Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-07-27 Cont ID  
Sent By shill Date 2015-07-27 Time 18:00 Rev Time 0.00
Received By shill Date 2015-07-27 Time 18:00 Sent To  
Notes
2015-07-27 18:04:35PROVISO - SEE PERMIT 14030096, SHEET A2.1.1, ALL GATES
 TO SWING AWAY FROM THE POOL
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-07-21 Cont ID  
Sent By albarran Date 2015-07-21 Time 10:04 Rev Time 0.00
Received By albarran Date 2015-07-21 Time 08:39 Sent To B
Notes
2015-07-21 10:04:00CORRECTED THE LOAD CALCS TO MATCH SHEET SP1.03

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2015-07-14 Cont ID  
Sent By mgonzale Date 2015-07-14 Time 10:48 Rev Time 0.00
Received By mgonzale Date 2015-07-14 Time   Sent To  
Notes
2015-07-14 10:49:00PROVISO/CONDITION:
  
 DISCHARGE OF THE SHOWER WOULD BE ALLOWED IF A CURB IS
 PLACED AROUND THE SHOWER FLOOR AREA OR SLOPED WHERE
 CHLORINATED POOL WATER MAY NOT ENTER. ALSO DRAIN WOULD
 HAVE DISPLAY A SIGN POSTED THAT THE DRAIN DRAINS TO THE
 LAKE WORTH LAGOON (INTERCOASTAL WATERWAY), NO DUMPING
 OR USE OF CONTAMINANTS, SOAPS, ETC.
  
 DECHLORINATED SWIMMING POOL DISCHARGES ARE AUTHORIZED
 IN FLORIDA IN ACCORDANCE WITH 62-624.200(2)(Q), F.A.C.;
 PROVIDED THAT THEY DO NOT CAUSE A VIOLATION OF WATER
 QUALITY STANDARDS."
 SUBSECTION 62-302.530(19), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.) LIMITS THE DISCHARGE OF CHLORINE TO SURFACE
 WATER BODIES TO < 0.01 MILLIGRAM PER LITER (MG/L).
 IN ADDITION, TURBIDITY ASSOCIATED WITH BACKWASHING AND
 CLEANING CAN ALSO VIOLATE SURFACE WATER QUALITY
 STANDARDS THEREFORE POOL DISCHARGES MUST BE CONTROLLED
 AND PROGRAMMED.
 FOR REFERENCE PLEASE KNOW THAT THE FLORIDA DEPARTMENT
 OF HEALTH REGULATES PUBLIC SWIMMING POOLS AND BATHING
 PLACES. SUBSECTION 64E-9.007 (15) ?POOL WASTE WATER
 DISPOSAL? STATES IN PART: ?POOL WASTE WATER SHALL BE
 DISCHARGED THROUGH AN AIR GAP; DISPOSAL SHALL BE TO
 SANITARY SEWERS, STORM SEWERS, DRAINFIELDS, OR BY OTHER
 MEANS, IN ACCORDANCE WITH LOCAL MUNICIPAL AND BUILDING
 OFFICIAL REQUIREMENTS INCLUDING OBTAINING ALL NECESSARY
 PERMITS.?
  
 GUIDANCE:
 TO HELP PROTECT FLORIDA?S ENVIRONMENT, THE FOLLOWING
 BEST MANAGEMENT PRACTICES SHOULD BE FOLLOWED WHEN
 DRAINING SWIMMING POOLS OR DISCHARGING FILTER BACKWASH
 INTO THE ENVIRONMENT.
 ONLY DRAIN YOUR POOL WHEN NECESSARY. AVOID
 DRAINING/BACKWASHING YOUR POOL DURING PERIODS OF
 DROUGHT AND DURING SIGNIFICANT RAINFALL EVENTS. DO NOT
 DRAIN YOUR POOL WHEN WATERING RESTRICTIONS ARE IN
 PLACE.
 BEFORE DRAINING YOUR POOL, ALLOW THE WATER TO STAND FOR
 AT LEAST 48 HOURS AFTER THE LAST ADDITION OF CHLORINE
 OR UNTIL THE FREE CHLORINE RESIDUAL IS < 0.01 MG/L. (IF
 YOU NEED TO DRAIN YOUR POOL QUICKLY, YOU CAN PURCHASE
 CHLORINE-NEUTRALIZING CHEMICALS SUCH AS SODIUM
 THIOSULFATE AT YOUR LOCAL POOL SUPPLY COMPANY.)
 TEST THE FREE CHLORINE RESIDUAL BEFORE DISCHARGING. A
 FREE CHLORINE RESIDUAL SHOULD NOT BE DETECTED. THE
 CHLORINE RESIDUAL CAN BE TESTED USING A STANDARD POOL
 TEST KIT. (REFER TO 64E-9.004 (11), F.A.C. FOR
 ADDITIONAL INFORMATION.)
 THE WATER SHOULD BE CLEAR AND FREE OF SOLIDS.
 THE PH MUST BE BETWEEN 6.5 AND 8.5 BEFORE IT IS
 DISCHARGED.
 ALGAECIDES CONTAINING COPPER OR SILVER CAN INTERRUPT
 NORMAL ALGAL AND PLANT GROWTH IN SURFACE WATER BODIES
 AND SHOULD BE USED WITH CAUTION. FOLLOW THE
 MANUFACTURER?S INSTRUCTIONS BEFORE DISCHARGING WATER
 THAT HAS HAD AN ALGAECIDE ADDED RECENTLY.
 CONTROL THE RATE OF DISCHARGE ACROSS YOUR PROPERTY TO
 AVOID EROSION AND NUISANCE CONDITIONS FOR NEIGHBORING
 PROPERTIES. NUISANCE CONDITIONS SUCH AS THE CREATION OF
 ODORS, MOSQUITO BREEDING CONDITIONS, OR FLOODING CAN
 OCCUR WHEN WATER IS PONDED FOR A PROLONGED PERIOD.
 DIRECT THE DISCHARGE OVER A VEGETATED SURFACE SO THAT
 SOME LEVEL OF FILTRATION CAN OCCUR.
 DO NOT DISCHARGE ON AREAS RECENTLY TREATED WITH
 HERBICIDES OR PESTICIDES.
  
 GUIDANCE IF DISPOSING TO CITY SANITARY SEWER SYSTEM:
 POOL AND SPA WASTEWATER SHOULD NOT BE DISCHARGED INTO
 THE SANITARY SEWER SYSTEM WITHOUT THE PERMISSION OF THE
 WASTEWATER TREATMENT FACILITY.
 AVOID DISCHARGING TO THE SANITARY SEWER SYSTEM DURING
 OR IMMEDIATELY AFTER A SIGNIFICANT RAINFALL EVENT."
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2015-06-27 Cont ID  
Sent By tklarge Date 2015-06-27 Time 03:12 Rev Time 0.00
Received By tklarge Date 2015-06-27 Time 03:12 Sent To  
Notes
2015-06-27 03:14:21GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS AND GAS RISER THAT REFLECTS THE
 ENTIRE SCOPE OF GAS WORK TO BE DONE UNDER A SEPARATE
 GAS PERMIT. WPB AMEND. TO FBC SEC. 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-07-27 Cont ID  
Sent By shill Date 2015-07-27 Time 18:03 Rev Time 0.00
Received By shill Date 2015-06-16 Time 13:01 Sent To  
Notes
2015-06-23 13:14:30TO POOL BOX.
2015-06-16 13:01:45TO ZONING
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-07-09 Cont ID  
Sent By tklarge Date 2015-07-09 Time 03:12 Rev Time 0.00
Received By tklarge Date 2015-06-24 Time 06:26 Sent To  
Notes
2015-06-27 03:11:33PASSED W/ PROVISOS FROM M. GONZALEZ IN ENGINEERING.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-06-23 Cont ID  
Sent By aaponte Date 2015-06-23 Time 13:13 Rev Time 0.00
Received By aaponte Date 2015-06-23 Time 13:13 Sent To  
Notes
***NONE***