| Plan Review Stops For Permit 15061267 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-10-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-10-31 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-10-30 |
Time |
17:51 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-08-27 |
|
|
Cont ID |
|
| Sent By |
S. Hill |
Date |
2015-08-27 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-27 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2015-08-27 07:39:34 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. VALUE IS TOO LOW. BASED ON PLANS AND VIOLATION, | | | HOUSE HAS BEEN REWIRED, INTERIOR RENOVATION, NEW | | | FRAMING AND DRYWALL, DECK, PLUMBING, VALUE TO DATE PER | | | CONTRACTOR IS $14,600. | | | | | | PROVIDE AN ACCURATE MARKET VALUE OF ALL WORK. FBC 109. | | | | | | 2. THERE ARE REFERENCES TO FBC R ON THE PLAN; THIS IS | | | NOT APPLICABLE TO THIS STRUCTURE WHICH HAS THREE UNITS. | | | | | | 3. REVISE PLAN TO INDICATE METHOD OF COMPLIANCE, FBC | | | 2010 EXISTING BUILDING 101.5, AND REVISE PLAN TO SHOW | | | COMPLIANCE WITH ALL REQUIREMENTS. THIS APPEARS TO BE A | | | LEVEL 3 ALTERATION. IT IS NOT POSSIBLE TO COMPLETE AN | | | ACCURATE REVIEW WITHOUT THIS INFORMATION. ALSO DUE TO | | | WORK DONE WITHOUT PERMITS IT IS NOT POSSIBLE TO | | | DETERMINE WHAT IS ACTUALLY EXISTING AND WHAT WAS | | | INSTALLED WITHOUT PERMIT WHICH IS NOW TO BE INCLUDED IN | | | THIS RENOVATION. | | | | | | 4. PLANS SHOW AC, BUT NO MECHANICAL INFORMATION | | | PROVIDED AND NO EVIDENCE OF A MECHANICAL PERMIT FOR | | | THIS STRUCTURE, FBC 105. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-02-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-02-19 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-02-18 |
Time |
15:42 |
Sent To |
I |
|
| Notes |
| 2016-02-19 10:21:10 | ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN | | | SATISFACTORILY ADDRESSED. I SPOKE WITH THE DESIGN | | | PROFESSIONAL TO CORRECT THE PANEL LABELS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-11-17 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-11-17 |
Time |
21:14 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-11-17 |
Time |
20:11 |
Sent To |
I |
|
| Notes |
| 2015-11-17 21:15:15 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | 1. PLEASE NOTE THAT THE USE OF A CO DETECTOR IS NOT A | | | VIOLATION. THOUGH IT IS NOT A REQUIREMENT BECAUSE THERE | | | ARE NO ATTACHED GARAGES OR GAS APPLIANCES, THE EXTRA | | | PROTECTION IS WELL WORTH THE EFFORT. | | | 2. PREVIOUSLY YOU REFERRED TO ?ROMEX? NOW YOU REFER TO | | | ?BX? PLEASE NOTE THAT THESE ARE NOT APPROVED WIRING | | | METHODS. THE CODE DOES NOT RECOGNIZE ROMEX OR BX. | | | CORRECT YOUR NOTE ACCORDINGLY. | | | 3. INDICATE HOW THE REAR STAIRS ARE BEING ILLUMINATED | | | AND SWITCHED. A WALL SCONCE ON THE EXTERIOR DOOR IS NOT | | | SUFFICIENT TO ILLUMINATE THE COMPLETE STAIRWAY. | | | FURTHERMORE, SHOW THE AUTOMATIC/REMOTE SWITCHING. | | | 4. CORRECT THE WET LOCATION NOTES AS THE QUOTED CODE | | | SECTION EITHER DO NOT EXIST OR ARE INAPPLICABLE. | | | 5. NEC REQUIRES A LIGHT ON THE OUTSIDE OF THE FRONT | | | DOOR OF THE BLDG. | | | 6. ALL PANELS ARE LABELED ?C?, CORRECT ACCORDINGLY. | | | 7. THE NOTES CALL FOR A 100 AMP HOUSE PANEL AND THE | | | PLANS SHOW A 150 AMP PANEL WITH A CONNECTED LOAD OF 150 | | | AMP. CORRECT ACCORDINGLY. | | | 8. PROVIDE LOAD CALCS AS REQUIRED BY NEC. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | | INSERT CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-07-23 |
|
|
Cont ID |
|
| Sent By |
D Hayes |
Date |
2015-07-23 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-07-23 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2015-08-20 12:53:28 | SHILL'S DESK | | 2015-07-23 17:20:55 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE | | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | | THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE | | | CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW. | | | | | | 1. ROMEX, AS MENTIONED IN YOUR NOTES IS INTENDED AS A | | | CABLE TYPE, ROMEX IS A BRAND NAME AND NOT A TYPE OF | | | LISTED CABLE; USE OF NM, NMC OR NMS ETC. | | | 2. YOU SHALL PROVIDE SMOKE DETECTORS AS PER FBC-R 314. | | | 3. DISCONNECTS FOR AHU SHALL BE MADE ACCESSIBLE. | | | 4. NEC 314.27(A) LUMINAIRE OUTLETS. BOXES USED AT | | | LUMINAIRE OR LAMPHOLDER OUTLETS IN A CEILING SHALL BE | | | REQUIRED TO SUPPORT A LUMINAIRE WEIGHING A MINIMUM OF | | | 50 LB. | | | 5. REAR STAIRS SHALL HAVE THE REQUIRED ILLUMINATION AND | | | BE SWITCHED FROM BOTH THE TOP AND BOTTOM OF STAIRS. | | | 6. PROVIDE A HOUSE METER & PANEL FOR COMMON LOADS SUCH | | | AS HOUSE LIGHTING (CORRIDORS AND STAIRS, EMERGENCY | | | LIGHTING AND SERVICE OUTLETS FOR CONDENSING UNITS.) | | | 7. CORRECT RISER DIAGRAM TO CONFIRM MAIN SERVICE | | | DISCONNECTS ARE GROUPED TOGETHER AND NEXT TO THE | | | ELECTRIC SERVICE METERS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-10-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-10-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-10-28 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-06-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-06-30 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2015-06-30 15:52:51 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE STAIR AND RAILING DETAIL FOR BOTH STAIRS. | | | EXISTING STAIRS SHALL COMPLY WITH NFPA 101, CHAPTER 31, | | | CHAPTER 7, 7.2.2.2.1.1 (2). | | | | | | 2. THERE APPEARS TO BE CLOSETS UNDER THE LANDING OF THE | | | EXIT STAIR. | | | | | | 7.2.2.5.3 USABLE SPACE | | | | | | ENCLOSED, USABLE SPACE SHALL BE PERMITTED UNDER STAIRS, | | | PROVIDED THAT ALL OF THE FOLLOWING CRITIERIA ARE MET: | | | | | | (1) THE SPACE SHALL BE SEPARATED FROM THE ENCLOSURE BY | | | THE SAME FIRE RESISTANCE AS THE EXIT ENCLOSURE. | | | | | | (2) ENTRANCE TO THE ENCLOSED, USABLE SPACE SHALL NOT BE | | | FROM WITHIN THE STAIR ENCLOSURE. | | | | | | (3) THE SPACE IS NOT USED FOR STORAGE OF FLAMMABLE, OR | | | OTHERWISE HAZARDOUS MATERIALS. | | | | | | 3. FOR THE DOORS WITHIN THE EXIT STAIRWAY AND EXIT PATH | | | (2ND FL) PROVIDE A DOOR SCHEDULE INCLUDING HARDWARE | | | MEETING THE REQUIREMENTSOF NFPA 31, 31.2.2.1.2 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-10-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-10-07 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-10-07 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-07-21 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-07-21 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-07-21 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2015-07-21 16:33:10 | NEED INFORMATION IF ANY OPENING CHANGES ARE OCCURING ON | | | WINDOWS. PLANS INDICATE WINDOWS WILL BE PERMITTED | | | SEPERATELY BUT FRAMING WILL BE COMPLETED UNDER THIS | | | PERMIT. NEEDS BETTER COORDINATION. QUESTIONS CONTACT | | | FRIEDERIKE MITTNER AT 8221457. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-02-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-02-19 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-02-12 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2016-02-19 10:22:27 | 2/19/16 PASSED ELECTRICAL REVIEW AS NOTED. CONTRACTOR | | | OUT FRONT TO PICK UP PERMIT. SENT DIRECTLY TO SP. MA | | 2016-02-16 09:55:12 | RESUB OF REVISION ROUTED TO MALBARRAN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-11-17 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-11-17 |
Time |
21:15 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-05 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2015-11-17 21:16:15 | 11/17/15 FAILED ELECTRICAL REVIEW. CONTRACTOR NOTIFIED | | | VIA EMAIL. SENT TO SHILL'S DESK. MA | | 2015-10-05 12:39:37 | C37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-08-27 |
Time |
07:39 |
Rev Time |
|
| Received By |
shill |
Date |
2015-06-26 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-06-29 10:02:14 | SENT TO C38. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-10-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-10-21 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-10-21 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-07-09 |
|
|
Cont ID |
|
| Sent By |
C Cole |
Date |
2015-07-09 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-07-09 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2015-07-09 10:40:57 | 1ST REVIEW: FBC 2010 MECHANICAL | | | 7/9/15 | | | | | | 1) PROVIDE DRYER EXHAUST PLANS FOR THE LAUNDRY | | | APPLIANCES ON THE PORCH AND IN THE APT. CLOSETS. SHOW | | | THE TYPE AND SIZE OF EXHAUST DUCTS, DUCT RUN AND TOTAL | | | LENGTH MEASUREMENTS, AND TERMINATION LOCATIONS- SEE | | | SECTION 504 FBC-10 MECHANICAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-10-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-10-21 |
Time |
03:00 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-10-21 |
Time |
02:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-07-22 |
|
|
Cont ID |
|
| Sent By |
TKL |
Date |
2015-07-22 |
Time |
05:06 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-07-22 |
Time |
04:46 |
Sent To |
|
|
| Notes |
| 2015-07-22 04:32:44 | 1) THE PLANS SHOW THE WASHER/DRYERS ON A PORCH. IS THIS | | | PORCH OPEN TO THE ELEMENTS? IF SO, SUBMIT APPLIANCE | | | SPECIFICATIONS/INSTALLATION MANUAL THAT SHOWS THAT THEY | | | CAN BE INSTALLED IN THIS TYPE OF ENVIRONMENT. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 2) SUBMIT A SANITARY AND WATER RISER FOR THE ADDITION | | | OF THE WASHING MACHINES.WPB AMEND. TO FBC SEC. | | | 107.3.5.1.3. | | | 3) THIS STRUCTURE DOES NOT FALL UNDER THE RESIDENTIAL | | | BUILDING CODE SO THE WASHING MACINE STANDPIPE SHALL | | | CONNECT TO A 3" STACK PER THE 2010 FBC-PLUMBING, | | | SEC.406.3. | | | 4) SUBMIT MANUFACTURER SPECIFICATIONS FOR THE TANKLESS | | | WATER HEATERS TO BE INSTALLED.THEY ARE ALSO SHOWN AS | | | BEING LOCATED ON THE PORCH. IF THE PORCH IS OPEN TO THE | | | ELEMENTS, SUBMIT DOCUMENTATION FROM THE MANUFACTURER | | | THAT THE UNIT CAN BE INSTALLED EXPOSED TO THE ELEMENTS. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-10-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-10-07 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-10-07 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-07-21 |
|
|
Cont ID |
|
| Sent By |
FMittner |
Date |
2015-07-21 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-07-21 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|