| Plan Review Stops For Permit 15061335 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-27 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-27 |
Time |
18:16 |
Sent To |
|
|
| Notes |
| 2015-10-27 18:44:06 | APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED | | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | | DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL | | | RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF | | | RE-INSPECTION FEE(S). | | | 1) SUBMIT SIGNED AND SEALED RAS 117 ENHANCED FASTENING | | | CALCULATIONS FOR THE CERTAINTEED MODIFIED ROOFING | | | SYSTEM (NOA NO.14-0224.03) WITH 170MPH EXPOSURE C. | | | 2) SUBMIT FASTENING DETAILS AND ADHESIVE PRODUCT | | | APPROVALS FOR SANTEFE 'S' CLAY TILE (NOA | | | NO.10-1005.15). | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-08-26 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-08-24 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2015-08-26 15:10:24 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE CONSTRUCTION TYPE SPECIFIED ON SHEET AS-1 IS | | | TYPE III-B. THIS CONSTRUCTION TYPE REQUIRES THE | | | EXTERIOR BEARING WALLS TO HAVE A 2 HOUR FIRE RATING. | | | THE CONSTRUCTION FOR THIS SINGLE FAMILY DWELLING IS | | | TYPE V-B. FBC 602 | | | | | | 2) THE 2010 FBC REFERENCES THE 2008 EDITIONS OF | | | ACI-530, ASCE 5, TMS 402, | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-08-24 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-08-24 |
Time |
18:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-07-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-07-24 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-07-24 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-27 |
Time |
18:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-13 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2015-10-14 14:05:46 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-08-26 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-29 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-27 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-27 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2015-10-27 18:07:49 | MU-2015-20868, PAID $9,825.49 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-08-24 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-08-24 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2015-08-24 16:13:02 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2015-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-08-25 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-08-24 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2015-08-25 09:06:39 | APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED | | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | | DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL | | | RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF | | | RE-INSPECTION FEE(S). | | | 1) FBC-R - M 1602.4 PROVIDE BALANCED AIR RETURN AT | | | BEDROOMS. THERE IS AN 8" DIA. SUPPLY DUCT TO THE MASTER | | | BEDROOM AND BATH. IN ORDER TO PROVIDE THE REQUIRED | | | 1-1/2 TIMES THE CROSS SECTIONAL AREA OF THE SUPPLY, THE | | | TRANSFER DUCT IS REQUIRED TO HAVE A 10" DIAMETER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-07-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-07-21 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-07-21 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2015-07-21 14:44:15 | REVIEW BY GJOHNSON |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2015-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-27 |
Time |
18:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-27 |
Time |
18:18 |
Sent To |
|
|
| Notes |
| 2015-10-27 18:29:49 | SANTEFE SPANISH 'S' TILE, NOA NO. 10-1005.15 | | | CERTAINTEED MODIFIED BITUMEN ROOFING SYSTEM, NOA NO. | | | 14-0224.03 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-07-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-07-24 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-07-24 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|