Plan Review Details - Permit 15060554
| Plan Review Stops For Permit 15060554 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-03-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-25 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-25 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2016-03-25 12:41:32 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15060554 WASTE GAS BURNER | | | ADD: 4395 EASLEY ST. | | | CONT: TBD/ TO BE DETERMINED | | | CONTACT: KURT PFEFFER, P. E. | | | TEL: (561)997-8070 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 3RD REVIEW | | | DATE: FRI. MARCH 25/ 2016 | | | ACTION: BUILDING PROVISO | | | | | | 1) SHEET 0298 M-ADF-39 WHEN MEASURED SCALES ABOUT 12.4 | | | FEET ABOVE THE FLANGE #150. PLEASE PROVIDE ADDITIONAL | | | INFORMATION IF THE SCHEDULE 5S SST PIPE WILL REQUIRE | | | LATERAL RESISTING SYSTEM FOR THE HEIGHT OF THE PIPE AS | | | WELL FOR THE WIND DESIGN OF 180 MPH. | | | | | | LATERAL FORCE-RESISTING SYSTEM 2010 FBC-B 1604.4 | | | ANALYSIS. LOAD EFFECTS ON STRUCTURAL MEMBERS AND THEIR | | | CONNECTIONS SHALL BE DETERMINED BY METHODS OF | | | STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT EQUILIBRIUM, | | | GENERAL STABILITY, GEOMETRIC COMPATIBILITY AND BOTH | | | SHORT- AND LONG-TERM MATERIAL PROPERTIES. EVERY | | | STRUCTURE SHALL BE DESIGNED TO RESIST THE OVERTURNING | | | EFFECTS CAUSED BY THE LATERAL FORCES SPECIFIED IN THIS | | | CHAPTER. SEE SECTION 1609 FOR WIND LOADS? | | | | | | THE DESIGNER OF RECORD IN THE COMMENT RESPONSE DOES | | | PROVIDE THE WIND DESIGN CRITERIA AND THE GAS BURNER | | | MANUFACTURER WILL BE SUBMITTING CALCULATIONS WITH SHOP | | | DRAWINGS DEMONSTRTING COMPLIANCE WITH THE REQUIRED 180 | | | VULT WIND LOADS. | | | | | | BEFORE SHOP DRAWINGS ARE TO BE SUBMITTED THE ENGINEER | | | OF RECORD FOR REVIEW AND APPROVAL BEFORE BEING | | | SUBMITTED TO THE BUILDING DEPARTMENT. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-01-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-01-15 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-01-12 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2016-01-15 06:49:31 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15060554 WASTE GAS BURNER | | | ADD: 4395 EASLEY ST. | | | CONT: TBD/ TO BE DETERMINED | | | CONTACT: KURT PFEFFER, P. E. | | | TEL: (561)997-8070 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2ND REVIEW | | | DATE: FRI. JAN. 15/ 2016 | | | ACTION: DENIED | | | | | | 1) SHEET 0298-S-ADF-32 SHOWS A ELEVATION OF THE WASTE | | | GAS BURNER. BOTH DETAILS A & B SHOW THE WASTE GAS | | | BURNER PIPE CUT OFF AND THE TOTAL HEIGHT OF | | | THE BURNER IS NOT PROVIDED. SHEET 0298 M-ADF-39 WHEN | | | MEASURED SCALES ABOUT 12.4 FEET ABOVE THE FLANGE #150. | | | PLEASE PROVIDE ADDITIONAL INFORMATION IF THE SCHEDULE | | | 5S SST PIPE WILL REQUIRE LATERAL RESISTING SYSTEM FOR | | | THE HEIGHT OF THE PIPE AS WELL FOR THE WIND DESIGN OF | | | 180 MPH. | | | | | | LATERAL FORCE-RESISTING SYSTEM 2010 FBC-B 1604.4 | | | ANALYSIS. LOAD EFFECTS ON STRUCTURAL MEMBERS AND THEIR | | | CONNECTIONS SHALL BE DETERMINED BY METHODS OF | | | STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT EQUILIBRIUM, | | | GENERAL STABILITY, GEOMETRIC COMPATIBILITY AND BOTH | | | SHORT- AND LONG-TERM MATERIAL PROPERTIES. EVERY | | | STRUCTURE SHALL BE DESIGNED TO RESIST THE OVERTURNING | | | EFFECTS CAUSED BY THE LATERAL FORCES SPECIFIED IN THIS | | | CHAPTER. SEE SECTION 1609 FOR WIND LOADS? | | | | | | 2) 2010 FBC-B 1603.1.4 WIND DESIGN DATA. THE FOLLOWING | | | INFORMATION RELATED TO WIND LOADS SHALL BE SHOWN, | | | REGARDLESS OF WHETHER WIND LOADS GOVERN THE DESIGN OF | | | THE LATERAL FORCE-RESISTING SYSTEM OF THE STRUCTURE: | | | | | | 2.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | | | | 2.2. RISK CATEGORY. | | | | | | 2.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | | | | 2.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 2.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-07-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-07-27 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-07-27 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2015-07-27 09:17:23 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15060554 WASTE GAS BURNER | | | ADD: 4395 EASLEY ST. | | | CONT: TBD/ TO BE DETERMINED | | | CONTACT: KURT PFEFFER, P. E. | | | TEL: (561)997-8070 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: MON. JULY 27/ 2015 | | | ACTION: DENIED | | | | | | NOTE: SPECIFICATION BOOKS WILL NOT BE REVIEWED AS PART | | | OF ANY PLAN REVIEW IF SUBMITTED THEY GET STAMPED VOID. | | | | | | 1) PLEASE EITHER REMOVE THE INDEX SHEETS 0002-6-GEN.02 | | | THROUGH 0005-6-GEN.05 OR VOID THEM OUT THEY ARE OF NO | | | USE TO THIS PROJECT THE WAY IT WAS SUBMITTED. THE PLANS | | | DO NOT FOLLOW THE INDEX BEING BROUGHT IN BY BUILDING | | | TYPES. 107.2.1.4 QUALITY OF BUILDING PLANS. | | | | | | 2) SHEET 0241-S GEN-01 GENERAL STRUCTURAL NOTES, NOTE | | | G-3 PLEASE NOTE CORRECT PALM BEACH COUNTY AMENDMENTS, | | | THE CITY OF WEST PALM BEACH IS UNDER HOME RULE AND THE | | | CITY HAS ITS OWN CHAPTER 1 AMENDMENTS. 2010 WEST PALM | | | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER | | | 1, ADMINISTRATION. | | | | | | 3A) THIS PERMIT WILL REQUIRE A RESIDENT INSPECTOR. | | | PLEASE REVIEW 2010 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, SECTION 2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER INSPECTIONS | | | SERVICES. THE BUILDING OFFICIAL MAY MAKE, OR CAUSE TO | | | BE MADE BY OTHERS, THE INSPECTIONS REQUIRED BY SECTION | | | 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS OF | | | RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER | | | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR | | | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED | | | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT | | | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING | | | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. | | | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY | | | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: | | | | | | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS | | | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F ?C) IN EXCESS OF 3000 | | | POUNDS PER SQUARE INCH | | | 4. FOR PILE DRIVING | | | 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE | | | FOOT | | | 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT | | | 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | | METHODS OF CONSTRUCTION | | | | | | 3B) RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL | | | PARTIES NOTARIZED AND RETURNED TO THE BUILDING | | | DEPARTMENT. | | | FORMS E-MAILED TO: [email protected] THURS. | | | JULY 02/2015 07:25 AM. | | | | | | 3C) FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | CONTACT KEN CONRAD | | | TEL: 561-805-6666 | | | E-MAIL: [email protected] OR [email protected] | | | | | | 3D) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | | HISTORY FOR THIS TYPE OF CONSTRUCTION. THIS MAY BE | | | SUBMITTED TO KEN CONRAD BY E-MAIL. KEN CONRAD: | | | [email protected] OR [email protected] | | | | | | 3E) INFORMATIONAL!!!! NOTE FOR PAPER PLANS 3 SETS OF | | | DOCUMENTS ARE REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT | | | ISSUANCE, THE PERMIT LIBRARIAN WILL E-MAIL YOU, THE | | | APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR | | | PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN | | | COLOR, (1) FOR THE RESIDENT INSPECTOR, THE OTHER FOR | | | THE MEP INSPECTORS. | | | | | | 3F) INFORMATIONAL!!!!! PLEASE CALL THE CITY OF WEST | | | PALM BEACHES AUTOMATED TELEPHONE INSPECTIONS LINE (561) | | | 805-6700) FOR IN-PROGRESS INSPECTIONS FOR AUDITING OF | | | JOBSITE INSPECTIONS. NOTE IF INSPECTIONS ARE NOT CALLED | | | IN, THE PERMIT EXPIRES 6 MONTHS AFTER THE PERMIT | | | ISSUANCE DATE. A RENEWAL PERMIT WOULD BE REQUIRED AT | | | THAT POINT. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-02-26 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2016-02-26 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2016-02-26 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2015-12-07 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2015-12-07 |
Time |
13:05 |
Sent To |
I |
|
| Notes |
| 2015-12-07 13:33:14 | PAGE (FILE) 0479-E-GEN-02.PDF - CONNECTED LOAD AND | | | DEMAND LOAD APPEAR TO EXCEED BUS RATING AND 80% OF | | | DEMAND (CONTINUOUS) LOAD. PLEASE EXPLAIN | | | BUS IS RATED 2000A. CONNECTED LOAD IS 3100 AND DEMAND | | | LOAD LOAD IS 1700, GREATER THAN 80%. IS BUS RATED FOR | | | CONTINUOUS DUTY? | | | IDENTIFY ZONES THAT WILL NEED TO BE DELINEATED FOR | | | HAZARDOUS (ELECTRICAL) ZONE OR CLASS AND DIVISION WITH | | | THE SPECIFIC HAZARD (METHANE, CHLORINE, ETC.) |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2015-07-24 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-07-24 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-07-24 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2015-07-24 09:52:22 | JOHN ROACH VERIFIED APPLICATION WAS CONSISTENT WITH | | | APPROVED SITE PLAN. SITE PLAN APPROVAL LETTER NOT YET | | | DRAFTED. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2015-06-30 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-06-30 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-06-30 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2015-06-30 08:35:44 | FOR WASTE GASE BURNERS | | | | | | 1. PLEASE SUBMIT A COPY OF THE APPROVED SITE PLAN | | | (Z14080026). WHEN SITE PLAN REVIEW IS REQUIRED, REVIEW | | | AND APPROVAL ARE NECESSARY PRIOR TO ISSUANCE OF A | | | BUILDING PERMIT. [SECTION 94-35(G) OF THE CITY'S CODE | | | OF ORDINANCES] | | | | | | KELLY CRANFORD, P.E. | | | LAND DEVELOPMENT ENGINEER | | | PUBLIC WORKS DEPARTMENT | | | CITY OF WEST PALM BEACH | | | [email protected] | | | 561-494-1098 (OFFICE) |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-06-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-06-25 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-06-25 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2016-01-15 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-01-15 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-01-15 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2016-01-15 09:50:11 | PASSED WITH PROVISOS | | | | | | GAS PROVISOS - | | | GAS PERMIT APPLICATION REQUIREMENTS | | | | | | EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL | | | BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING | | | IN THE CITY OF WEST PALM BEACH: | | | | | | 1.) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2014 FBC-FUEL | | | GAS, SECS. 402.4.1, 402.4.2. OR 2014 FBC-RES SEC. | | | G2413. | | | | | | 2.) SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING FOR EACH PIPE SIZE. | | | WPB AMENDMENTS TO FBC SEC.107.2.1. | | | | | | 3.) TYPE OF GAS (LP OR NATURAL). | | | | | | 4.)TU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE 2014 FBC-FUEL GAS SECS.401.8 | | | THRU 402.6.1 AND TABLES 402.4 (1) THRU 402.4 (37) OR | | | 2014 FBC-RES. SEC. G2413. | | | | | | 5.) SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER OR MP REGULATOR) TO THE MOST REMOTE OUTLET IN | | | THE BUILDING AND / OR SYSTEM PER THE 2014 FBC-FUEL GAS | | | SEC.402.4.1 OR 2014 FBC-RES. SEC. G 2413.3. | | | | | | 6.) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2014 | | | FBC-FUEL GAS CODE SEC.304.1 OR 2014 FBC-RES. SEC. G | | | 2407. | | | | | | 7.) INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2014 FBC-FUEL GAS SEC.402.2 OR FBC RES. | | | SEC. G2413.2. . | | | | | | 8.) SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE | | | AND TERMINATION OF THE GAS VENTS PER 2014 FBC-FUEL GAS | | | SECS. 502 THRU 505. OR 2014 FBC-RES. SEC.G2426. | | | | | | 9) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2014 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2014 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. | | | | | | 10.) CLEARLY SHOW THE LOCATION AND CAPACITY OF LP | | | TANK(S), TYPE OF TANK ( DOT OR ASME ), THE DISTANCE OF | | | THE TANK FROM THE EXTERIOR BUILDING WALL AND ADJACENT | | | PROPERTY LINES, THE DISTANCE OF THE TANK FROM ALL | | | SOURCES OF IGNITION, OTHER CONTAINERS, BUILDINGS, AND | | | THE LOCATION OF ANY BUILDING OPENINGS BELOW THE RELIEF | | | VALVE OF THE TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | 11.) CLEARLY INDICATE ON THE PLAN IF THE LP TANK IS | | | ABOVE GROUND OR BELOW GROUND, AND SHOW THE METHOD OF | | | REQUIRED PROTECTION FOR THE LP TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK IS BELOW GROUND IT SHALL BE | | | ANCHORED PER NFPA 58 SEC.3-2.2.7 (H). IF ABOVE GROUND, | | | THE TANK SHALL BE SECURELY ANCHORED TO WITHSTAND 170 | | | MPH ULT WIND LOAD PER THE FLORIDA BUILDING CODE. | | | | | | ANY QUESTIONS REGARDING THESE REQUIREMENTS MAY BE | | | REFERRED TO THE CHIEF PLUMBING INSPECTOR AT | | | 561-805-6692. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-03-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-25 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-21 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-02-26 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2016-02-26 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2016-01-06 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-12-07 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-06-17 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2015-07-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-07-27 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-07-27 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-01-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-01-14 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-14 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2016-01-14 17:14:47 | MECHANICAL PROVISOS: | | | PERMIT #15060554 | | | 01/14/1 | | | 1) SHOP DRAWINGS AND WIND LOAD TIE DOWN ENGINEERING FOR | | | THE WASTE GAS BURNER AND ASSOCIATED PIPING AND | | | EQUIPMENT SHALL BE REVIEWED AND APPROVED BY THE EOR AND | | | SUBMITTED TO THE BUILDING DEPARTRMENT PRIOR TO 1ST | | | INSPECTION. | | | A) DEFERRED SUBMITTAL: 107.3.4.2 DEFERRED SUBMITTALS. | | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | | NOT SUBMITTED AT THE TIME OF THE | | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | | REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | B) DEFERRED SUBMITTAL. 2010 FBC 107.3.4.1 PRODUCT | | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-08-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-08-04 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-08-04 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2015-08-04 11:11:25 | 1ST REVIEW: FBC 2010 MECHANICAL | | | PERMIT #15060554 WASTE GAS BURNERS | | | 8/3/15 | | | | | | 1) REFER TO SECTION 301.12 FBC-10 MECHANICAL: THE WASTE | | | GAS BURNER AND ALL OTHER ASSOCIATED EQUIPMENT SHALL BE | | | DESIGNED AND INSTALLED TO WITHSTAND 170 MPH WIND LOADS | | | AS OUTLINED IN SECTION 1609 FBC-10 BUILDING. PLEASE | | | PROVIDE THE WINDLOAD DESIGN CRITERIA ON THE PLAN AND | | | INSTALLATIOMN DETAILS AND NOTES TO SHOW COMPLIANCE. | | | 2) SHEET M-STD-03 (INCLUSIVE OF ALL PERMIT PLAN SETS | | | CONTAINING THIS SHEET): REVISE NOTES #10 & 13 | | | REFERENCING THE CITY OF TALLAHASSEE FIRE HYDRANT | | | COMPLIANCE INFORMATION. | | | 3) BASED ON THE SOILS REPORT- PIPE BEDDING AND | | | DEWATERING GUIDELINES, PLEASE PROVIDE PIPE TRENCH | | | CROSS-SECTION DETAILS FOR TYPICAL INSTALLATIONS AND | | | HIGH WATER TABLE INSTALLATIONS. INDICATE TRENCH | | | DIMENSIONS, PIPE EMBEDMENT DEPTHS, BEDDING MATERIALS | | | AND THICKNESSES, COMPACTION AND BACKFILLING | | | SPECIFICATIONS. | | | 4) PROVIDE CIVIL DRAWINGS THAT INCLUDE OVERALL | | | UNDERGROUND PIPING LAYOUTS, AND ENLARGED AREA DRAWINGS | | | DEPICTING THE UNDERGROUND PIPINGS SPECIFICALLY | | | SERVICING EACH TANK, FACILITY, BUILDING, ETC. | | | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR PIPINGS AND | | | FITTINGS REVIEWED AND APPROVED BY THE DESIGN | | | PROFESSIONAL OF RECORD. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-01-15 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-01-15 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-01-15 |
Time |
06:38 |
Sent To |
|
|
| Notes |
| 2016-01-15 09:47:05 | GAS PROVISOS - | | | GAS PERMIT APPLICATION REQUIREMENTS | | | | | | EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL | | | BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING | | | IN THE CITY OF WEST PALM BEACH: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2014 FBC-FUEL | | | GAS, SECS. 402.4.1, 402.4.2. OR 2014 FBC-RES SEC. | | | G2413. | | | | | | 2. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING FOR EACH PIPE SIZE. | | | WPB AMENDMENTS TO FBC SEC.107.2.1. | | | | | | 3. TYPE OF GAS (LP OR NATURAL). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE 2014 FBC-FUEL GAS SECS.401.8 | | | THRU 402.6.1 AND TABLES 402.4 (1) THRU 402.4 (37) OR | | | 2014 FBC-RES. SEC. G2413. | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (METER | | | OR MP REGULATOR) TO THE MOST REMOTE OUTLET IN THE | | | BUILDING AND / OR SYSTEM PER THE 2014 FBC-FUEL GAS | | | SEC.402.4.1 OR 2014 FBC-RES. SEC. G 2413.3. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2014 | | | FBC-FUEL GAS CODE SEC.304.1 OR 2014 FBC-RES. SEC. G | | | 2407. | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2014 FBC-FUEL GAS SEC.402.2 OR FBC RES. | | | SEC. G2413.2. . | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER 2014 FBC-FUEL GAS | | | SECS. 502 THRU 505. OR 2014 FBC-RES. SEC.G2426. | | | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2014 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2014 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. | | | | | | 10. CLEARLY SHOW THE LOCATION AND CAPACITY OF LP | | | TANK(S), TYPE OF TANK ( DOT OR ASME ), THE DISTANCE OF | | | THE TANK FROM THE EXTERIOR BUILDING WALL AND ADJACENT | | | PROPERTY LINES, THE DISTANCE OF THE TANK FROM ALL | | | SOURCES OF IGNITION, OTHER CONTAINERS, BUILDINGS, AND | | | THE LOCATION OF ANY BUILDING OPENINGS BELOW THE RELIEF | | | VALVE OF THE TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | 11. CLEARLY INDICATE ON THE PLAN IF THE LP TANK IS | | | ABOVE GROUND OR BELOW GROUND, AND SHOW THE METHOD OF | | | REQUIRED PROTECTION FOR THE LP TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK IS BELOW GROUND IT SHALL BE | | | ANCHORED PER NFPA 58 SEC.3-2.2.7 (H). IF ABOVE GROUND, | | | THE TANK SHALL BE SECURELY ANCHORED TO WITHSTAND 170 | | | MPH ULT WIND LOAD PER THE FLORIDA BUILDING CODE. | | | | | | ANY QUESTIONS REGARDING THESE REQUIREMENTS MAY BE | | | REFERRED TO THE CHIEF PLUMBING INSPECTOR AT | | | 561-805-6692. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-07-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-07-26 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-07-26 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2015-07-26 09:00:22 | 1) SUBMIT ALL DRAWINGS RELATED TO THIS PORTION OF THE | | | PROJECT.WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | | 2) SHT.0142-M-ADF-09 REFERS TO SHT. M-ADF-31 FOR | | | INFORMATION ON THE PROPANE TANK/PIPING. SUBMIT THIS | | | DRAWING FOR REVIEW. WPB AMEND. TO 2010 FBC SEC. | | | 107.2.1. | | | 3) SUBMIT COMPLETE PLANS FOR THE LP TANK & PIPING | | | SYSTEM. WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | | 4) SHT.0766-M-STD-09 - DETAIL # 1542102 - THE WYE SHALL | | | BE INSTALLED IN THE DIRECTION OF FLOE. REVISE THE | | | DETAIL. 2010 FPC SEC. 706.3. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2016-04-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-04-11 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-04-11 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-09-08 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-09-08 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-09-08 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
|