| Plan Review Stops For Permit 15060911 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-26 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-26 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2015-08-26 09:53:02 | BUILDING PLAN REVIEW | | | PERMIT: 15060911 | | | ADD: 1220 ORTEGA RD | | | CONT: WILBUR HOBGOOD CONST. | | | TEL: (561)691-9686 | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, | | | AND SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: SUN. JUNE 28/ 2015 | | | ACTION: BUILDING PROVISO | | | | | | A SEPARATE ROOFING PERMIT & REVIEW REQUIRED. | | | ROOFING PRODUCT APPROVAL : 13-0529.14 | | | JOHN MANVILLE MODIFIED BITUMEN OVER WOOD DECK | | | NO SUB-SYSTEM WAS IDENTIFIED, WILL NEED TO SELECT A | | | SUB-SYSTEM BETWEEN | | | PAGES 10-26. NOTE PRESSURES ARE GOOD FOR ZONE # 1 BUT | | | WILL REQUIRE | | | ENHANCED FASTENING IN ZONES 2 & 3. SEE IF LIMITATION 7 | | | OR 9 APPLIES. | | | | | | PAGE 27 LIMITATION # 7 REQUIRES RAS 117 CALCULATIONS TO | | | BE COMPLETED BY | | | EITHER AN ARCHITECT OR ENGINEER REGISTERED WITH THE | | | STATE OF FLORIDA. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-06-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-28 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-06-28 |
Time |
06:22 |
Sent To |
|
|
| Notes |
| 2015-06-28 06:42:41 | BUILDING PLAN REVIEW | | | PERMIT: 15060911 | | | ADD: 1220 ORTEGA RD | | | CONT: WILBUR HOBGOOD CONST. | | | TEL: (561)691-9686 | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, | | | AND SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: SUN. JUNE 28/ 2015 | | | ACTION: BUILDING PROVISO | | | | | | A SEPARATE ROOFING PERMIT & REVIEW REQUIRED. | | | ROOFING PRODUCT APPROVAL : 13-0529.14 | | | JOHN MANVILLE MODIFIED BITUMEN OVER WOOD DECK | | | NO SUB-SYSTEM WAS IDENTIFIED, WILL NEED TO SELECT A | | | SUB-SYSTEM BETWEEN | | | PAGES 10-26. NOTE PRESSURES ARE GOOD FOR ZONE # 1 BUT | | | WILL REQUIRE | | | ENHANCED FASTENING IN ZONES 2 & 3. SEE IF LIMITATION 7 | | | OR 9 APPLIES. | | | | | | PAGE 27 LIMITATION # 7 REQUIRES RAS 117 CALCULATIONS TO | | | BE COMPLETED BY | | | EITHER AN ARCHITECT OR ENGINEER REGISTERED WITH THE | | | STATE OF FLORIDA. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-07-23 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-23 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-07-23 |
Time |
09:43 |
Sent To |
I |
|
| Notes |
| 2015-07-23 11:18:39 | APPROVED W/PROVISO: THERE ARE A COUPLE OF ITEMS WHICH | | | ARE MISSING FROM THE DRAWINGS THAT HAVE BEEN MARKED AND | | | MENTIONED ON THE APPROVED PLANS. WHICH SHALL BE | | | ADDRESSED FOR INSPECTION. | | | 1. NEC 600.5(A) REQUIRED BRANCH CIRCUIT. EACH | | | COMMERCIAL BUILDING AND EACH COMMERCIAL OCCUPANCY | | | ACCESSIBLE TO PEDESTRIANS SHALL BE PROVIDED WITH AT | | | LEAST ONE OUTLET IN AN ACCESSIBLE LOCATION AT EACH | | | ENTRANCE TO EACH TENANT SPACE FOR SIGN OR OUTLINE | | | LIGHTING SYSTEM USE. THE OUTLET(S) SHALL BE SUPPLIED BY | | | A BRANCH CIRCUIT RATED AT LEAST 20 AMPERES THAT | | | SUPPLIES NO OTHER LOAD. SERVICE HALLWAYS OR CORRIDORS | | | SHALL NOT BE CONSIDERED ACCESSIBLE TO PEDESTRIANS. | | | 2. FBC-B 1006.3 EXITS SHALL BE MARKED BY AN APPROVED | | | SIGN READILY VISIBLE FROM ANY DIRECTION OF EXIT ACCESS. | | | EVERY EXIT SHALL BE SUITABLY ILLUMINATED BY A RELIABLE | | | LIGHT SOURCE. EXTERNALLY & INTERNALLY ILLUMINATED SIGNS | | | SHALL BE VISIBLE IN BOTH NORMAL & EMERGENCY LIGHTING. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2015-07-02 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-07-02 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-07-02 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2015-07-02 10:38:22 | SEE E12030009 FOR ENGINEERING DEVELOPMENT APPROVAL. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-08-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-08-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-08-19 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-06-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-06-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-06-23 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2015-06-23 15:34:14 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET A 1 - THERE IS AN INCORRECT REFERNECE TO THE | | | FIRE CODE. | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | 2) SHEET A 5 - THE NEW EXIT DOORS SHALL SWING IN THE | | | DIRECTION OF EGRESS. PLEASE REVIEW THE FOLLOWING: | | | NFPA 101 CHAPTER 7, MEANS OF EGRESS | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | | OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE | | | REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY, | | | OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT | | | MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A | | | CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN, | | | UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET: | | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | | EXISTING BUILDING. | | | (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS | | | PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED | | | WIDTH OF THE STAIR LANDING WHEN THE DOOR LEAF IS FULLY | | | OPEN. | | | | | | 3) NO EXIT DOOR SHALL BE LOCKED FROM THE EGRESS SIDE. | | | ANY AND ALL LOCKING MECHANISMS SHALL BE COMPLAINT WITH | | | CHAPTER 7 OF THE FLORIDA FIRE PREVENTION CODE. PROVIDE | | | A DOOR SCHEDULE INCLUDING EXIT AND LATCH HARDWARE. | | | | | | 4) SHEET E 2.01 - PROVIDE AND EXIT SIGN AT THE SIDE | | | EXIT DOOR. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-26 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-07 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-07-23 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-23 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-06-19 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2015-07-23 11:21:05 | CONTRACTOR NOTIFIED VIA EMAIL. RETURNED TO C11 DUE TO | | | PIGGYBACK PERMIT 15060916 MISSING BLDG. REVIEW. MA | | 2015-06-19 17:34:49 | PLACED IN C11 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-26 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-26 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2015-08-26 09:52:22 | JULY 22/2015 | | | MU-2015-18295 | | | 598 SQ. FT. | | | $954.34 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-06-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-28 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-06-28 |
Time |
06:34 |
Sent To |
|
|
| Notes |
| 2015-06-28 06:35:43 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-08-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-08-14 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-08-14 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-07-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-07-07 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-07-07 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2015-07-07 11:26:58 | 1ST REVIEW: FBC 2010 MECHANICAL | | | | | | 1) ENERGY COMPLIANCE FORM 506-2010: A) THE CONSTRUCTION | | | MATERIALS LISTED FOR THE LOADING DOCK WALLS IN THE | | | INPUT DATA REPORT SHOW SOLID WALLS WHICH DOES NOT MATCH | | | THE PLAN WHICH SHOWS SEVEN INSULATED ROLL-UP DOORS. B) | | | THE REPORT IS LISTING ONLY TWO MAN DOORS HOWEVER THERE | | | ARE THREE SHOWN ON THE PLAN. | | | 2) THE AIR SYSTEM SIZING SUMMARIES INDICATE THE | | | LOCATION OF THE PROJECT TO BE IN MIAMI. PLEASE REVISE | | | THE CALCS TO INDICATE WEST PALM BEACH LOCATION, AND USE | | | THE CORRECT DB/WB TEMPERATURES PER TABLE 1A MANUAL N. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-07-14 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-07-14 |
Time |
05:21 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-07-14 |
Time |
05:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-06-26 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-06-26 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-06-26 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|