2016-01-25 13:00:14BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- REVISE SIZE OF HEATING/COOLING UNIT FOR NEW BEDROOM:
 SIZE OF HEATING AND COOLING WALL UNIT SHOWN ON PLANS IS
 OVERSIZED FOR THE NEW BEDROOM. 8,000 BTU UNIT IS
 OVERSIZED FOR A ROOM WITH LESS THAN 100S.F . PROVIDE
 EQUIPMENT SIZING CALCULATIONS. SEC. C403.2.1 OF
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). EQUIPMENT
 CAN NOT EXCEED THE CALCULATED LOADS. SEC. C403.2.2 OF
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2016-01-05 Cont ID  
Sent By lmarchan Date 2016-01-21 Time 08:02 Rev Time 0.00
Received By jgomez Date 2016-01-05 Time 16:57 Sent To  
Notes
2016-01-05 17:04:18RESIDENTIAL (R2) ALTERATION, 4TH BUILDING REVIEW
 CHECKLIST.
 CODE: FBC-5TH EDITION (2014).
  
 1- PLANS WERE REVISED AND NEW CASEMENT WINDOW WAS
 SPECIFIED ON PLANS FOR THE NEW BEDROOM. THE CASEMENT
 WINDOW COMPLIES WITH EGRESS. NEED TO PROVIDE PRODUCT
 APPROVAL (2 COPIES) FOR THE CASEMENT WINDOW AS REQUIRED
 BY FAC 61G20-3.002(3).
 RESPONSE: PRODUCT APPROVAL NOA NO 15-0728.05 SUBMITTED
 IS FOR "HORIZONTAL ROLLING WINDOW". ENGINEER DRAWING
 A-2 SPECIFIES 37.5" X 50.625" CASEMENT WINDOW. THE
 CASEMENT WINDOW SIZE SPECIFIED ON PLANS COMPLIES WITH
 THE EGRESS REQUIREMENTS. THE HORIZONTAL ROLLING WINDOW
 DOESN'T COMPLY. ENGINEER OF RECORD APPROVED NOA
 SUBMITTED AND IT DOESN'T COMPLY.
  
 2- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 NEW TENANT SEPARATION WALL THAT MATCHES PROPOSED FLOOR
 PLAN. SHOW COMPLIANCE WITH SEC. 420.2 FBC. 5TH EDITION.
 RESPONSE:
 A) TENANT SEPARATION WALL SUBMITTED IS "BEARING 1 HOUR
 FIRE RATED WALL U.L. DESIGN NO U305". CLARIFY WHY THERE
 IS ONLY ONE 2X4 TOP PLATE?. ALSO, WOOD FRAMED WALL
 SUPPORTING CONCRETE SLAB NEED TO PROVIDE COMPLIANCE
 WITH SEC. 2304.12 OF FBC FOR LONG TERM LOADING.
 ENGINEER OF RECORD TO PROVIDE COMPLIANCE.
  
 B) PROVIDE UL COPY OF COMPLETE SPECIFICATIONS FOR THE
 U.L. NO U305 ASSEMBLY SHOWING 1" GAP BETWEEN STUD AND
 TOP RUNNER AS SHOWN ON WALL DETAIL SUBMITTED. . SHOW
 GYPSUM BOARD FASTENING. SEC. 107.2.1 CITY AMENDMENTS.
  
 3- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 HOW THE EXTERIOR WALL DOOR OPENING IS GOING TO BE
 CLOSED. SEC. 1609 FBC.
 RESPONSE: DETAIL C/2 SUBMITTED IS NOT CLEAR. ENGINEER
 NEEDS TO BE SPECIFIC WITH WHAT KIND OF 12" METAL STRAP
 IS GOING TO BE USED. "12" METAL STRAP IS VERY GENERIC.
 THERE ARE MANY TYPES AND MANUFACTURERS FOR 12" METAL
 STRAPS. ALSO, PROVIDE COMPLETE DETAIL SHOWING HOW IS
 THE 12" STRAP ATTACHED TO THE TOP AND BOTTOM PLATES.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 NOTE: INSPECTIONS WILL BE REQUIRED TO VERIFY EXISTING
 TENANT SEPARATION WALLS, CEILINGS AND FLOORS. AND,
 EXTERIOR WALLS.
  
 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE TEMPERATURE CONTROL FOR THE NEW
 BEDROOM AS REQUIRED BY SEC. 1204 FBC.
 RESPONSE: SIZE OF HEATING AND COOLING WALL UNIT SHOWN
 ON PLANS IS OVERSIZED FOR THE NEW BEDROOM. 8,000 BTU
 UNIT IS OVERSIZED FOR A ROOM WITH LESS THAN 100S.F .
 PROVIDE EQUIPMENT SIZING CALCULATIONS. SEC. C403.2.1 OF
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). EQUIPMENT
 CAN NOT EXCEED THE CALCULATED LOADS. SEC. C403.2.2 OF
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 NOTE:
 ENGINEER OF RECORD TO PAY FOUR TIMES THE PLAN REVIEW
 FEE AS REQUIRED BY FLORIDA STATUTE 553.80(2)(B) FOR
 PLANS REJECTED MORE THAN 3 TIMES.
 PLANS WILL BE SUBMITTED TO THE BOARD OF ENGINEERS FOR
 REVIEW.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-12-16 Cont ID  
Sent By lmarchan Date 2015-12-17 Time 13:32 Rev Time 0.00
Received By jgomez Date 2015-12-16 Time 11:07 Sent To E
Notes
2015-12-16 11:07:58RESIDENTIAL (R2) ALTERATION, THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: FBC-5TH EDITION (2014).
  
 NOTE:
 ENGINEER OF RECORD WILL BE CHARGED FOUR TIMES THE PLAN
 REVIEW FEE AS REQUIRED BY FLORIDA STATUTE 553.80(2)(B)
 IF PLANS ARE REJECTED ONE MORE TIME.
  
 1- PLANS WERE REVISED AND NEW CASEMENT WINDOW WAS
 SPECIFIED ON PLANS FOR THE NEW BEDROOM. THE WINDOW NOW
 COMPLIES WITH EGRESS. NOW NEED TO PROVIDE PRODUCT
 APPROVAL (2 COPIES) FOR THE CASEMENT WINDOW AS REQUIRED
 BY FAC 61G20-3.002(3).
  
 2- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 NEW TENANT SEPARATION WALL THAT MATCHES PROPOSED FLOOR
 PLAN. SHOW COMPLIANCE WITH SEC. 420.2 FBC. 5TH EDITION.
 RESPONSE: (A) THE NEW TENANT SEPARATION WALL ASSEMBLY
 U474 SUBMITTED IS FOR AN EXTERIOR WALL. NEED TENANT
 SEPARATION WALL ASSEMBLY FOR AN INTERIOR APPLICATION AS
 SHOWN ON PLANS. SEC. 107.2.1 CITY AMENDMENTS.
  
 (B) THE NEW TENANT SEPARATION WALL DETAIL SUBMITTED
 DOESN'T MATCH FLOOR PLAN. FLOOR PLAN SHOWS TWO WALLS.
 CLARIFY/REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 3- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 HOW THE EXTERIOR WALL DOOR OPENING IS GOING TO BE
 CLOSED WITH "DRYWALL" TO SHOW COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. 1609 FBC.
 RESPONSE: BLOCK-UP DETAIL IS INCOMPLETE. MISSING A LOT
 OF INFORMATION. PROVIDE A COMPLETE WALL ASSEMBLY THAT
 MATCHES FLOOR PLAN. FLOOR PLAN SHOWS TWO WALLS.
 CLARIFY/REVISE AS REQUIRED TO MATCH. CLEARLY SPECIFY
 ALL CONNECTORS. METAL STRAPS IS NOT ENOUGH INFORMATION.
 ALSO, THIS IS AN EXTERIOR WALL. INFORMATION SUBMITTED
 DON'T COMPLY FOR AN EXTERIOR WALL ASSEMBLY. CLEARLY
 PROVIDE SPECIFICATIONS FOR THE INTERIOR SIDE AND
 EXTERIOR SIDE. SEC. 107.2.1 CITY AMENDMENTS.
  
 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE TEMPERATURE CONTROL FOR THE NEW
 BEDROOM AS REQUIRED BY SEC. 1204 FBC.
 RESPONSE: FLOOR PLAN SHOWS NEW WALL AC. THIS DOESN'T
 SATISFY THE HEATING REQUIREMENT. PLANS CALL ONLY FOR
 AC. ALSO, THERE IS NO DEDICATED OUTLET SHOWN FOR THE
 HEATING UNIT.. NOTE: HEATING IS MANDATORY, COOLING IS
 NOT. THE UNIT MAY BE AN A/C UNIT WITH HEAT.BUT, PLANS
 NEED TO SPECIFY IT AND CORRESPONDENT DEDICATED OUTLET
 IS REQUIRED. PROVIDE MANUFACTURER'S SPECS FOR SELECTED
 A/C WITH HEAT AND REVISE PLANS AS REQUIRED.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-10-05 Cont ID  
Sent By jgomez Date 2015-10-05 Time 13:46 Rev Time 0.00
Received By jgomez Date 2015-10-05 Time 13:46 Sent To P
Notes
2015-10-05 13:53:22RESIDENTIAL (R2) ALTERATION, BUILDING REVIEW COMMENTS.
 CODE: FBC-5TH EDITION (2014).
  
 NOTE: ON 10/6/15 TALKED TO ART LANGE (BLDG. INSPECTOR
 WHO RE-TAGGED THE JOB). THERE IS A LOT OF WORK DONE
 WITHOUT PERMITS ON SEVERAL UNITS. PLANS NEED TO SHOW
 ALL THE SCOPE OF WORK ON ALL UNITS.
  
 1- THERE ARE SEVERAL BUILDINGS IN THIS PARCEL. PROVIDE
 A KEY PLAN SHOWING SPECIFIC BUILDING WHERE WORK IS
 TAKEN PLACE. SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 AREA OF WORK SHOWN ON DRAWING 1 OF 2 SUBMITTED DOESN'T
 MATCH FLOOR PLAN SHOWN ON DRAWING 2 OF 2. THE FLOOR
 PLAN SHOWN ON DRAWING 2 OF 2 LOOKS LIKE AN END UNIT,
 WHILE AREA OF WORK SHOWN ON DRAWING 1 OF 2 IS SOMEWHERE
 IN THE MIDDLE OF THE BUILDING. REVISE AS REQUIRED TO
 MATCH.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR , MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. . REVISE VALUATION AND PROVIDE COPY OF
 SIGNED CONTRACT THAT SHOWS ALL THE SCOPE OF WORK.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 3- NEW BEDROOM WAS CREATED. SPECIFY COMPLIANCE WITH THE
 EMERGENCY EGRESS REQUIREMENTS OF SEC. 1029 FBC.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 NEW TENANT SEPARATION WALL THAT MATCHES PROPOSED FLOOR
 PLAN. SHOW COMPLIANCE WITH SEC. 420.2 FBC. 5TH EDITION.
 NOTE: VERIFY THAT EXISTING TENANT SEPARATION WALL IS
 CONCRETE BLOCK WALL. MOST LIKELY IS NOT.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 5- PROVIDE COMPLETE DETAILS AN SPECIFICATIONS FOR THE
 NEW DRYWALL PARTITION THAT MATCHES PROPOSED FLOOR PLAN
 AT THE PERIMETER OF THE DWELLING UNIT AND BETWEEN
 EXISTING BEDROOM AND EXISTING LIVING/DINING AREA. SEC.
 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 6- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 HOW THE EXTERIOR WALL DOOR OPENING IS GOING TO BE
 CLOSED WITH "DRYWALL" TO SHOW COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. 1609 FBC.
  
 RESPONSE:
 BLOCK-UP DETAIL IS INCOMPLETE. MISSING A LOT OF
 INFORMATION. PROVIDE A COMPLETE WALL ASSEMBLY. ALSO,
 LETTERING IS TOO SMALL AND IS NOT LEGIBLE. CLEARLY
 SPECIFY THE TOP AND BOTTOM WOOD STUD CONNECTORS.
  
 7- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE TEMPERATURE CONTROL FOR THE NEW
 BEDROOM AS REQUIRED BY SEC. 1204 FBC.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-08-27 Cont ID  
Sent By jgomez Date 2015-08-26 Time 13:06 Rev Time 0.00
Received By jgomez Date 2015-08-26 Time 12:40 Sent To  
Notes
2015-08-26 13:08:30RESIDENTIAL (R2) ALTERATION, BUILDING REVIEW COMMENTS.
 CODE: FBC-5TH EDITION (2014).
  
 1- THE 2014 FBC TOOK EFFECT ON JUNE 30TH, 2015. PERMIT
 APPLICATION WAS SUBMITTED ON JUNE 30TH, THEREFORE THE
 CODE IN EFFECT IS THE 2014 FBC. ENGINEER TO REVISE
 PLANS AS REQUIRED.
  
 2- THERE ARE SEVERAL BUILDINGS IN THIS PARCEL. PROVIDE
 A KEY PLAN SHOWING SPECIFIC BUILDING WHERE WORK IS
 TAKEN PLACE. SEC. 107.2.1 CITY AMENDMENTS.
  
 3- THIS IS AN APARTMENT BUILDING WITH MORE THAN 2
 UNITS. THIS IS NOT OCCUPANCY GROUP R3. SEE SEC. 310.3
 FBC AND REVISE AS REQUIRED.
  
 4- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR , MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. . REVISE VALUATION AND PROVIDE COPY OF
 SIGNED CONTRACT THAT SHOWS ALL THE SCOPE OF WORK.
  
 5- NEED NOC. SEC. 713 F.S.
  
 6- NEW BEDROOM WAS CREATED. SPECIFY COMPLIANCE WITH THE
 EMERGENCY EGRESS REQUIREMENTS OF SEC. 1029 FBC.
  
 7- WALL TYPES. ACCORDING TO CITY RECORDS, THE EXTERIOR
 WALL OF THIS BUILDING IS NOT WOOD FRAME. REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 NEW TENANT SEPARATION WALL THAT MATCHES PROPOSED FLOOR
 PLAN. SHOW COMPLIANCE WITH SEC. 420.2 FBC.
  
 9- PROVIDE COMPLETE DETAILS AN SPECIFICATIONS FOR THE
 NEW DRYWALL PARTITION THAT MATCHES PROPOSED FLOOR PLAN
 AT THE PERIMETER OF THE DWELLING UNIT AND BETWEEN
 EXISTING BEDROOM AND EXISTING LIVING/DINING AREA. SEC.
 107.2.1 CITY AMENDMENTS.
  
 10- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 HOW THE EXTERIOR WALL DOOR OPENING IS GOING TO BE
 CLOSED WITH "DRYWALL" TO SHOW COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. 1609 FBC.
  
 11- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE TEMPERATURE CONTROL FOR THE NEW
 BEDROOM AS REQUIRED BY SEC. 1204 FBC.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2016-01-28 Cont ID  
Sent By mvaldes Date 2016-01-28 Time 14:55 Rev Time 0.00
Received By mvaldes Date 2016-01-28 Time 14:55 Sent To  
Notes
2016-01-25 16:31:58NEW DRAWINGS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2016-01-20 Cont ID  
Sent By mvaldes Date 2016-01-20 Time 16:00 Rev Time 0.00
Received By mvaldes Date 2016-01-20 Time 16:00 Sent To  
Notes
2016-01-05 17:05:08NEW DRAWINGS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-12-17 Cont ID  
Sent By mvaldes Date 2015-12-17 Time 11:36 Rev Time 0.00
Received By mvaldes Date 2015-12-17 Time 11:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-10-06 Cont ID  
Sent By skennedy Date 2015-10-06 Time 08:53 Rev Time 0.00
Received By skennedy Date 2015-10-06 Time 08:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-09-10 Cont ID  
Sent By skennedy Date 2015-09-10 Time 15:30 Rev Time 0.00
Received By skennedy Date 2015-09-10 Time 15:30 Sent To  
Notes
2015-09-10 15:42:571ST REVIEW: FBC 2014 5TH ED. NEC 2011 RESIDENTIAL 5TH
 ED.
  
 PLEASE REVISE PLAN TO CITE THEAPPLICABLE CODE IN EFFECT
 ABOVE.
  
 NOTE THE PLANS MUST BE SPECIFIC AS TO THE WORK TO BE
 INCLUDED IN THE SCOPE. SHOW NEW AND CORECTED WORK.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS
 SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING
 OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2016-01-08 Cont ID  
Sent By pleduc Date 2016-01-08 Time   Rev Time 0.00
Received By pleduc Date 2016-01-08 Time 12:27 Sent To  
Notes
2016-01-05 17:05:49NEW DRAWINGS SUBMITTED. JG.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-09-18 Cont ID  
Sent By pleduc Date 2015-09-18 Time   Rev Time 0.00
Received By pleduc Date 2015-09-18 Time 08:33 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-08-31 Cont ID  
Sent By pleduc Date 2015-08-31 Time   Rev Time 0.00
Received By pleduc Date 2015-08-31 Time 11:00 Sent To  
Notes
2015-08-31 11:19:08THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF
 THE 5TH EDITION OF FLORIDA FIRE PREVENTION CODE
 INCLUDING THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND
 ALL OTHER APPLICABLE CODES OR STANDARDS.
 ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION.
  
 2) PROVIDE CORRECT ADDRESS OR APARTMENT NUMBER.
  
 3) ALL FIRE ALARM WORK SHALL BE DONE UNDER SEPARATE
 SHOP DRAWINGS.
  
 4) ADDRESS BUILDING COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2016-01-28 Cont ID  
Sent By cpuell Date 2016-01-28 Time 17:34 Rev Time 0.00
Received By cpuell Date 2016-01-22 Time 08:15 Sent To  
Notes
2016-01-25 08:33:31B33

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-01-21 Cont ID  
Sent By lmarchan Date 2016-01-21 Time 08:02 Rev Time 0.00
Received By lmarchan Date 2015-12-23 Time 15:32 Sent To B
Notes
2016-01-07 12:03:481/7/16 NEW PLANS SUBMITTED. SENT TO B33 SHELF FOR
 REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-12-17 Cont ID  
Sent By lmarchan Date 2015-12-17 Time 13:32 Rev Time 0.00
Received By lmarchan Date 2015-12-11 Time 09:10 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-10-06 Cont ID  
Sent By skennedy Date 2015-10-06 Time 08:53 Rev Time 0.00
Received By skennedy Date 2015-09-16 Time 13:28 Sent To  
Notes
2015-09-16 13:28:43B20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-10 Cont ID  
Sent By skennedy Date 2015-09-10 Time 15:43 Rev Time 0.00
Received By skennedy Date 2015-06-30 Time 09:58 Sent To  
Notes
2015-08-27 09:57:208/27/15 SENT TO B33 SHELF FOR REVIEW. THIS APPLICATION
 IS FOR APARTMENT BUILDING NOT R3. JG.

Review Stop P PLUMBING
Rev No 4 Status P Date 2016-01-26 Cont ID  
Sent By gjohnson Date 2016-01-26 Time 12:43 Rev Time 0.00
Received By gjohnson Date 2016-01-26 Time 12:43 Sent To  
Notes
2016-01-25 16:32:25NEW DRAWINGS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-01-13 Cont ID  
Sent By gjohnson Date 2016-01-13 Time 15:14 Rev Time 0.00
Received By gjohnson Date 2016-01-13 Time 15:10 Sent To  
Notes
2016-01-05 17:07:24NEW DRAWINGS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-10-05 Cont ID  
Sent By gjohnson Date 2015-10-05 Time 16:26 Rev Time 0.00
Received By gjohnson Date 2015-10-05 Time 16:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-08-27 Cont ID  
Sent By gjohnson Date 2015-07-22 Time 14:17 Rev Time 0.00
Received By gjohnson Date 2015-08-26 Time 13:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved