Plan Review Details - Permit 15061068
Plan Review Stops For Permit 15061068
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-07-22 Cont ID  
Sent By aclange Date 2015-07-22 Time 16:53 Rev Time 0.00
Received By aclange Date 2015-07-22 Time 16:53 Sent To E
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-08-10 Cont ID  
Sent By albarran Date 2015-08-10 Time 17:14 Rev Time 0.00
Received By albarran Date 2015-08-10 Time 16:37 Sent To I
Notes
2015-08-10 17:14:47IMPORTANT NOTICE: FOR FINAL ELECTRICAL INSPECTION,
 REGARDLESS IF THIS SIGN WAS CONNECTED TO NEW OR
 EXISTING POWER, FULL COMPLIANCE WITH 2008 NEC & 2010
 FBC ENERGY CONSERVATION SECTION 505.2.4 WILL BE
 REQUIRED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-07-22 Cont ID  
Sent By albarran Date 2015-07-22 Time 18:51 Rev Time 0.00
Received By albarran Date 2015-07-22 Time 18:49 Sent To I
Notes
2015-07-22 18:52:15PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS
 EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE
 MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO
 THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE
 CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW.
 1. NEC 600.6, REQUIRES THE EACH SIGN HAVE A DISCONNECT.
 2. NEC 600.6(A) REQUIRES THAT THE DISCONNECT BE WITHIN
 SIGHT OF THE SIGN.
 3. NEC ARTICLE 600 HAS SPECIFIC ELECTRICAL REQUIREMENTS
 FOR SIGNS.
 4. FBC-E 505 HAS SPECIFIC SWITCHING REQUIREMENTS FOR
 SIGNS.
  
 ALL OF THE ABOVE SHALL BE COMPLIED WITH AND REFLECTED
 ON THE ELECTRICAL PAGE FOR THIS PERMIT APPLICATION.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-08-10 Cont ID  
Sent By albarran Date 2015-08-10 Time 17:15 Rev Time 0.00
Received By albarran Date 2015-08-04 Time 12:38 Sent To  
Notes
2015-08-10 17:17:328/10/15 - PASSED ELECTRICAL REVIEW. CONTRACTOR NOTIFIED
 VIA EMAIL. SENT TO SMALL READY BIN "R". MA
2015-08-04 12:38:47RESUB ROUTED TO MALBARRAN

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-07-22 Cont ID  
Sent By albarran Date 2015-07-22 Time 18:52 Rev Time  
Received By albarran Date   Time   Sent To  
Notes
2015-07-22 18:53:337/22/15 - FAILED ELECTRICAL REVIEW AS NOTED. CONTRACTOR
 NOTIFIED VIA EMAIL. SENT TO SMALL DENIED BIN ":R". MA
2015-06-24 10:49:05ZONING

Review Stop Z ZONING
Rev No 1 Status P Date 2015-06-25 Cont ID  
Sent By sgraham Date 2015-06-25 Time 11:16 Rev Time 0.00
Received By sgraham Date 2015-06-25 Time 11:16 Sent To B
Notes
***NONE***