Plan Review Details - Permit 15061210
Plan Review Stops For Permit 15061210
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-08-25 Cont ID  
Sent By cthroop Date 2016-08-25 Time 11:01 Rev Time 0.00
Received By cthroop Date 2016-08-25 Time 11:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-11-06 Cont ID  
Sent By cthroop Date 2015-11-06 Time 15:15 Rev Time 0.00
Received By cthroop Date 2015-11-06 Time 15:15 Sent To  
Notes
2015-11-06 15:38:11CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 PLEASE PROVIDE THE FOLLOWING FASTENER SCHEDULES:
 BASE PLATE TO FOUNDATION
 TOP PLATE TO TRUSS
 ROOF SHEATHING
  
 PLEASE PROVIDE EXTERIOR WALL DETAIL (STRUCTURAL PLAN
 REQUIRES 5/8" CDX, ENGINEERED PLANS REQUIRE 1/2" CDX)
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-08-19 Cont ID  
Sent By skennedy Date 2015-08-19 Time 10:13 Rev Time 0.00
Received By skennedy Date 2015-08-19 Time 08:29 Sent To  
Notes
2015-08-19 08:36:391ST REVIEW: FBC 2010
  
 CURRENTLY UNDER REVIEW:
  
 THE PLANS LACK DETAIL AND CLARITY:
  
 FBC 107.2.1 CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. A COMPLETE REVIEW CANNOT BE PERFORMED.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR
 SUBMITTALS.
  
 R401.4 SOIL TESTS - PROVIDE A SOILS ANALYSIS
  
 FBC 107 & FBCR 601 - WALL CONSTRUCTION; PROVIDE DETAILS
 TO CLARIFY OR SPECIFY THE FOLLOWING: HEADERS,
 TRIMMER/CRIPPLE STUDS, A WALL SHEATHING NAILING
 SCHEDULE. PROVIDE A DETAIL TO TERMINATE THE STUCCO AT
 THE FOUNDATION TO DEMONSTRATE COMPLIANCE WITH FBCR704,
 TERMITE INSPECTION. PROVIDE WINDOW AND DOOR
 INSTALLATION DETAILS TO MEET ANCHORAGE OF FBCR 612.10 .
 DESIGN PRESSURES FOR WINDOW #3 APPEAR LOW AS THEY ARE
 LOCATED IN ZONE 5. R703.6.3 TWO LAYERS OF WATER
 RESISTANT BARRIER ARE REQUIRED.
  
 FBC 107 & FBCR 801 - ROOF CONSTRUCTION - PROVIDE
 DETAILS TO CLARIFY OR SPECIFY THE FOLLOWING: ROOF
 VENTILATION PER R806, ROOF DRAINAGE, NOTE: THE ROOF
 FRAMING DETAIL AND ROOF FRAMING PLAN ARE IN CONFLICT AS
 TO THE DIRECTION OF RUN OF THE MAIN ROOF TRUSSES. YOU
 SHOULD PROVIDE THE ROOF TRUSS ENGINEERING NOW AND THE
 DESIGNER SHOULD EVALUATE THE ROOF FRAMING PLAN VS. THE
 TRUSS DESSIGN. SPECIFY THE ROOF SHEATHING NAIL LENGTH
 AND SHANK TYPE. FURTHER SPECIFT THE PARAPET
 CONSTRUCTION.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-07-11 Cont ID  
Sent By mvaldes Date 2016-07-11 Time 17:49 Rev Time 0.00
Received By mvaldes Date 2016-07-11 Time 17:49 Sent To  
Notes
2016-07-11 17:50:11REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 PASSED WITH THE FOLLOWING PROVISO
  
 - NEC 110.26(D) ILLUMINATION. ILLUMINATION SHALL BE
 PROVIDED FOR ALL WORKING SPACES ABOUT SERVICE
 EQUIPMENT, SWITCHBOARDS, PANELBOARDS.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-11-19 Cont ID  
Sent By mvaldes Date 2015-11-19 Time 10:14 Rev Time 0.00
Received By mvaldes Date 2015-11-19 Time 10:13 Sent To  
Notes
2015-11-19 10:33:501ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6700
 [email protected]
  
  
  
 FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN 10
 FEET OF EACH SLEEPING ROOM.
 NEC 210.12B - OUTLETS TO BE AFCI PROTECTED.
 NEC 220.82 A AMPACITY OF 100 AMPS OR GREATER/ COULD
 ONLY FILL BREAKER 80 % OF LOAD
 PROVIDE GROUNTING ELECTRODE IN ATTACHED BUILDING PER
 NEC 250
 FBC- 107.3.5.3 ? ELECTRIC SERVICE RISER WITH WIRE
 SIZES, CONDUIT DETAIL AND GROUNDING DETAIL. COMPLETE
 LOAD CALCULATIONS, PANEL SCHEDULES AND SHOW CIRCUITS ON
 FLOOR PLAN.
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-08-19 Cont ID  
Sent By skennedy Date 2015-08-19 Time 10:14 Rev Time 0.00
Received By skennedy Date 2015-08-19 Time 10:14 Sent To  
Notes
2015-08-19 10:29:021ST REVIEW: FBC 2010
  
 REVISE PLAN TO INDICATE COMPLIANCE WITH THE FOLLOWING:
  
 NEC 210.52(A)(1)&(2) OUTLET SPACING, IT APPEARS SOME
 POINTS ALONG THE WALL EXCEED 6? FROM AN OUTLET
  
 NEC 210.52 (B) (3) - KITCHEN COUNTER TOP RECEPTACLES
 SHALL BE SUPPLIED BY NO FEWER THAN TWO SMALL APPLIANCE
 BRANCH CIRCUITS.
  
 NEC 210.63 - PROVIDE A GFI SERVICE OUTLET FOR WITHIN
 25? OF MECHANICAL EQUIPMENT
  
 NEC 406.11- PROVIDE TAMPER RESISTANT RECEPTACLES.
  
 FBC 1006.1.1 PER FBC-R, T-E3403
 ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED IN
 ACCORDANCE WITH THIS SECTION FOR EVERY BUILDING AND
 STRUCTURE, BEDROOM EXIT..
  
 ADDITIONALLY, NO CIRCUIT OR DICCONNECT IS SHOWN FOR THE
 A/C EQUIPMET OR THE WATER HEATER, THE LOAD CALCULATION
 DOES NOT ACCOUNT FOR THESE LOADS.
  
 INDICATE THE LOCATION OF THE SERVICE. IS THE 60AMP
 PANEL FOR THE ACCESSORY STRUCTURE FED FROM THE SERVICE
 TO THE HOUSE OR IS THERE TO BE A SEPARATE SERVICE. IS
 THIS AN ACCESSORY BUILDING OR A SEPARATE DWELLING UNIT?
 PROVIDE AN ACCURATE SERVICE RISER DIAGRAM,. ACCURATE
 LOAD CALCULATIONS, AND PANEL SCHEDULES.
  
 NOTE, A COMPLETE REVIEW CANNOT BE PERFORMED DUE TO THE
 LACK OF INFORMATION PROVIDED.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2016-08-31 Cont ID  
Sent By fmittner Date 2016-08-31 Time 14:43 Rev Time 0.00
Received By fmittner Date 2016-08-31 Time 14:43 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status F Date 2016-07-08 Cont ID  
Sent By fmittner Date 2016-07-08 Time 14:57 Rev Time 0.00
Received By fmittner Date 2016-07-08 Time 14:57 Sent To  
Notes
2016-07-08 14:58:43SOUTH FACING WINDOW DOES NOT MATCH PROPORATIONS/STYLE
 OF WHAT HPB REVIEWED. SHALL BE VERTICALLY ORIENTED WITH
 PENT ROOF. QUESTIONS PLEASE CONTACT FRIEDERIKE MITTNER
 AT 822-1457.

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2015-11-17 Cont ID  
Sent By ccole Date 2015-11-09 Time 11:04 Rev Time 0.00
Received By fmittner Date 2015-11-17 Time 11:47 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2015-07-21 Cont ID  
Sent By fmittner Date 2015-07-21 Time 09:42 Rev Time 0.00
Received By fmittner Date 2015-07-21 Time 09:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2016-10-31 Cont ID  
Sent By cthroop Date 2016-10-31 Time 08:55 Rev Time 0.00
Received By cthroop Date 2016-10-27 Time 13:22 Sent To  
Notes
2016-10-28 13:23:12RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-10-28 Cont ID  
Sent By lmarchan Date 2016-10-28 Time 13:22 Rev Time 0.00
Received By lmarchan Date 2016-10-14 Time 07:24 Sent To  
Notes
2016-10-17 07:26:06JVALIDO'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-08-25 Cont ID  
Sent By cthroop Date 2016-08-25 Time 11:01 Rev Time 0.00
Received By cthroop Date 2016-06-16 Time 12:48 Sent To  
Notes
2016-06-17 12:48:44R27

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-11-19 Cont ID  
Sent By lmarchan Date 2015-11-19 Time 10:50 Rev Time 0.00
Received By lmarchan Date 2015-09-10 Time 12:40 Sent To  
Notes
2015-09-10 12:40:55RESUB ROUTED TO SKENNEDY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-08-19 Cont ID  
Sent By skennedy Date 2015-08-19 Time 10:29 Rev Time 0.00
Received By skennedy Date 2015-06-25 Time 16:35 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-10-31 Cont ID  
Sent By cthroop Date 2016-10-31 Time 08:55 Rev Time 0.00
Received By cthroop Date 2016-10-31 Time 08:55 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-08-19 Cont ID  
Sent By skennedy Date 2015-08-19 Time 08:05 Rev Time 0.00
Received By skennedy Date 2015-08-19 Time 08:05 Sent To  
Notes
2015-08-19 08:07:08PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND
 TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED
 WITH A COPY OF RECEIPT AS APPLICABLE.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2016-10-17 Cont ID  
Sent By jvalido Date 2016-10-17 Time 17:54 Rev Time 0.00
Received By jvalido Date 2016-10-17 Time 17:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2016-08-18 Cont ID  
Sent By jvalido Date 2016-08-18 Time 19:25 Rev Time 0.00
Received By jvalido Date 2016-08-18 Time 18:57 Sent To  
Notes
2016-08-18 19:17:44CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 R403.6.1 - HEATING AND COOLING EQUIPMENT SHALL BE SIZED
 IN ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT
 LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR
 OTHER APPROVED HEATING AND COOLING CALCULATION
 METHODOLOGIES, BASED ON BUILDING LOADS FOR THE
 DIRECTIONAL ORIENTATION OF THE BUILDING. THE
 MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR AND INDOOR
 UNITS (IF SPLIT SYSTEM) SHALL BE SUBMITTED ALONG WITH
 THE SENSIBLE AND TOTAL COOLING CAPACITIES AT THE DESIGN
 CONDITIONS DESCRIBED IN SECTION R302.1. THIS CODE DOES
 NOT ALLOW DESIGNER SAFETY FACTORS, PROVISIONS FOR
 FUTURE EXPANSION OR OTHER FACTORS WHICH AFFECT
 EQUIPMENT SIZING. SYSTEM SIZING CALCULATIONS SHALL NOT
 INCLUDE LOADS CREATED BY LOCAL INTERMITTENT MECHANICAL
 VENTILATION SUCH AS STANDARD KITCHEN AND BATHROOM
 EXHAUST SYSTEMS.
  
 (1) PROVIDE EQUIPMENT SCHEDULE AS PER R403.6.1.
 (2) PROVIDE EQUIPMENT INFORMATION ON EXHAUST FAN IN
 BATHROOM.
 (3) PROVIDE TIE DOWN DETAIL ON PLANS OR MANUFACTURER
 DATA INFORMATION FOR THE SPECIFIC TIE DOWN DEVICES
 BEING USED.
  
 FLORIDA ENERGY CODE FBC 2014
  
 (4) PROVIDE AHRI
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-11-09 Cont ID  
Sent By ccole Date 2015-11-09 Time 11:04 Rev Time 0.00
Received By ccole Date 2015-11-09 Time 10:33 Sent To HIST
Notes
2015-11-09 10:37:372ND REVIEW: FBC 2014 MECHANICAL
 PERMIT #15061210
 11/9/15
  
 1) SHEET 3: PLEASE SHOW THE LOCATION OF THE AC
 CONDENSER ON THE PLANS, AND PROVIDE STRUCTURAL DETAILS
 FOR THE PAD AND TIE DOWN OF THE UNIT- SEE SECTION
 M1307.2.1 FBC-10 RESIDENTIAL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-08-19 Cont ID  
Sent By skennedy Date 2015-08-19 Time 10:08 Rev Time 0.00
Received By skennedy Date 2015-08-19 Time 10:08 Sent To  
Notes
2015-08-19 10:13:441ST REVIEW: FBC 2010
  
 PROVIDE PRODUCT INFORMATION FOR THE MECHANICAL
 EQUIPMENT TO INCLUDE AN AHRI & INSTALLATION DETAILS.
 DEMONSTRATE ANY ELECTRICAL, WALL FRAMING, AND OUTDOOR
 UNIT SUPPORT REQUIREMENTS.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-07-22 Cont ID  
Sent By gjohnson Date 2016-07-22 Time 17:49 Rev Time 0.00
Received By gjohnson Date 2016-07-22 Time 17:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-09-11 Cont ID  
Sent By tklarge Date 2015-09-11 Time 05:23 Rev Time 0.00
Received By tklarge Date 2015-09-11 Time 04:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-07-16 Cont ID  
Sent By tklarge Date 2015-07-16 Time 02:40 Rev Time 0.00
Received By tklarge Date 2015-07-16 Time 02:24 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2016-08-25 Cont ID  
Sent By cthroop Date 2016-08-25 Time 11:01 Rev Time 0.00
Received By cthroop Date 2016-08-25 Time 11:01 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2015-11-06 Cont ID  
Sent By cthroop Date 2015-11-06 Time 15:38 Rev Time 0.00
Received By cthroop Date 2015-11-06 Time 15:38 Sent To E
Notes
2015-11-06 15:41:19CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 PLEASE PROVIDE ROOF SYSTEM FASTENER SCHEDULE PER NOTE 7
 OF NOA 14-0224.03
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2015-08-19 Cont ID  
Sent By skennedy Date 2015-08-19 Time 08:07 Rev Time 0.00
Received By skennedy Date 2015-08-19 Time 08:07 Sent To  
Notes
2015-08-19 08:25:441ST REVIEW: FBC 2010
  
 FBC 107 - FURTHER SPECIFY THE ROOFING SYSTEM TO BE USED
 FOR THE FLAT ROOF . DEMONSTRATE COMPLIANCE WITH THE
 REQUIREMENTS OF FBCR 905.9 EG: PROVIDE TIN TAG SPACING
 FOR 30# UNDERLAYMENT INCLUDING ENHANCED FASTENING FOR
 ZONES 2 & 3, NUMBER OF PLYS AND MATERIAL AND
 APPLICATION. SHOW THE ROOF DRAINAGE METHOD.
 ALTERNATIVELY, PROVIDE ROOF COVERING PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD, INCLUDE THE SYSTEM FOR TNE TYPE "S" TILE ROOF
 OVERHANG..
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2016-07-08 Cont ID  
Sent By fmittner Date 2016-07-08 Time 14:58 Rev Time 0.00
Received By fmittner Date 2016-07-08 Time 14:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2015-11-17 Cont ID  
Sent By fmittner Date 2015-11-17 Time 11:48 Rev Time 0.00
Received By fmittner Date 2015-11-17 Time 11:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-07-21 Cont ID  
Sent By fmittner Date 2015-07-21 Time 09:42 Rev Time 0.00
Received By fmittner Date 2015-07-21 Time 09:42 Sent To  
Notes
***NONE***