Plan Review Details - Permit 15060749
| Plan Review Stops For Permit 15060749 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-10-01 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
|
Date |
2015-10-01 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-07-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-07-17 |
Time |
10:37 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2015-07-17 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2015-07-17 10:36:59 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15060749 | | | ADD: 5337 N. MILITARY TRL. | | | CONT: SOUTHEAST GENERAL CONSTRUCTION | | | TEL: (561)278-2776 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. JULY 17/2015 | | | ACTION: DENIED | | | | | | 1) SHEET EO1.01 THE LIGHT POLE DETAIL INDICATES THE | | | FOUNDATION SIZE STEEL REBAR SIZE AND SPACING, WHAT IS | | | NOT GIVEN IS THE ANCHOR BOLT FURNISHED BY THE POLE | | | MANUFACTURER. PLEASE PROVIDE THE MANUFACTURERS SPEC NOT | | | ONLY FOR THE ANCHOR BOLT SIZE & LENGTH, QUANITITY, WIND | | | DESIGN FOR POLE AND FOR THE LUMINERE. PLANS INDICATE A | | | EPA RATING OF 6.2 AT 170 MPH. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED TO DETERMINE CODE COMPLIANCE. | | | NOTE THIS IS A EXPOSURE C CATEGORY. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-07-24 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-24 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-07-24 |
Time |
08:52 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-06-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-06-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-06-22 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-01 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-09-29 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2015-09-29 15:48:43 | RESUB ROUTED TO LLOUIE VIA SGRAHAM'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-07-24 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-24 |
Time |
09:23 |
Rev Time |
|
| Received By |
albarran |
Date |
2015-06-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-07-24 09:30:51 | 7/24/15 - COMPLETED ALL REVIEWS AND READY FOR | | | RESUBMITTAL. RUNNER NOTIFIED VIA EMAIL. SENT TO SMALL | | | DENIED BIN "S". MA | | 2015-06-18 10:45:09 | C08 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-09-30 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-09-30 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-09-30 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-06-26 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2015-06-26 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2015-06-26 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2015-06-26 16:11:11 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) A MINOR PD AMENDMENT TO THE SOUTH WIND PLAZA CPD IS | | | REQUIRED. AN APPLICATION WILL NEED TO BE FILED AND | | | APPROVED WITH THE DEVELOPMENT SERVICES - PLANNING | | | DIVISION PRIOR TO BUILDING PERMIT. | | | | | | 2.) THE PLANNING DIVISION'S APPLICATION FOR A MINOR PD | | | AMENDMENT CAN BE OBTAINED BY FOLLOWING THIS LINK: HTTP: | | | //WPB.ORG/PLANNING/WP-CONTENT/UPLOADS/SITES/37/2013/02/ | | | 2015-DEVELOPMENT-APPLICATION-REVISED-05.19.20151.PDF | | | | | | CONTACT LINDA LOUIE @ (561) 822-1458 IF YOU HAVE | | | QUESTIONS. | | | |
|
|
|