Plan Review Details - Permit 15060809
| Plan Review Stops For Permit 15060809 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2015-11-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-30 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-30 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-06-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-20 |
Time |
02:43 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-20 |
Time |
02:15 |
Sent To |
|
|
| Notes |
| 2015-06-20 02:43:48 | 1) SUBMIT TWO COPIES OF THE MANUFACTURER'S | | | SPECIFICATIONS FOR REVIEW. ALL EQUIPMENT SHALL BE | | | LISTED AND LABELED PER THE 2010 FBC-RESIDENTIAL, SEC. | | | G2404.3, WPB AMEND. TO 2010 FBC SEC. 107.1. | | | 2) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | THAT ARE USED FOR THE SIZING OF THE GAS LINE. 2010 | | | FBC-RESIDENTIAL, SEC. G2413.3. | | | 3) ONE COPY OF THE PLANS IS DONE IN PENCIL. PLANS IN | | | PENCIL ARE UNACCEPTABLE. | | | 4) INDICATE THE PSI OF THE SYSTEM. IF IT IS A HYBRID | | | PRESSURE SYSTEM, SHOW WHERE THE PRESSURE REGULATOR IS | | | LOCATED ON THE PLAN. WPB AMEND. TO 2010 FBC SEC. | | | 107.2.1. | | | 5) SUBMIT A DETAIL OF THE VENT FOR THE APPLIANCE. SHOW | | | THE SIZE OF THE VENT. THE VENT TERMINATION LOCATION | | | SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS IF THIS IS A DDIRECT VENT APPLIANCE. | | | 6) IF YOU ARE ALSO DOING THE WATER PIPING SUBMIT A | | | WATER RISER FOR THE COLD & HOT WATER LINES AND SHOW THE | | | TYPE OF PIPE & SIZES AND THE SOURCE OF THE WATER | | | SUPPLY. INCLUDE THIS UNDER THE DESCRIPTION OF WORK ON | | | THE APPLICATION.WPB AMEND. TO 2010 FBC SEC. 107.3.5.3. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-11-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-11-30 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-11-30 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-06-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-20 |
Time |
02:44 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-18 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2015-06-18 14:08:34 | INCOMING SENT TO PLUMBING BOX <$5K. |
|
|
|