | | AMPACITIES | | | SPECIFIED IN 310.15 | | | 3-AC DISCONNECTS NOT DRAWN READILY ACCESIBLE | | | 440.14 LOCATION. DISCONNECTING MEANS SHALL BE LOCATED | | | WITHIN SIGHT FROM AND READILY ACCESSIBLE FROM THE | | | AIRCONDITIONING | | | OR REFRIGERATING EQUIPMENT. | | | 4-FIRST FLOOR ELECTRICAL PLAN SHOWS SWITCH INSIDE A | | | DOOR OPENNIG ( TYPO) | | | 5-POOL EQUIPMENT DOESN'T SHOW GFCI PROTECTION | | | 440.14 LOCATION. DISCONNECTING MEANS SHALL BE LOCATED | | | WITHIN SIGHT FROM AND READILY ACCESSIBLE FROM THE | | | AIRCONDITIONING | | | OR REFRIGERATING EQUIPMENT. | | | 6-ISLAND RECEPTACLES DOESN'T SHOW GFCI PROTECTION ? | | | 7-RECESSD LIGHTS ARE NOT SHOWN TO BE IC RATED ? | | | 8-PLEASE PROVIDE MOUNTING DETAIL FOR FLOURESECENT | | | FIXTURES ON FIRST FLOOR GARAGE. | | | 9-PLEASE PROVIDE MANUFACTURE SPECS FOR CAR LIFTS AND | | | ELEVATOR EQUIPMENT. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-11-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-11-15 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-11-15 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2015-11-15 12:09:15 | REVIEW BY PPETTY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2015-08-26 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2015-08-26 09:37:38 | 250.64 CHECK GEC SIZE | | | MAIN TAPS AT METER NOT TO FPL SERVICE STANDARDS | | | PHIL 561-644-7305 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2015-11-12 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-11-12 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-11-12 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2015-11-12 13:56:36 | CALCULATIONS ADDED TO C-1, DATED 10/2/2015 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2015-09-01 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-09-01 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-09-01 |
Time |
11:49 |
Sent To |
M |
|
| Notes |
| 2015-09-01 14:37:34 | PLEASE SHOW LOCATIONS AND SIZES OF PROPOSED POTABLE | | | WATER AND SANITARY SEWER SERVICES. | | | | | | EXISTING STORM SYSTEM ALONG THE PROPERTY'S SOUTHERN | | | PROPERTY LINE WILL BE REMOVED AND REPLACED BY THE | | | CITY'S RUTLAND BLVD IMPROVEMENTS PROJECT. PLEASE | | | CONTACT TRACY WARD, PE TO DISCUSS THE FEASIBILITY OF | | | DIRECTLY OR INDIRECTLY CONNECTING TO THE NEW SYSTEM. | | | (561) 494-1120. | | | | | | THE SUBMITTED SURVEY HAS INCORRECTLY LABELED THE | | | RUTLAND BLVD CUL-DE-SAC AS FLAGLER AVENUE. | | | | | | PLEASE SUBMIT SIGNED AND SEALED CALCULATIONS FOR THE | | | PROPOSED EXFITLRATION TRENCH. | | | | | | PLEASE SHOW A DETAIL OF THE PROPOSED RETAINING WALL AND | | | THE FOOTER PROXIMITY TO THE PROPERTY LINE. | | | | | | THE PROPOSED CONSTRUCTION FALLS WITHIN ZONE A5 OF THE | | | LAKE WORTH LAGOON, WITH A BASE FLOOD ELEVATION OF 7.0 | | | NGVD. PLEASE VERIFY RAISING THE GROUND ELEVATION ABOVE | | | THE FLOOD ELEVATION WILL ALLOW THE EXISTING SHEETFLOW | | | TO CONTINUE TO REACH THE LAGOON. TYPICALLY, BROAD FLAT | | | AREAS A LEFT FOR THIS FLOW PATH RATHER THAN NARROW | | | V-SHAPED AREAS. | | | | | | KELLY CRANFORD, P.E. | | | LAND DEVELOPMENT ENGINEER | | | PUBLIC WORKS DEPARTMENT | | | CITY OF WEST PALM BEACH | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | | | | | | 2015-08-31 11:57:22 | SEE CIVIL DRAWINGS SUBMITTED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-15 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-10 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-12-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-04 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-20 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-11-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-11-15 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-10-14 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-09-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-09-11 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-06-30 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-15 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-15 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2015-12-15 08:51:16 | NO FEES. MU-2015-028620. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-11-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-03 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-03 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2015-11-03 15:41:18 | 1-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY | | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | | CODE. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-08-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-28 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-28 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2015-08-28 08:36:29 | 1-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY | | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | | CODE. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-12-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-03 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-03 |
Time |
07:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-10-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-10-28 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-10-28 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2015-10-28 12:18:57 | 2ND REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15061466 | | | 10/28/15 | | | | | | SOME OF THE COMMENTS FROM THE 1ST REVIEW HAVE NOT BEEN | | | COMPLETELY ADDRESSED ON THE PLANS. I AM REPRINTING | | | THOSE COMMENTS IN THIS REVIEW. | | | PLEASE PROVIDE: | | | 1-D) AIR DISTRIBUTION SCHEDULE INDICATING MAKES, | | | MODELS, AND DIMENSIONS OF DIFFUSERS AND GRILLS. | | | 1-E) AC DUCT CONNECTION, SUPPORT AND HANGING DETAILS | | | 1-I) VERIFICATION OF CONDENSER INSTALLATION AT OR ABOVE | | | THE BASE FLOOD ELEVATION HEIGHT- SEE SECTION R322.1.6 | | | FBC-14 RESIDENTIAL. | | | 5) PROVIDE SIZING CALCULATIONS FOR THE EXHAUST | | | VENTILATION SYSTEMS SHOWN IN THE THE GARAGE, BIKE SHOP, | | | AND STORAGE AREA ON THE 1ST FLOOR. | | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE CARBON | | | MONOXIDE DETECTORS AND INDICATE THEIR EXACT | | | INSTALLATION LOCATIONS ON THE PLAN (SPACINGS, HEIGHT | | | AFF). | | | 7) SUBMIT FL. PRODUCT APPROVALS OR MIAMI-DADE NOA'S FOR | | | THE EXHAUST AND MAKE UP AIR LOUVERS. | | | 8) THE U-FACTORS SHOWN ON THE ENERGY CALCULATIONS FOR | | | THE WINDOWS DO NOT MATCH THE VALUES LISTED ON THE AC | | | CALCULATIONS. | | | 9) THE OVERHEAD DOORS IN THE MAIN GARAGE AND STORAGE 3 | | | ARE INDICATED AS WOOD DOORS ON THE ENERGY CALCS, | | | HOWEVER THE NOA SUBMITTED FROM AMARR SHOWS THEM TO BE | | | STEEL. ALSO NO DATA IS SHOWN ON THE CALCS FOR THE MAN | | | DOOR IN THE GARAGE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-09-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-09-11 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-09-11 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2015-09-11 16:28:34 | 1ST REVIEW: FBC 2014 RESIDENTIAL | | | PERMIT #15061466 | | | 9/11/15 | | | | | | 1) SUBMIT COMPLETE MECHANICAL PLANS, DETAILS, AND | | | SPECIFICATIONS FOR REVIEW INCLUDING: | | | A) AC DUCT LAYOUT PLANS FOR EACH NEW SYSTEM INDICATING | | | THE TYPES AND SIZES OF DUCTS, SUPPLY CFM'S AT EACH | | | DIFFUSER, MEANS OF RETURN AIR INCLUDING DIMENSIONS OF | | | RETURN AIR GRILLS, TRANSFER GRILLS, AND RETURN CFM'S. | | | REFER TO SECTION M1602.2 FOR PROHIBITED RETURN AIR | | | SOURCES. | | | B) AC EQUIPMENT SCHEDULES LISTING THE MAKES AND MODELS | | | OF ALL COMPONENTS, COOLING AND HEATING CAPACITIES, | | | EFFICIENCY RATINGS, ELECTRICAL DATA ETC. | | | C) AHRI CERTIFICATES FOR EACH NEW SYSTEM. | | | D) AIR DISTRIBUTION SCHEDULE INDICATING MAKES, MODELS, | | | AND DIMENSIONS OF DIFFUSERS AND GRILLS. | | | E) AC DUCT CONNECTION, SUPPORT AND HANGING DETAILS | | | F) DIMENSIONED PLAN AND SECTION VIEWS OF THE AIR | | | HANDLER CLOSET INDICATING COMPLIANCE WITH SECTION | | | M1305.1.1 FBC-14 RESIDENTIAL, AND SECTION C403.2.7.2 | | | FBC-14 ENERGY CONSERVATION- SHOW THE MEANS OF RETURN | | | AIR TO EACH UNIT IN THE CLOSET. | | | G) CONDENSATE DISPOSAL PLANS- PRIMARY AND SECONDARY FOR | | | EACH NEW AIR HANDLER- SEE SECTION M1411.3 RESIDENTIAL. | | | H) WIND LOAD TIE DOWN ENGINEERING FOR MOUNTING THE AC | | | CONDENSERS TO THE NEW PADS- SEE SECTIONS M1305.1.4.1 & | | | M1307.2 FBC-14 RESIDENTIAL | | | I) VERIFICATION OF CONDENSER INSTALLATION AT OR ABOVE | | | THE BASE FLOOD ELEVATION HEIGHT- SEE SECTION R322.1.6 | | | FBC-14 RESIDENTIAL. | | | 2) PROVIDE BATHROOM EXHAUST DETAILS: EXHAUST FAN | | | EQUIPMENT SCHEDULES, EXHAUST DUCT RUNS AND TERMINATION | | | LOCATIONS. | | | 3) PROVIDE DRYER EXHAUST AND MAKEUP AIR PLANS PER | | | SECTION M1502: SHOW THE TYPE AND SIZE OF EXHAUST DUCT, | | | EXHAUST DUCT RUN LENGTH AND TERMINATION LOCATION, AND | | | INDICATE HOW MAKEUP AIR WILL BE SUPPLIED TO EACH DRYER. | | | SUBMIT MANUFACTURER'S SPECS FOR THE APPLIANCES. | | | 4) REFER TO SECTION M1503 AND PROVIDE KITCHEN EXHAUST | | | VENTILATION PLANS. | | | 5) PROVIDE SIZING CALCULATIONS FOR THE EXHAUST | | | VENTILATION SYSTEMS SHOWN IN THE THE GARAGE, BIKE SHOP, | | | AND STORAGE AREA ON THE1ST FLOOR. | | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE CARBON | | | MONOXIDE DETECTORS AND INDICATE THEIR EXACT | | | INSTALLATION LOCATIONS ON THE PLAN (SPACINGS, HEIGHT | | | AFF). | | | 7) SUBMIT MANUFACTURER'S SPECIFICATIONS AND FL. PRODUCT | | | APPROVALS FOR THE EXHAUST AND MAKE UP AIR FANS AND | | | LOUVERS. PROVIDE FAN SCHEDULES ON THE PLANS INDICATING | | | THEIR CFM CAPACITIES, ELECTRICAL DATA ETC. | | | PLEASE NOTE ADDITIONAL COMMENTS MAY FOLLOW SUBMITTAL OF | | | REVISED PLANS AND RESPONSES TO ALL BUILDING DEPARTMENT | | | COMMENTS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2016-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-03-23 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-03-23 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2016-03-23 11:51:33 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. THE LATITUDE / LONGITUDE IS NOT THE SAME AS ON THE | | | EC PROVIDED AT TIME OF PLAN REVIEW. IT APPEARS TO BE | | | THE COORDINATES FOR ANOTHER LOCATION (1902 NOTRE DAME | | | DR, LAKE WORTH), PLEASE REVISE OR EXPLAIN. PER EC | | | INSTRUCTIONS, THE LAT/LONG IS TO BE ACCURATE WITHIN | | | 66'. | | | | | | 2. BUILDING TYPE IS 1A, WHICH IS SLAB ON GRADE, BUT | | | LINE A8 A SHOWS 3913.5 SF IN CRAWLSPACE, PLEASE REVISE | | | OR EXPLAIN. THIS IS ALSO NOT CONSISTENT WITH THE | | | "CONSTRUCTION DRAWINGS" ELEVATION CERTIFICATE OR THE | | | PERMIT DOCUMENTS. | | | | | | 3. THE LEGAL OWNER OF RECORD IS SOPHIE SHARP, PLEASE | | | REVISE. | | | | | | 4. AN EXPIRED ELEVATION CERTIFICATE FORM WAS USED. THE | | | NEW ELEVATION CERTIFICATE WHICH EXPIRES NOV 30, 2018 IS | | | TO BE USED. IT CAN BE FOUND HERE: | | | | | | HTTP://NFIPISERVICE.COM/STAKEHOLDER/W_16002/W-16002.HTM | | | L | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
P |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-31 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-31 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2015-12-03 18:28:24 | ***ELEVATION CERTIFICATE REQUIRED*** | | | | | | | | | 12/3/15 CALLED MR. GRUBER, CIVIL ENGINEER FOR THE | | | PROJECT, TO DISCUSS THE PROPOSED NFIP MAP, ADVISED TO | | | INVESTIGATE FUTURE BFE PRIOR TO COMMENCEMENT. | | | | | | PROPOSED CONSTRUCTION COMPLIES WITH CURRENT | | | REQUIREMENTS. FINAL FUTURE NFIP MAP IS NOT AVAILABLE AT | | | THIS TIME. | | | | | | | | | | | | | | 2015-08-31 13:33:40 | PLEASE NOTIFY SAMANTHA HILL WHEN PERMIT IS ISSUED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-12-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-12-01 |
Time |
06:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-30 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-10-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-10-21 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-10-21 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-07-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-07-27 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-07-23 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2015-07-27 15:43:06 | | | | 1. GARAGE SHOWS AUTOMOBILE LIFT AND ELECTRICAL BOXES | | | NOTED AS "CAR EQUIPMENT" AN AIR COMPRESSOR, CARBON | | | MONOXIDE SENSOR , ETC. THIS HAS ALL THE APPEARANCE OF A | | | VEHICLE REPAIR FACILITY. WHICH FALLS UNDER AN S-1 | | | OCCUPANCY AND THE 2014 BC PLUMBING CODE. | | | | | | 2A. WHERE ARE THE FLOOR DRAINS TERMINATING | | | 2B.AN OIL SEPARATOR IS REQUIRED PER 2014 FBC P 1003.4 | | | AND SHALL COMPLY WITH FBC P SEC. 1003.4.1 THRU | | | 1003.4.2.2 FLOOR DRAINS MUST DISCHARGE THRU OIL | | | SEPARATOR. | | | | | | 3.DOWNSPOUTS SHALL BE SIZED IN ACCORDANCE WITH 2014 FBC | | | P TABLE 1106.2[2] SHEET A-9 INDICATE SIZE OF DOWNSPOUTS | | | SQ FT. BEING DRAINED BY EACH DOWNSPOUT BASED ON 5IN. | | | RAINFALL RATIO 1/2 THE AREA OF ANY VERTICAL THAT | | | CONNECTS TO ROOF SHALL BE CALCULATED IN TH SQ. FT. | | | CALCULATIONS. | | | | | | 4.PLEASE INDICATE ON THE PLAN IF THE ELEVATOR IS | | | TRACTION TYPE OR HYDRAULIC IF HYDRAULIC PIT MUST DRAIN | | | THRU OIL SEPARATOR FBC 10004.3. | | | | | | 5.SUBMIT POTABLE WATER RISER. PER WPB AMENDMENTS TO FBC | | | 2010 107.3.5.2 | | | | | | 6. INDICATE ON THE PLAN IF ANY COMPRESSED AIR PIPING | | | WILL BE INSTALLED, IF SO SUBMIT A RISER DIAGRAM FOR AIR | | | PIPING SHOW SUPPORT,SIZINGS TYPE OF PIPE USED ,VALVES | | | AND OUTLETS ETC. | | | | | | 7.SHEET A-10 BLDG. SEC A-A SHOWS HYDRAULIC LIFT PIT | | | WITH TWO DRAIN PIPES WHAT IS THE USE OF THESE LINES | | | ,ARE THEY PERFORATED PLEASE CLARIFY. | | | | | | | | | | | | | | | | | | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-15 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-15 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2015-12-15 08:59:21 | PROVISO: | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) METAL ROOF AS SHOWN ON PLANS. | | | | | | B) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON | | | PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND | | | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF | | | SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN | | | PRESSURES. | | | | | | C) PROVIDE COMPLETE DETAILS, SPECIFICATIONS AND PRODUCT | | | APPROVAL FOR THE FINISH COVERING UNDERLAYMENT OF THE | | | SECOND FLOOR COVERED TERRACE. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | 2- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | NOTE: PLEASE PLACE THE REVIEW STAMP ON THE FRONT OF THE | | | PRODUCT APPROVAL COVER PAGE NOT ON THE BACK (OR ON ANY | | | OTHER FRONT PAGE WHERE THERE IS ENOUGH ROOM FOR THE | | | STAMP). SCANNING DOCUMENTS FOR RECORD KEEPING IS NOT | | | ADEQUATE WHEN STAMPS ARE ON THE BACK OF THE PAGE. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2015-12-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-04 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-04 |
Time |
18:20 |
Sent To |
|
|
| Notes |
| 2015-12-04 18:24:52 | | | | NOTE: | | | COMMENTS BELOW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS TO ISSUE PERMIT AND REVISED PLANS ADDRESSING THE | | | COMMENTS WILL BE SUBMITTED LATER. FEES MAY APPLY. NEED | | | CONTRACTOR'S APPROVAL TO GO AHEAD WITH THE PROVISO | | | OPTION. BUT, BEFORE ISSUING THE PERMIT, ALL THE | | | STRUCTURAL DRAWINGS NEED TO BE RE-SUBMITTED WITHOUT THE | | | "NOT FOR CONSTRUCTION" NOTE. | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) METAL ROOF AS SHOWN ON PLANS. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | B) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON | | | PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND | | | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF | | | SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN | | | PRESSURES. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | C) PROVIDE COMPLETE DETAILS, SPECIFICATIONS AND PRODUCT | | | APPROVAL FOR THE FINISH COVERING UNDERLAYMENT OF THE | | | SECOND FLOOR COVERED TERRACE. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | RESPONSE: TO BE SUBMITTED LATER. OK. | | | | | | 2- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | NOTE: PLEASE PLACE THE REVIEW STAMP ON THE FRONT OF THE | | | PRODUCT APPROVAL COVER PAGE NOT ON THE BACK (OR ON ANY | | | OTHER FRONT PAGE WHERE THERE IS ENOUGH ROOM FOR THE | | | STAMP). SCANNING DOCUMENTS FOR RECORD KEEPING IS NOT | | | ADEQUATE WHEN STAMPS ARE ON THE BACK OF THE PAGE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-31 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-31 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2015-08-31 15:21:11 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) METAL ROOF AS SHOWN ON PLANS. | | | | | | B) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON | | | PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND | | | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF | | | SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN | | | PRESSURES. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-12-03 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-12-03 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-12-03 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2015-10-22 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-10-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2015-10-22 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-10-22 11:09:05 | 2ND CHECKLIST 10/22/15 | | | | | | 1. THE LIFT WILL NOT BE PERMITTED IN THE SF7 ZONING | | | DISTRICT AS PER ANGELLA VANN, ZONING ADMINISTRATOR. | | | | | | 2. THE MAX HEIGHT IN SF7 ZONING IS 30' FEET, YOU HAVE | | | LEVELS SOME ARE 32' FEET AND 34' FEET, YOU MUST MEASURE | | | FROM GRADE TO THE ROOF MEAN. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-08-10 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-08-10 |
Time |
14:40 |
Rev Time |
|
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-08-10 14:44:52 | 8/10/15 ZONING FAILED | | | | | | 1. AUTOMOBILE LIFTS ARE NOT ALLOWED IN SF7 ZONING, THIS | | | IS COMMERICAL EQUIPMENT. | | | 2. THE MAXIMUM HEIGHT IN SF7 IS 30' FEET, YOU HAVE | | | DIFFERENGT LEVELS, SOME ARE 32' AND 34' FEET, MEASURING | | | THE ROOF MEAN |
|
|