Plan Review Details - Permit 15060694
Plan Review Stops For Permit 15060694
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-07-21 Cont ID  
Sent By pleduc Date 2015-07-10 Time 07:30 Rev Time 0.00
Received By jwitmer Date 2015-07-21 Time 07:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-06-21 Cont ID  
Sent By jwitmer Date 2015-06-21 Time 10:57 Rev Time 0.00
Received By jwitmer Date 2015-06-21 Time 10:28 Sent To  
Notes
2015-06-21 10:51:11 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15060694
 ADD: 622 N. FLAGLER DR. / FITNESS CENTER
 CONT: BRANCH CONSTRUCTION
 TEL: ( 561)833-6206
 E-MAIL:
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SUN.JUNE 21/ 2015
 ACTION: DENIED
  
 1) SHEET A1 DOES NOT SHOW ENOUGH DETAIL AS TO THE
 LOCATION IN THE BUILDING:
 1A) PLEASE PROVIDE THE SQ. FOOTAGE OF THE FITNESS
 CENTER AND OCCUPANT LOAD TAKEN FOR THIS AREA, THERE IS
 ONLY ONE MEANS OF EGRESS INTO AND OUT OF THIS AREA. 15
 SQ. FEET /OCCUPANT W/ NO EXERCISE EQUIPMENT, 50 SQ.
 FEET W/ EQUIPMENT FBC-B TABLE 1004.1.1.
  
 1B) IS THE FITNESS CENTER ON THE SAME FLOOR AS
 RESIDENTIAL UNITS OR IS THERE RESIDENTIAL OCCUPANCY
 BENEATH THESE UNITS? AND THE THIRD QUESTION IS IN THE
 REMODELING OF THE FITNESS CENTER THE FLOOR BEING
 REPAIRED WITH MATCHING FINISH OR IS THE FLOOR BEING
 REPLACED.
 NOTE IF THE FLOOR IS BEING REPAIRED NO ACTION IS
 REQUIRED. IF THERE IS RESIDENTIAL UNITS EITHER ON THE
 SAME FLOOR, OR THE FLOOR BENEATH AND NEW FLOOR FINISHES
 ARE BEING INSTALLED EITHER MARBLE TILE OR WOOD FLOORING
 THEN THE FOLLOWING (3) CODE SECTION SHALL APPLY;
  
 1B)(1) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B)(2) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1B)(3) FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-07-07 Cont ID  
Sent By skennedy Date 2015-07-07 Time 15:53 Rev Time 0.00
Received By skennedy Date 2015-07-07 Time 15:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-07-10 Cont ID  
Sent By pleduc Date 2015-07-09 Time   Rev Time 0.00
Received By pleduc Date 2015-07-10 Time 10:57 Sent To B
Notes
2015-07-09 13:40:44THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THERE WERE NO PLANS SUBMITTED WITH THIS APPLICATION,
 ONLY TWO SEALED LETTERS FROM THE ARCHITECT.
  
 PAPERWORK/PLANS CORRECTED, PASSED, 7/10/15.PML

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-06-22 Cont ID  
Sent By pleduc Date 2015-06-22 Time   Rev Time 0.00
Received By pleduc Date 2015-06-22 Time 14:21 Sent To  
Notes
2015-06-22 14:41:16THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) IS THE FITNESS CENTERAND EQUIPMENT EXISTING AND
 PREVIOUSLY APPROVED AND IS BEING REMODLED OR IS IT A
 NEW PROJECT. PROVIDE AN INDICATING NOTE.
  
 2) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF
 THE 5TH EDITION OF FLORIDA FIRE PREVENTION CODE
 INCLUDING THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND
 ALL OTHER APPLICABLE CODES OR STANDARDS.
 FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 13, 2010 EDITION.
 FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 72, 2010 EDITION.
 CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 241, 2009 EDITION.
 FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 10, 2010 EDITION.
 ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION.
  
 3) PROVIDE NOTE INDICATING FIRE ALARM WORK UNDER
 SEPARATE SHOP DRAWINGS.
  
 4) PROVIDE A DOOR SCHEDULE OR NOTE FOR THE INSTALL OF
 DOORS AT THE NEW LOCATIONS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-21 Cont ID  
Sent By jwitmer Date 2015-07-21 Time 07:32 Rev Time 0.00
Received By jwitmer Date 2015-07-08 Time 08:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-06-30 Cont ID  
Sent By   Date 2015-06-30 Time   Rev Time 0.00
Received By shill Date 2015-06-16 Time 12:52 Sent To  
Notes
2015-06-30 14:20:15PULLED FROM B19 AND ROUTED TO ELECTRICAL
2015-06-16 12:58:08***EXPEDITED***
 B19
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2015-06-21 Cont ID  
Sent By jwitmer Date 2015-06-21 Time 10:32 Rev Time 0.00
Received By jwitmer Date 2015-06-21 Time 10:32 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-06-22 Cont ID  
Sent By ajones Date 2015-06-22 Time 14:59 Rev Time 0.00
Received By ajones Date 2015-06-22 Time 14:59 Sent To  
Notes
***NONE***