Plan Review Details - Permit 15060949
| Plan Review Stops For Permit 15060949 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-07-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-15 |
Time |
19:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-15 |
Time |
19:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-07-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-08 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-08 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2015-07-08 09:19:14 | RESIDENTIAL (R3) ROOF OVER, SECOND BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC-RESIDENTIAL | | | | | | 1- TAMKO NOA 12-0716.09 SUBMITTED FOR RECOVERY DECK | | | REQUIRES FASTENERS WITHDRAWAL RESISTANCE TEST (TAS | | | 105). SEE NOTE IN BOLD IN PAGE 17 OF 19 OF NOA | | | SUBMITTED. PROVIDE 2 COPIES OF THE TAS 105 TEST. | | | REQUIRED TO VERIFY THE CALCULATED DESIGN PRESSURES | | | REQUIRED BY SEC. R301 OF 2010 FBC-RESIDENTIAL. | | | THEN, ENGINEER TO REVISE THE RAS 117 CALCULATIONS BASED | | | ON THE TAS 105 RESULTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-06-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-06-23 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-06-23 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2015-06-23 08:09:15 | RESIDENTIAL (R3) ROOFING, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC-RESIDENTIAL | | | | | | | | | 1- PERMIT APPLICATION STATES "COVER OVER ROOF". IF THIS | | | IS A RECOVER APPLICATION, THEN NEED TO PROVIDE PRODUCT | | | APPROVAL FOR SUCH INSTALLATION. PRODUCT APPROVAL NOA | | | 13-1022.15 SUBMITTED IS NOT FOR THAT APPLICATION. | | | CLEARLY IDENTIFY SELECTED ASSEMBLY. AND, PROVIDE SIGNED | | | AND SEALED RAS 117 CALCULATIONS IF SELECTED ASSEMBLY | | | ALLOWS NAIL ENHANCING. CALCULATIONS ARE REQUIRED TO | | | MEET THE DESIGN PRESSURES OF SEC. R301.1 OF 2010 | | | FBC-RESIDENTIAL. DCA RULE 9N-3. | | | | | | 2- SELECTED ASSEMBLY FROM NOA 13-1022.15 IS FOR AN | | | INSULATED ASSEMBLY. SPECIFY INSULATION TO BE USED. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-07-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-15 |
Time |
19:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-15 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2015-07-15 15:55:27 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-07-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-08 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-07 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
|