| Notes |
| 2015-07-07 11:32:43 | THE SCOPE OF THIS PERMIT IS FOR THE REPLACEMENT OF A | | | PREVIOUSLY INSTALLED ACCESS CONTROL SYSTEM. THEREFORE | | | DOOR SWING REQUIREMENTS ARE NOT BEING EVALUATED AT THIS | | | TIME. THIS DOES NOT PRECLUDE THE FIRE MARSHALL FROM | | | RE-EVALUATING THIS CHOICE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-06-10 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-06-10 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-06-10 |
Time |
17:02 |
Sent To |
I |
|
| Notes |
| 2015-06-10 17:04:37 | FBC-107.2.1 CLEARLY STATES THAT CONSTRUCTION DOCUMENTS | | | SHALL BE PRESENTED IN A WELL DIMENSION MANNER. | | | FURTHERMORE, YOU SHALL PROVIDE DOCUMENTATION THAT | | | SYSTEM WILL OPERATE IN A FAIL-SAFE FASHION. YOUR | | | DRAWING SHALL ALSO INCLUDE THE TYPE OF WIRE BEING USED | | | AND HOW IT WILL BE RUN. NEC HAS SPECIFIC CODE | | | REQUIREMENTS FOR LOW VOLTAGE CABLE AS WELL. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-06-26 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-06-26 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-06-26 |
Time |
16:33 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-06-02 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-06-02 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-06-02 |
Time |
13:27 |
Sent To |
E |
|
| Notes |
| 2015-06-02 13:34:08 | 200 NORTHPOINT PARKWAY | | | PERMIT #15060093 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PLANS ARE ILLEGIBLE, NOT TO SCALE, DO NOT CONTAIN AN | | | ADDRESS. PLANS DO NOT CLEARLY INDICATE THE PROPOSED | | | LOCATIONS (INGRESS OR EGRESS) FOR THE CARD READERS. | | | | | | SUBMIT PRODUCT DATA CUTSHEETS. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-07-07 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-07 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-06-16 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2015-07-07 11:36:08 | 7/7/15 - PASSED ELECTRICAL REVIEW AS NOTED. CONTRACTOR | | | NOTIFIED VIA EMAIL. SENT TO SMALL READY BIN "J". MA | | 2015-06-16 13:03:23 | TO FIRE BOX | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-06-10 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-06-10 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-06-02 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2015-06-10 17:16:00 | SENT TO SMALL DENIED BIN "J" | | 2015-06-02 12:16:05 | ROUTED TO FIRE |
|
|
|