Plan Review Details - Permit 15060928
Plan Review Stops For Permit 15060928
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-08-07 Cont ID  
Sent By jwitmer Date 2015-08-07 Time 12:00 Rev Time 0.00
Received By jwitmer Date 2015-08-07 Time 11:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-09-10 Cont ID  
Sent By Albarran Date 2015-09-10 Time 14:16 Rev Time 0.00
Received By albarran Date 2015-09-10 Time 08:06 Sent To  
Notes
2015-09-10 14:17:49ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN
 SATISFACTORILY ADDRESSED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-08-19 Cont ID  
Sent By albarran Date 2015-08-19 Time 17:57 Rev Time 0.00
Received By albarran Date 2015-08-19 Time 14:57 Sent To  
Notes
2015-08-19 17:58:33PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS
 EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE
 MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO
 THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE
 CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW.
  
 PAGE SE-1
 1. ADD A NOTE TO SPECIFY THAT ?UNLESS PRIOR
 ARRANGEMENTS ARE MADE WITH THE ELECTRICAL INSPECTOR,
 ALL TRENCHING SHALL REMAIN OPEN FOR INSPECTION. NO SITE
 TUBES WILL BE ALLOWED.?
 PAGE E-1.0
 1. NOTE 4 ON PAGE E1 SHALL BE CORRECTED TO MATCH CODE
 DICTION.
 2. THE APPLICABLE CODE IS THE 2008 EDITION OF THE NEC,
 NOT THE 2002. SERIES RATING IS ADDRESSED IN SECTION
 240.86 OF THE APPLICABLE CODE.
 PAGE E-3.0
 1. MISSING EXIT/EGRESS LIGHT.
 2. MISSING EXIT/EGRESS LIGHT.
 PAGE E-4.0
 1. PANEL H11-1 CKT 37/39/41 TO READ T11 & P11.
 2. PANEL H12-1 CKT 37/39/41 TO READ T12 & P12.
 3. PANEL H10-1 CKT 37/39/41 TO READ T14 & P14.
 4. LIGHTING CONTROL SCHEDULE H9 DOES NOT MATCH PANEL
 SCHEDULE ABOVE.
 5. LIGHTING CONTROL SCHEDULE H10 DOES NOT MATCH PANEL
 SCHEDULE ABOVE.
 6. LIGHTING CONTROL SCHEDULE H11 DOES NOT MATCH PANEL
 SCHEDULE ABOVE.
 7. LIGHTING CONTROL SCHEDULE H12 DOES NOT MATCH PANEL
 SCHEDULE ABOVE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2015-07-16 Cont ID  
Sent By cranford Date 2015-07-16 Time 14:52 Rev Time 0.00
Received By cranford Date 2015-07-16 Time 14:15 Sent To  
Notes
2015-07-16 14:52:38SEE E15040005 FOR WATER, SEWER AND DRAINAGE APPROVAL.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-07-30 Cont ID  
Sent By wjolin Date 2015-07-30 Time 10:23 Rev Time 0.00
Received By wjolin Date 2015-07-30 Time 10:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-09-10 Cont ID  
Sent By cpuell Date 2015-09-10 Time 14:20 Rev Time 0.00
Received By cpuell Date 2015-09-01 Time 08:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-08-20 Cont ID  
Sent By lmarchan Date 2015-08-19 Time 07:53 Rev Time 0.00
Received By lmarchan Date 2015-07-14 Time 15:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-09-10 Cont ID  
Sent By CCole Date 2015-09-10 Time 07:25 Rev Time 0.00
Received By ccole Date 2015-09-10 Time 07:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-07-28 Cont ID  
Sent By ccole Date 2015-07-28 Time 15:17 Rev Time 0.00
Received By ccole Date 2015-07-28 Time 15:17 Sent To  
Notes
2015-07-28 15:43:581ST REVIEW: FBC 2010 MECHANICAL
 REVISION PERMIT #15060928/ MASTER PERMIT #15020476
 7/28/15
  
 1) PROVIDE VENTILATION CALCULATIONS FOR THE WET DEPOT
 AND DRY DEPOT EXTENSIONS IN ADDITIONS IN ACCORDANCE
 WITH TABLE 403.3 FBC-10 MECHANICAL.
 2) SHOWS A MEANS OF VENTILATION FOR THE WET DEPOT
 ADDITION- SECTION 401.2.
 3) PROVIDE EQUIPMENT SCHEDULES ON THE PLANS FOR
 AU'S-25, 26, 27, 28,29 & 30. LIST THE MODEL NUMBERS,
 COOLING CAPACITIES, REFRIGERANT TYPES AND AMOUNTS IN
 LBS, EFFICIENCY RATINGS, AND ELECTRICAL DATA.
 4) SHEET RE3.1 SHOWS REFRIGERANT LEAK DETECTORS AT EACH
 AU LOCATION: A) PROVIDE EQUIPMENT SCHEDULES ON THE PLAN
 FOR THE DEVICES. B) INDICATE COMPLIANCE WITH SECTIONS
 1105.6, 1105.6.3, AND 1105.6.4- VENTILATION
 CALCULATIONS FOR NORMAL AND EMERGENCY CONDITIONS. C)
 SHOW THE LOCATIONS OF ALL MECHANICAL COMPONENTS OF THE
 VENTILATION SYSTEMS ON THE PLANS AND INCLUDE EQUIPMENT
 SCHEDULES. D) PROVIDE A SEQUENCE OF OPERATION NARRATIVE
 AND DIAGRAM ON THE PLAN CLARIFYING HOW LEAK DETECTON
 WILL ACTIVATE THE EMERGENCY VENTILATION SYSTEM.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2015-10-01 Cont ID  
Sent By skennedy Date 2015-10-01 Time 10:27 Rev Time 0.00
Received By skennedy Date 2015-10-01 Time 10:27 Sent To  
Notes
***NONE***