Plan Review Details - Permit 15060145
Plan Review Stops For Permit 15060145
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-07-07 Cont ID  
Sent By shill Date 2015-07-07 Time 12:39 Rev Time 0.00
Received By shill Date 2015-07-07 Time 12:39 Sent To  
Notes
2015-07-07 12:39:33****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. TWO IDENTICAL COLLATED SETS OF PLANS REQUIRED, FBC
 107. ONE SET HAS BEEN REVIEWED, BUT IT DOES NOT APPEAR
 THAT THE SETS ARE IDENTICAL.
  
 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR
 COMPONENTS AND CLADDING (ROOF COVERING, WINDOW, DOOR,
 VENT), FAC 9N 3, FBC 2010 RESIDENTIAL 301.
  
 3. FBC 2010 RESIDENTIAL 301.1, 301.2.1.1, 602.3,
 703.1.2, REVISE PLAN TO STATE METHOD USED FOR DESIGN.
 STRUCTURES ARE TO BE EITHER ENGINEERED USING ASCE 7 10
 OR ONE OF THE PRESCRIPTIVE METHODS.
  
 IF THE DESIGN IS NOT PRESCRIPTIVE AND IS ENGINEERED AND
 THE PLANS ARE NOT CERTIFIED BY A DESIGN PROFESSIONAL
 (ARCHITECT OR ENGINEER), CALCULATIONS ARE REQUIRED.
 (CALCULATIONS MAY BE REQUIRED EVEN IF CERTIFIED BY AN
 ARCHITECT OR ENGINEER IF ANY PORTION OF THE DESIGN DOES
 NOT APPEAR TO COMPLY WITH THE WIND RESISTANCE
 REQUIREMENTS OF THE FBC).
  
 IF PRESCRIPTIVE, PROVIDE THE PAGES USED FOR THE DESIGN.
  
 THE PLANS SUBMITTED APPEAR TO HAVE BEEN OBTAINED FROM A
 WEBSITE WHICH STATES THE FOLLOWING:
 DO THE PLANS INCLUDE THE REQUIREMENTS FOR FLORIDA?
 HURRICANE WIND SPEEDS?
 WE HAVE INFORMATION FOR BUILDING SHEDS IN FLORIDA. YOU
 CAN REQUEST THIS INFORMATION BY EMAILING OUR
 SUPPORT@ICREATABLES EMAIL. IT IS BASED ON PUBLISHED
 ENGINEERING FOR PALM BEACH COUNTY WHICH HAS THE MOST
 STRINGENT REQUIREMENTS.
 WIND EXPOSURE CATEGORY IS SITE DEPENDENT AND MUST BE
 DETERMINED BY THE ENGINEER OF RECORD BASED UPON SITE
 CONDITIONS UNLESS YOUR LOCAL BUILDING DEPARTMENT WILL
 ALLOW THE PUBLISHED ENGINEERING.
 ENGINEERING FOR MOST FLORIDA AREAS NEEDS TO BE DONE BY
 AN ENGINEER LICENSED IN FLORIDA. MOST OF THE ADDITIONS
 ARE FOR HURRICANE STRAPS AND ANCHORING TO THE GROUND.
 THE ENGINEER CAN WRITE ADDITIONAL ENGINEERING NOTES ON
 THE PLANS AND SUBMIT CALCULATIONS AS A SEPARATE
 DOCUMENT. SOME CITIES HAVE A PRINT OUT THAT CAN BE
 ATTACHED AS AN ADDENDUM THAT YOU SUBMIT WITH THE PLANS
 AFTER GETTING IT FROM THE BUILDING DEPARTMENT.
  
 DESIGN FOR WIND RESISTANCE APPLIES TO EVERY STRUCTURAL
 COMPONENT, FOUNDATION THROUGH THE ROOF. IT APPEARS THAT
 THE PLAN PROVIDED WAS NOT DESIGNED TO RESIST WIND
 (STRAPS/CONNECTORS NOT SHOWN).
  
 4. REVISE PLAN TO INCLUDE WIND DESIGN CRITERIA (WIND
 SPEED, EXPOSURE CLASSIFICATION), FBC 2010 RESIDENTIAL
 301.2.1.
  
 5. FBC 107, PROVIDE A STRUCTURAL SPEC FOR ALL LUMBER
 (SPECIES, STRENGTH, PT WHERE REQUIRED)
  
 6. TERMITE TREATMENT NOT SPECIFIED; REVISE PLAN TO
 INCLUDE, FBC 2010 RESIDENTIAL 318.1.
  
 7. SHOW GRADE IN RELATION TO THE SIDING, FBC
  
 8. PROVIDE A STRUCTURAL SPECIFICATION FOR THE SIDING
 WHICH ALSO ACTS AS SHEATHING, FBC 2010 RESIDENTIAL
 604.1 (IDENTIFICATION AND GRADE).
  
 9. SIDING FASTENERS TO COMPLY WITH FBC 2010 RESIDENTIAL
 703.4, REVISE PLAN TO SHOW COMPLIANCE.
  
 10. FBC 2010 RESIDENTIAL 703.1, WEATHER RESISTANT
 EXTERIOR REQUIRED, REVISE PLAN TO SHOW COMPLIANCE
 (SPECIFYING PAINT IS ACCEPTABLE).
  
 11. REMOVE SHEETS WHICH ARE NOT STRUCTURAL IN NATURE.
 BUILDING INSTRUCTIONS/TEMPLATES WERE PROVIDED BUT ARE
 NOT NEEDED FOR A BUILDING PERMIT.
  
 12. IF PLANS ARE NOT SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL, PLANS TO INCLUDE THE PRINTED NAME AND
 SIGNATURE OF THE INDIVIDUAL TAKING RESPONSIBILITY FOR
 THE DESIGN, FBC 107.
  
 13. ADVISORY ONLY - A COMPLETE PLAN REVIEW CANNOT BE
 DONE AT THIS TIME AS PLAN SUBMITTED DOES NOT APPEAR TO
 BE INTENDED FOR THIS WIND ZONE.
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2015-07-21 Cont ID  
Sent By fmittner Date 2015-07-21 Time 17:29 Rev Time 0.00
Received By fmittner Date 2015-07-21 Time 17:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-09-09 Cont ID  
Sent By ccole Date 2015-07-21 Time 09:51 Rev Time 0.00
Received By shill Date 2015-06-03 Time 15:36 Sent To Z
Notes
2015-07-07 12:40:177/7 TO SP DESK (NEEDS HISTORIC)
  

Review Stop Z ZONING
Rev No 1 Status F Date 2015-06-04 Cont ID  
Sent By shill Date 2015-09-09 Time 09:52 Rev Time 0.00
Received By sgraham Date 2015-06-04 Time 15:06 Sent To B
Notes
2015-06-04 15:07:556/4/15 ZONING FAILED
  
 1. SUBMIT TWO UP TO DATE SURVEYS HIGHLIGHTING THE
 LOCATION OF THE SHED


Account Summary | Usage Policy | Privacy Policy