Plan Review Details - Permit 15060123
| Plan Review Stops For Permit 15060123 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-06-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-22 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-06-22 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-08-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-08-17 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-08-17 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-07-16 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-16 |
Time |
19:11 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-07-16 |
Time |
18:42 |
Sent To |
I |
|
| Notes |
| 2015-07-16 19:36:19 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE | | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | | THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE | | | CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW. | | | | | | 1. NEC 408.4 REQUIRES THAT YOU PROVIDE AN ACCURATE | | | PANEL SCHEDULE IDENTIFYING ALL CIRCUITS. | | | 2. NEC 230.72(C) REQUIRES THAT ALL OCCUPANT HAVE ACCESS | | | TO THE DISCONNECTING MEANS FOR THEIR UNITS, INDICATE ON | | | THE PLANS THE LOCATION OF SUCH. | | | 3. NEC 220.16 PROVIDE THE REQUIRED ELECTRICAL LOAD | | | CALCS IN ACCORDANCE WITH 220.12 EDUCATIONAL OCCUPANCY 3 | | | W/SQ FT. | | | 4. NEC 210.8(7) REQUIRES ALL OUTLETS WITH 6' OF A SINK | | | TO BE GFI PROTECTED. | | | 5. NEC 600.5 REQUIRES A DEDICATED SIGN OUTLET ABOVE | | | EVERY ENTRANCE DOOR. | | | 6. FBC-E SECTION 505 HAS SPECIFIC AND MANDATORY | | | LIGHTING REQUIREMENTS WHICH SHALL BE ADDRESSED. | | | 7. FBC-B 1006.2 HAS SPECIFIC EMERGENCY LIGHTING | | | REQUIREMENTS WHICH DO NOT APPEAR TO HAVE BEEN MET. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-06-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-06-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-06-05 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2015-06-05 12:21:55 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | EXIT SIGNS AND EMERGENCY LIGHTS SHALL BE LOCATED DURING | | | FIRE INSPECTION AND CONFIRMED IN THE REQUIRED AREAS | | | THAT MAY NOT BE SHOWN ON THE SUBMITTED PLAN. | | | | | | THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE | | | FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND | | | COMPLIANCE. ANY REMOVAL AND/OR CONSTRUCTION OF WALLS | | | REQUIRES AN EVALUATION. | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-08-17 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-08-17 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-08-17 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-07-16 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-16 |
Time |
19:36 |
Rev Time |
|
| Received By |
albarran |
Date |
2015-06-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-07-16 19:39:42 | 7/16/15 - FAILED ELECTRICAL REVIEW AS NOTED. CONTRACTOR | | | NOTIFIED VIA EMAIL. SENT TO SMALL DENIED BIN "C". MA | | 2015-06-03 12:37:51 | B21 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2015-06-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-22 |
Time |
13:22 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2015-06-22 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2015-06-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-06-26 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-06-26 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2015-06-26 11:41:26 | MECHANICAL PROVISOS: 6/26/15 | | | | | | 1) REQUIRED FIRE DAMPERS @ DUCT/RATED WALL PENETRATIONS | | | SHALL BE EXISTING AND FUNCTION OR A REVISON TO THE PLAN | | | IS REQUIRED FOR NEW DAMPER INSTALLATIONS. | | | 2) CONTRACTOR TO VERIFY REQUIRED O/A FOR EACH STUDIO IS | | | BEING PROVIDED OR ADJUST SYSTEM TO MEET THE DEMAND. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-07-10 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-07-10 |
Time |
16:53 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2015-06-05 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
|