| Plan Review Stops For Permit 15060822 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-10-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-09 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-09 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-09-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-09-25 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-09-25 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2015-09-25 13:56:53 | BUILDING PLAN REVIEW | | | W. P. B. SUBMITTAL: 15060822 | | | W. P. B. PERMIT: 14050111 | | | ADD: 600 OKEECHOBEE BLVD. | | | CONT: COASTAL | | | TEL: (954)610-8729/ VINVENT | | | E-MAIL: | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: FRI. SEPT. 25/2015 | | | ACTION: DENIED | | | | | | 1) SEMI-COMPLIED. ONLY (2) SETS OF DOCUMENTS WERE | | | SUBMITTED, THIS IS A THRESHOLD BUILDING WITH A SPECIAL | | | INSPECTOR (ON-SITE) WHICH WILL REQUIRE A 3RD SET OF | | | SIGNED AND SEALED DRAWINGS FOR THEIR OWN RECORDS. | | | | | | 1A) ARCHITECTURAL SHEETS A3.02 &A9.08 STILL ONLY 2 SETS | | | OF PLANS. REVISION # 14 DATED 8/12/15 ONE MORE SET OF | | | PLANS REQUIRED FOR THE THRESHOLD INSPECTOR. | | | | | | 1B) COMPLIED. NOVUM PLANS SUBMITTED 3 SETS OF PLANS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-07-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-07-10 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-07-10 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2015-07-10 08:45:28 | BUILDING PLAN REVIEW | | | W. P. B. SUBMITTAL: 15060822 | | | W. P. B. PERMIT: 14050111 | | | ADD: 600 OKEECHOBEE BLVD. | | | CONT: COASTAL | | | TEL: (954)610-8729/ VINVENT | | | E-MAIL: | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. JULY 10/2015 | | | ACTION: DENIED | | | | | | 1) ONLY (2) SETS OF DOCUMENTS WERE SUBMITTED, THIS IS A | | | THRESHOLD BUILDING WITH A SPECIAL INSPECTOR (ON-SITE) | | | WHICH WILL REQUIRE A 3RD SET OF SIGNED AND SEALED | | | DRAWINGS FOR THEIR OWN RECORDS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-09-25 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-25 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-25 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-08-10 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-08-10 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-08-10 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2015-08-10 13:33:34 | 8/10/2015 | | | PROJECT: HILTON HOTEL PORT COCHERE | | | PERMIT#: 15060822 | | | CODE: 2011 EDITION OF THE NEC, 5TH EDITION OF THE FBC, | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER ONE, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | | COMMENTS: | | | | | | 1) THERE ARE NO ELECTRICAL PLANS INCLUDED WITH THIS | | | SUBMITTAL. PROVIDE ELECTRICAL PLANS INDICATING THE | | | ELECTRICAL CIRCUITRY AND CONTROL FOR THE LED LIGHTING | | | IN THAT IS INDICATED IN THE COLUMS ON THE ORIGINAL | | | DESIGN DOCUMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-08-26 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-08-26 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-08-26 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-08-05 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-08-05 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-08-05 |
Time |
09:26 |
Sent To |
E |
|
| Notes |
| 2015-08-05 09:33:49 | 600 OKEECHOBEE BOULEVARD | | | PERMIT #15060822 | | | MASTER #14050111 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PROVIDE A PLAN VIEW DRAWING SHOWING THE EXTENT OF THE | | | PORTE COCHERE IN RELATION TO THE BUILDING STRUCTURE. | | | | | | NO ADDRESS PROVIDED ON THE PLANS. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-10-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-02 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-09-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-09-25 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-21 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-08-10 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-08-10 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-08-05 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-09-15 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-09-15 |
Time |
04:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-09-05 |
Time |
08:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-07-11 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-07-11 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-07-11 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2015-07-11 09:36:53 | 1) INDICATE THE DIAMETER OF THE DOWNSPOUTS THAT ARE | | | LOCATED IN THE COLUMNS AND SHOW THE SQUARE FOOTAGE | | | DRAINED BY EACH DOWNSPOUT. THE DOWNSPOUTS SHALL BE | | | SIZED IN ACCORDANCE WITH TABLE 1106.2 (1). | | | THE SIZING SHALL BE BASED ON A PROJECTED RAINFALL RATE | | | OF 5 INCHES PER HOUR, | | | 2) THE PLAN SHOWS THE DOWNSPOUT DISCHARGING ABOVE | | | GRADE. THE LOCARION / TERMINATION OF THE DISCHARGE | | | SHALL NOT CAUSE A NUISANCE TO PEDESTRIANS. THE | | | DOWNSPOUTS SHALL DRAIN INTO A SEPARATE STORM SEWER | | | SYSTEM OR TO AN APPROVED PLACE OF DISPOSAL. 2010 FPC | | | SEC.1101.2. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-09-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-09-14 |
Time |
14:35 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2015-09-14 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-07-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-07-27 |
Time |
15:07 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2015-07-27 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2015-07-27 15:12:54 | FAILED | | | | | | PROVIDE WRITTEN RESPONSE. | | | | | | 1) THE CANOPY ON THE ZONING APPROVED ARCHITECTURAL | | | PLANS EXTENDS APPROXIMATELY 18 FEET FROM THE SUPPORT | | | COLUMNS OVER THE DRIVE. THE SUBMITTED BUILDING PERMIT | | | ONLY SHOWS A 12.5 FOOT CANOPY EXTENSION OVER THE DRIVE. | | | PLEASE EXPLAIN THIS DISCREPANCY. | | | | | | 2) PROVIDE A CROSS SECTION SHOWING THE CANOPY AND THE | | | DRIVE AISLES, THE SIDEWALK AND THE FRONT OF THE | | | BUILDING, CLEARLY LABELED AND DIMENSIONED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|