Plan Review Details - Permit 15061335
Plan Review Stops For Permit 15061335
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-10-27 Cont ID  
Sent By rmcdouga Date 2015-10-27 Time 18:44 Rev Time 0.00
Received By rmcdouga Date 2015-10-27 Time 18:16 Sent To  
Notes
2015-10-27 18:44:06APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED
 PROVISIONALLY. FAILURE TO CORRECT THE LISTED
 DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL
 RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF
 RE-INSPECTION FEE(S).
 1) SUBMIT SIGNED AND SEALED RAS 117 ENHANCED FASTENING
 CALCULATIONS FOR THE CERTAINTEED MODIFIED ROOFING
 SYSTEM (NOA NO.14-0224.03) WITH 170MPH EXPOSURE C.
 2) SUBMIT FASTENING DETAILS AND ADHESIVE PRODUCT
 APPROVALS FOR SANTEFE 'S' CLAY TILE (NOA
 NO.10-1005.15).
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-08-26 Cont ID  
Sent By rmcdouga Date 2015-08-26 Time 17:35 Rev Time 0.00
Received By rmcdouga Date 2015-08-24 Time 16:11 Sent To  
Notes
2015-08-26 15:10:24PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE CONSTRUCTION TYPE SPECIFIED ON SHEET AS-1 IS
 TYPE III-B. THIS CONSTRUCTION TYPE REQUIRES THE
 EXTERIOR BEARING WALLS TO HAVE A 2 HOUR FIRE RATING.
 THE CONSTRUCTION FOR THIS SINGLE FAMILY DWELLING IS
 TYPE V-B. FBC 602
  
 2) THE 2010 FBC REFERENCES THE 2008 EDITIONS OF
 ACI-530, ASCE 5, TMS 402,
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-08-24 Cont ID  
Sent By rmcdouga Date 2015-08-24 Time 18:44 Rev Time 0.00
Received By rmcdouga Date 2015-08-24 Time 18:03 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2015-07-24 Cont ID  
Sent By fmittner Date 2015-07-24 Time 09:01 Rev Time 0.00
Received By fmittner Date 2015-07-24 Time 09:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-10-27 Cont ID  
Sent By rmcdouga Date 2015-10-27 Time 18:45 Rev Time 0.00
Received By rmcdouga Date 2015-10-13 Time 14:05 Sent To  
Notes
2015-10-14 14:05:46RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-08-26 Cont ID  
Sent By rmcdouga Date 2015-08-26 Time 17:35 Rev Time 0.00
Received By rmcdouga Date 2015-06-29 Time 14:39 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2015-10-27 Cont ID  
Sent By rmcdouga Date 2015-10-27 Time 18:04 Rev Time 0.00
Received By rmcdouga Date 2015-10-27 Time 17:44 Sent To  
Notes
2015-10-27 18:07:49MU-2015-20868, PAID $9,825.49

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-08-24 Cont ID  
Sent By rmcdouga Date 2015-08-24 Time 16:12 Rev Time 0.00
Received By rmcdouga Date 2015-08-24 Time 16:12 Sent To  
Notes
2015-08-24 16:13:02BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2015-08-25 Cont ID  
Sent By rmcdouga Date 2015-08-25 Time 08:56 Rev Time 0.00
Received By rmcdouga Date 2015-08-24 Time 18:59 Sent To  
Notes
2015-08-25 09:06:39APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED
 PROVISIONALLY. FAILURE TO CORRECT THE LISTED
 DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL
 RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF
 RE-INSPECTION FEE(S).
 1) FBC-R - M 1602.4 PROVIDE BALANCED AIR RETURN AT
 BEDROOMS. THERE IS AN 8" DIA. SUPPLY DUCT TO THE MASTER
 BEDROOM AND BATH. IN ORDER TO PROVIDE THE REQUIRED
 1-1/2 TIMES THE CROSS SECTIONAL AREA OF THE SUPPLY, THE
 TRANSFER DUCT IS REQUIRED TO HAVE A 10" DIAMETER.

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-07-21 Cont ID  
Sent By skennedy Date 2015-07-21 Time 14:43 Rev Time 0.00
Received By skennedy Date 2015-07-21 Time 14:43 Sent To  
Notes
2015-07-21 14:44:15REVIEW BY GJOHNSON

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2015-10-27 Cont ID  
Sent By rmcdouga Date 2015-10-27 Time 18:29 Rev Time 0.00
Received By rmcdouga Date 2015-10-27 Time 18:18 Sent To  
Notes
2015-10-27 18:29:49SANTEFE SPANISH 'S' TILE, NOA NO. 10-1005.15
 CERTAINTEED MODIFIED BITUMEN ROOFING SYSTEM, NOA NO.
 14-0224.03

Review Stop Z ZONING
Rev No 1 Status P Date 2015-07-24 Cont ID  
Sent By fmittner Date 2015-07-24 Time 09:02 Rev Time 0.00
Received By fmittner Date 2015-07-24 Time 09:02 Sent To  
Notes
***NONE***