Plan Review Details - Permit 15060978
Plan Review Stops For Permit 15060978
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-08-21 Cont ID  
Sent By dharvey Date 2015-08-21 Time 07:48 Rev Time 0.00
Received By dharvey Date 2015-08-21 Time 07:48 Sent To  
Notes
2015-08-21 07:52:31PLANS HAVE CARD READERS AND CCTV. PLANS UNDER 15080036.
 PLANS STAMPED WITH15080036

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-08-13 Cont ID  
Sent By wjolin Date 2015-08-13 Time 09:45 Rev Time 0.00
Received By wjolin Date 2015-08-13 Time 09:45 Sent To  
Notes
2015-08-13 09:50:10INADVERTENTLY ADDED PASS TO ELECTRICAL REVIEW STOP. 3RD
 ELECTRICAL REVIEW STOP ADDED AND PLANS PLACED IN DOUG
 HARVEY'S OFFICE.
 W. JOLIN

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-07-07 Cont ID  
Sent By   Date 2015-07-07 Time 14:23 Rev Time 0.00
Received By dhayes Date 2015-07-07 Time 08:51 Sent To FIRE
Notes
2015-07-07 14:21:177/7/2015
 PROJECT: LOW VOLTAGE. CCTV, ACCESS CONTROL, SOLID WASTE
 PERMIT#: 15060978
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW
 COMMENTS:
  
 1) THE PLANS HAVE NOT BEEN SIGNED BY THE DESIGNER. WPB
 AMENDMENTS TO FBC, 107.2.1 AND FL ADMIN CODE
 61G15-23.002 ENGINEERS
  
 2) PROVIDE AN APPLICATION FROM A CONTRACTOR LICENSED BY
 THE STATE OF FL FOR THE SCOPE OF WORK APPLIED FOR. FL
 SS 489.105
  
 3) PROVIDE MANUFACTURER PRODUCT SUBMITTALS FOR
 EQUIPMENT, COMPONENTS AND CABLES PROPOSED TO BE
 INSTALLED.
  
 4) PROVIDE UL FIRE RATED ASSEMBLIES TO BE USED FOR
 PENATRATION OF FIRE RATED SURFACES.
  
 5) INDICATE THE LOCATION FOR ANY LINE VOLTAGE POWER
 SUPPLIES PROPOSED TO BE INSTALLED. THE INSTALLATION OF
 LINE VOLTAGE CONNECTIONS SHALL BE BY OTHERS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED.
 ADDITIONAL COMMENTS MAY APPEAR IN THE NEXT REVIEW CYCLE
 THAT WERE NOT PART OF THIS REVIEW.
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-08-13 Cont ID  
Sent By wjolin Date 2015-08-13 Time 09:43 Rev Time 0.00
Received By wjolin Date 2015-08-13 Time 09:43 Sent To E
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-07-07 Cont ID  
Sent By wjolin Date 2015-07-07 Time 16:14 Rev Time 0.00
Received By wjolin Date 2015-07-07 Time 15:54 Sent To  
Notes
2015-07-07 16:10:596651 NORTH JOG ROAD
 PERMIT #15060978
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PLANS ARE NOT TO SCALE ARE VERY DIFFICULT TO READ.
  
 SUBMIT PRODUCT DATA CUTSHEETS.
  
 PLANS INDICATE WORK TO BE PERFORMED IN THE
 MAINTENANCE/WAREHOUSE BUILDING WHICH IS LOCATED AT A
 DIFFERENT ADDRESS THAN THE PERMIT APPLICATION.
  
 HOW WILL THE COMMUNICATION SYSTEM SPEAKERS BE
 INTEGRATED WITH THE FIRE ALARM SYSTEM TO AVOID SOUND
 INTERFERENCE OF THE FIRE ALARM?
  
 HOW ARE THE MAG LOCKS BEING COORDINATED WITH THE FIRE
 ALARM SYSTEM?
  
 ROUTING CONDUIT OR LOCATING SECURITY EQUIPMENT SUCH AS
 CARD READERS OR CCTV WITHIN A STAIR ENCLOSURE IS NOT
 PERMITTED BY THE LIFE SAFETY CODE.
  
 LEVEL 99 (CONTROL ROOM FLOOR) HAS SECURITY FEATURES
 THAT CONFLICT THE ARCHITECTURAL LIFE SAFETY PLAN AND
 AFFECT FREE EGRESS TO EXIT STAIRS.
  
 A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE COMPLETED
 AT THIS TIME DUE TO LACK OF INFORMATION SUBMITTED ON
 THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED DURING PLAN RESUBMISSION.
  
 DISCLAIMER: REVIEW AND APPROVAL BY THE AHJ SHALL NOT
 RELIEVE THE OWNER, CONTRACTOR, ETC. OF THE
 RESPONSIBILITY OF COMPLIANCE WITH CODE (NFPA 1, SECTION
 1.14.4). FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT
 ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED
 WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL,
 ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE
 TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
 THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A
 CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR
 VIOLATIONS OF THIS CODE.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-07-07 Cont ID  
Sent By dhayes Date 2015-07-07 Time 14:23 Rev Time 0.00
Received By dhayes Date 2015-06-22 Time   Sent To  
Notes
***NONE***