Plan Review Details - Permit 15060794
Plan Review Stops For Permit 15060794
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-07-21 Cont ID  
Sent By jwitmer Date 2015-07-21 Time 16:46 Rev Time 0.00
Received By jwitmer Date 2015-07-21 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-07-08 Cont ID  
Sent By jwitmer Date 2015-07-08 Time 07:15 Rev Time 0.00
Received By jwitmer Date 2015-06-21 Time 11:02 Sent To  
Notes
2015-06-21 11:26:59 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15060794
 ADD: 1200 S. FLAGLER DR. SUITE #1902
 CONT: GREG GIULIANO CONSTRUCTION
 TEL: (561)301-1591
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE:
 ACTION: DENIED
  
 1) SHEET A1 THE COVERSHEET INDICATES THIS A R2 HIGH
 RISE- 19 STORIES. FOR HIGHRISE WITH 19 STORIES THE
 CONSTRUCTION TYPE HAS TO BE TYPE IA NOT V-B. 2010 FBC-B
 TABLE 503.
  
  
 2) ON SHEET A1 THERE IS A FLOORING NOTE TO REMOVE THE
 EXISITNG TILE THROUGHOUT AND TO INSTALL PROFLEX SOUND
 INSULATION. PLEASE PROVIDE WHICH PRODUCT FROM PROFLEX
 IS BEING PROPOSED FOR THE INSTALATION. PROVIDE TEST
 REPORTS TO THE ASTM STANDARDS LISTED BELOW.
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION
  
 2A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 2B) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-07-21 Cont ID  
Sent By albarran Date 2015-07-21 Time 17:10 Rev Time 0.00
Received By albarran Date 2015-07-21 Time 17:04 Sent To M
Notes
2015-07-21 17:12:367/21/15 - ALL PRIOR PROVISOS HAVE BEEN INCORPORATED
 INTO GENERAL NOTES ON THE APPROVED PLANS. SENT TO
 MECHANICAL, CC. MA

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-07-16 Cont ID  
Sent By albarran Date 2015-07-16 Time 10:41 Rev Time 0.00
Received By albarran Date 2015-07-16 Time 17:04 Sent To I
Notes
2015-07-16 10:42:22ELECTRICAL PROVISO
 PERMIT #15060794
 1. GENERAL ELECTRICAL NOTES TO BE AMENDED TO INCLUDE,
 ?SMOKE DETECTORS SHALL HAVE BATTERY BACK-UP AND BE
 INTER-CONNECTED.
 2. ALL OUTLET BOXES IN A FIRE RATED WALL SHALL BE
 PROTECTED WITH LISTED FIRE-BLOCKING MATERIAL.
 3. ALL CEILING LUMINAIRE OUTLETS SHALL BE RATED TO
 SUPPORT 50LBS. PER NEC 314.27.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-07-23 Cont ID  
Sent By pleduc Date 2015-07-23 Time   Rev Time 0.00
Received By pleduc Date 2015-07-23 Time 14:17 Sent To PC
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-06-23 Cont ID  
Sent By pleduc Date 2015-06-23 Time   Rev Time 0.00
Received By pleduc Date 2015-06-23 Time 10:55 Sent To  
Notes
2015-06-23 11:04:37THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE
 FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND
 COMPLIANCE. ANY REMOVAL AND/OR CONSTRUCTION OF WALLS
 REQUIRES AN EVALUATION.
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-23 Cont ID  
Sent By pleduc Date 2015-07-23 Time   Rev Time 0.00
Received By pleduc Date 2015-07-17 Time 15:31 Sent To  
Notes
2015-07-17 15:31:37ROUTED TO JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-07-16 Cont ID  
Sent By albarran Date 2015-07-16 Time 10:42 Rev Time  
Received By albarran Date 2015-06-18 Time   Sent To  
Notes
2015-07-16 10:44:207/16/15 - PASSED ELECTRICAL REVIEW BUT FAILED BLDG.
 CONTRACTOR NOTIFIED VIA EMAIL. SENT TO SMALL DENIED BIN
 "G". MA
2015-06-18 14:45:54INCOMING SENT TO B-05 BOX.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2015-06-21 Cont ID  
Sent By jwitmer Date 2015-06-21 Time 11:04 Rev Time 0.00
Received By jwitmer Date 2015-06-21 Time 11:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2015-07-22 Cont ID  
Sent By ccole Date 2015-07-22 Time 07:36 Rev Time 0.00
Received By ccole Date 2015-07-22 Time 07:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2015-07-08 Cont ID  
Sent By ccole Date 2015-07-08 Time 09:53 Rev Time 0.00
Received By ccole Date 2015-07-08 Time 09:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-07-22 Cont ID  
Sent By tklarge Date 2015-07-22 Time 08:40 Rev Time 0.00
Received By tklarge Date 2015-07-22 Time 08:34 Sent To FIRE
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-07-16 Cont ID  
Sent By tklarge Date 2015-07-14 Time 10:44 Rev Time 0.00
Received By tklarge Date 2015-07-14 Time 09:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-06-22 Cont ID  
Sent By ajones Date 2015-06-22 Time 15:00 Rev Time 0.00
Received By ajones Date 2015-06-22 Time 15:00 Sent To  
Notes
***NONE***