| Plan Review Stops For Permit 15060652 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-01 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-01 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-31 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-31 |
Time |
10:13 |
Sent To |
FIRE |
|
| Notes |
| 2015-08-31 11:12:26 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT:15060652 | | | ADD: 222 LAKEVIEW AVENUE/ GROUND FLOOR | | | CONT: HOLT LEE | | | TEL: ( 954)725-4881 | | | E-MAIL: | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: MON. AUGUST 31/ 2015 | | | ACTION: DENIED | | | | | | 1) NEW COMMENT: THE PLAN REVIEW RE-SUBMITTAL SHEET | | | INDICATES A CHANGE OF CONTRACTOR WITH CREF ESPERANTE AS | | | THE CONTRACTOR WHERE AS THE CONTRACTOR ON THE PERMIT | | | APPLICATION IS HOLT LEE. FOR A CHANGE OF CONTRACTOR A | | | NEW APPLICATION WITH THE NEW QUALIFIER TO BE SIGNED ON. | | | FLORIDA STATUTE 489. | | | | | | 2) THE SHEET A1.2 HAS BEEN UPDATED TO SHOW A MERCANTILE | | | OCCUPANCY TO THE LEFT OF THE COMMON AREA RESTROOMS AND | | | A ASSEMBLY OCCUPANCY TO THE RIGHT OF THE COMMON | | | RESTROOMS. THE DOOR SWINGS ARE CORRECT FOR THE OCCUPANT | | | LOADS. WHAT IS THE CONCERN IS THE DOOR LEADING BETWEEN | | | THE MERCANTILE OCCUPANCY AND THE COMMON RESTROOMS SHOWS | | | A EXIT LIGHT ON THE RESTROOM SIDE OF THE DOOR. THE 2010 | | | FBC-B SECTION 1014.2 EGRESS THROUGH INTERVENING SPACES. | | | EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH | | | THIS SECTION. 1014.2.1. EGRESS FROM A ROOM OR SPACE | | | SHALL NOT PASS THROUGH ADJOINING OR INTERVENING ROOMS | | | OR AREAS, EXCEPT WHERE SUCH ADJOINING ROOMS OR AREAS | | | AND THE AREA SERVED ARE ACCESSORY TO ONE OR THE OTHER, | | | ARE NOT A GROUP H OCCUPANCY AND PROVIDE A DISCERNIBLE | | | PATH OF EGRESS TRAVEL TO AN EXIT. | | | | | | WITH THE CONFIGURATION AS SHOWN THE MERCANTILE MAY BE | | | CLOSED BUT WITH THE EXIT LIGHT AS SHOWN OCCUPANTS FROM | | | THE ASSEMBLY OCCUPANCY WOULD BELIEVE THIS IS A EXIT | | | THEY COULD USE AND IF THE MERCANTILE OCCUPANCY WERE | | | CLOSED AND THE DOOR LOCKED, THERE COULD WELL BE A | | | PANIC. | | | AN EXIT ACCESS SHALL NOT PASS THROUGH A ROOM THAT CAN | | | BE LOCKED TO PREVENT EGRESS. | | | | | | 3) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED | | | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-06-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-24 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-06-24 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2015-06-24 15:28:15 | | | | BUILDING PLAN REVIEW | | | W. P. B. PERMIT:15060652 | | | ADD: 222 LAKEVIEW AVENUE/ GROUND FLOOR | | | CONT: HOLT LEE | | | TEL: ( 954)725-4881 | | | E-MAIL: | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. JUNE 24/ 2015 | | | ACTION: DENIED | | | | | | 1) THE PLANS ARE DENIED, THE SMALL AREA OF DETAIL (AREA | | | OF WORK) PROVIDED ON THE COVERSHEET AND SHEET A1.1 DOES | | | NOT LINE UP WITH GIVEN POINTS AS STAIRWELLS AND | | | ELEVATOR SHAFTS. A THOROUGH REVIEW CANNOT BE MADE AT | | | THIS TIME, AS A RESULT OF THE ADDITIONAL INFORMATION | | | REQUESTED ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT | | | PART OF THIS REVIEW. | | | | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | | TECHNICAL CODES. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-01 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-01 |
Time |
15:52 |
Sent To |
I |
|
| Notes |
| 2015-10-01 16:04:39 | 10/1/15 APPROVED WITH EXCEPTIONS AS MENTIONED BELOW: | | | FAILURE TO CORRECT THESE ISSUES PRIOR TO INSPECTION | | | WILL RESULT IN FAILED INSPECTION AND ASSESSMENT OF | | | REINSPECTION FEES. | | | 1. ELECTRIC WATER COOLER SHALL BE ON A GFI PROTECTED | | | CIRCUIT PER NEC 422.52 | | | 2. THE OTHER END OF THE CORRIDOR MAY REQUIRE AN EXIT | | | LIGHT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-06-17 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-06-17 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-06-17 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2015-06-17 14:27:00 | APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN APPROVED | | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | | DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED | | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | | FEE(S). | | | | | | 1) ELECTRIC DRINKING FOUNTAINS SHALL BE PROTECTED WITH | | | GROUND FAULT CIRCUIT INTERRUPTER PROTECTION. NEC 422.52 | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2015-09-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-09-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-09-02 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2015-08-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-08-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-08-21 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2015-08-21 12:02:44 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THIS SUBMITTAL ONLY CONTAINED TWO - 1 SHEET DRAWINGS | | | AND DID NOT ADDRESS THE NOTED CONCERNS ON THE 1ST | | | SUBMITTAL. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-06-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-06-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-06-23 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2015-06-23 10:06:59 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET A1.1 ON THE A1 DEMOLITION PLAN INDICATES A | | | DOOR BEING REMOVED. PLEASE PROVIDE THE OCCUPANCY OF THE | | | SPACE THAT THE DOOR LEADS TO AND A NOTE JUSTIFYING THAT | | | THIS DOOR IS NOT REQUIRED FOR THAT SPACE. | | | | | | 2) SHEET A1.1 ON THE ON THE A1 DEMOLITION PLAN | | | INDICATES A DOUBLE DOOR BEING REMOVED; G8 FLOOR PALN | | | INDICATES A NEW SINGLE DOOR BEING INSTALLED. PLEASE | | | PROVIDE THE OCCUPANY AND OCCUPANCY LOAD OF THE SPACE | | | THAT THIS DOOR LEADS TO. | | | | | | 3) PROVIDE COMPLETE LIFE SAFETY PLANS FOR EACH | | | OCCUPANCY THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON REVIEW OF THE | | | ABOVE RESUBMITTAL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-01 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-01 |
Time |
12:54 |
Sent To |
B |
|
| Notes |
| 2015-10-01 16:10:21 | 10/1/15 PASSED REVIEWS. CONTRACTOR NOTIFIED VIA EMAIL. | | | SENT TO LARGE READY BIN "H". MA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-09-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-09-02 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-08-28 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2015-08-28 12:48:32 | JWITMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-08-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-08-21 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-08-19 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2015-08-19 13:10:53 | ROUTED TO FIRE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-07-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-07-16 |
Time |
11:33 |
Rev Time |
|
| Received By |
tklarge |
Date |
2015-06-15 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2015-06-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-24 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-06-24 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-01 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-01 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2015-07-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-07-09 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-07-09 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-01 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-01 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-07-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-07-16 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-07-16 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2015-07-14 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2015-07-14 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2015-07-14 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|