Plan Review Details - Permit 15060682
Plan Review Stops For Permit 15060682
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-07-21 Cont ID  
Sent By jwitmer Date 2015-07-21 Time 13:50 Rev Time 0.00
Received By jwitmer Date 2015-07-21 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-06-21 Cont ID  
Sent By jwitmer Date 2015-06-21 Time 10:25 Rev Time 0.00
Received By jwitmer Date 2015-06-21 Time 10:15 Sent To  
Notes
2015-06-21 10:25:30 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15060682
 ADD: 3800 WASHINGTON RD. 3 804
 CONT: KEMKON PROPERTIES
 TEL: (561)512-7637
 E-MAIL:
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SUN. JUNE 21/ 2015
 ACTION: DENIED
  
 1) THE CONTRACTOR NEEDS TO TAKE OWNERSHIP OF THE PLANS
 WITH HIS PRINTED NAME, WRITTEN NAME AND LICENSE NUMBER.
 107.3.4.1 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE.
  
 2) THE PLANS INDICATE THE INSTALATION OF NEW TILE WITH
 APPROVED UNDERLAYMENT. PLEASE PROVIDE THE (3) REQUIRED
 TEST FOR THE PROPOSED UNDERLAYMENT. SHOW COMPLIANCE
 WITH:
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION
  
 2A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 2B) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-07-10 Cont ID  
Sent By pleduc Date 2015-07-10 Time   Rev Time 0.00
Received By pleduc Date 2015-07-10 Time 11:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-06-22 Cont ID  
Sent By pleduc Date 2015-06-22 Time   Rev Time 0.00
Received By pleduc Date 2015-06-22 Time 14:44 Sent To  
Notes
2015-06-22 14:48:00THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) ADDRESS BUILDING DEPT. COMMENTS
  
 2) PROVIDE NOTE INDICATING THE EXISTING FIRE SPRINKLER
 OR FIRE ALARM SYSTEM AND THAT ANY SUCH SYSTEM SHALL BE
 MAINTAINED AND ACTIVE THROUGHOUT THE CONSTRUCTION
 PERIOD. ANY WORK ON ANY LIFE SAFETY SYSTEM SHALL BE
 DONE BY CERTIFIED LIFE SAFETY CONTRACTORS UNDER
 SEPARATE SHOP DRWAINGS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-21 Cont ID  
Sent By jwitmer Date 2015-07-21 Time 13:50 Rev Time 0.00
Received By jwitmer Date 2015-07-09 Time 12:47 Sent To  
Notes
2015-07-09 12:47:51ROUTED TO FIRE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-07-01 Cont ID  
Sent By tklarge Date 2015-07-01 Time 06:52 Rev Time 0.00
Received By tklarge Date 2015-06-16 Time 13:12 Sent To  
Notes
2015-06-16 13:12:10***EXPEDITED***
 B32
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-07-01 Cont ID  
Sent By tklarge Date 2015-07-01 Time 06:51 Rev Time 0.00
Received By tklarge Date 2015-07-01 Time 06:40 Sent To  
Notes
***NONE***