Plan Review Details - Permit 15060267
Plan Review Stops For Permit 15060267
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-12-10 Cont ID  
Sent By jwitmer Date 2015-12-10 Time 05:44 Rev Time 0.00
Received By jwitmer Date 2015-12-10 Time 05:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-09-04 Cont ID  
Sent By jwitmer Date 2015-09-04 Time 10:08 Rev Time 0.00
Received By jwitmer Date 2015-09-04 Time 10:08 Sent To  
Notes
2015-09-04 10:23:06BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15060267
 ADD: BLUE HERON / IBIS / COMMON AREAS
 CONT: SPECTRUM CABLE GROUP
 TEL: (561)641-3399
 E-MAIL: ?????????????? NOT SUPPLIED.
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. SEPT. 04/ 2015
 ACTION: DENIED
  
 1) THE SUBMITTED PLAN BY AMERICAN GAS LAMP WORKS IS
 JUST THAT, THE PERMIT APPLICATION INDICATES THE
 EXISTING LIGHT POLES ARE BEING CONVERTED OVER FROM GAS
 TO ELECTRIC & 6 NEW POLES. PLEASE NOTE ON THE
 MANUFACTURERS CUT SHEET THERE IS A FOUNDATION DESIGN
 BUT THERE IS NO WIND DESIGN CRITERIA LISTED TO
 CORRELATE WHAT WIND SPEED THE FOUNDATION WAS DESIGNED
 TO?
  
 2010 FBC-B 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 1.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
  
 1.2. RISK CATEGORY.
  
 1.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
  
 1.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 1.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 FOUNDATION DESIGN MUST BE FOR POLE AND POST MOUNTED
 BOULEVARD MODEL 3600 GLOBE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-09-02 Cont ID  
Sent By albarran Date 2015-09-02 Time 16:09 Rev Time 0.00
Received By albarran Date 2015-09-02 Time 15:36 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-09-01 Cont ID  
Sent By albarran Date 2015-09-01 Time 13:33 Rev Time 0.00
Received By albarran Date 2015-09-01 Time 12:51 Sent To B
Notes
2015-09-01 13:40:17I TRIED CONTACTING LORI FOR ANSWERERS TO THE BELOW
 MENTIONED QUESTIONS BUT SHE WAS OUT OF THE OFFICE.
 THE FOLLOWING ITEMS ARE STILL MISSING FROM THE
 SUBMITTAL FOR ACCEPTANCE:
 1. I NEED TO SEE SPEC SHEETS FOR THE PROPOSED
 TRANSFORMERS TO VERIFY CONFORMANCE WITH APPLICATION.
 2. WHAT IS THE EXISTING POWER SOURCE AND HOW WILL YOU
 BE TYING TO IT.
  
 THIS WAS ROUTED TO BLDG. AS THE POLES NEED TO MEET
 MINIMUM REQUIREMENTS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-06-09 Cont ID  
Sent By tklarge Date 2015-06-09 Time 12:33 Rev Time 0.00
Received By albarran Date 2015-06-09 Time 11:01 Sent To G
Notes
2015-06-09 11:43:27YOU SHALL PROVIDE A BETTER SCOPE OF WORK ALONG WITH THE
 WIRING METHOD PROPOSED FOR THIS INSTALLATION. ALL WORK
 SHALL BE DONE AS PER THE 2008 EDITION OF THE NEC.

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2015-08-20 Cont ID  
Sent By tklarge Date 2015-08-20 Time 14:11 Rev Time 0.00
Received By tklarge Date 2015-08-20 Time 14:10 Sent To  
Notes
2015-08-20 14:12:42THE GAS LINES BELONG TO FLORIDA PUBLIC UTILITIES AND
 THE BUILDING DEPARTMENT HAS NO JURISDICTION. NO GAS
 PERMIT IS REQUIRED FROM THE BUILDING DEPARTMENT. TIM
 LARGE

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2015-06-09 Cont ID  
Sent By tklarge Date 2015-06-09 Time 12:33 Rev Time 0.00
Received By tklarge Date 2015-06-09 Time 12:29 Sent To  
Notes
2015-06-09 12:33:141) SUBMIT INFORMATION AS TO WHAT IS BEING DONE TO THE
 EXISTING GAS LINES. ARE THE LINES BEING REMOVED OR
 ABANDONED? WILL THE LINES STILL BE LIVE? THE LINES
 SHALL BE VALVED AND CAPPED WHERE THEY ARE NOT IN USE.
 2) A PERMIT APPLICATION SHALL BE SUBMITTED FROM A
 PROPERLY LICENSED CONTRACTOR TO DO THE GAS WORK PER
 F.S. 489.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-12-10 Cont ID  
Sent By   Date   Time 05:44 Rev Time 0.00
Received By   Date 2015-12-10 Time 05:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-06-09 Cont ID  
Sent By tklarge Date 2015-06-09 Time 12:33 Rev Time 0.00
Received By tklarge Date 2015-06-05 Time 16:27 Sent To E
Notes
***NONE***