Plan Review Details - Permit 15060074
Plan Review Stops For Permit 15060074
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-10-23 Cont ID  
Sent By skennedy Date 2017-10-23 Time 08:33 Rev Time 0.00
Received By skennedy Date 2017-10-23 Time 08:33 Sent To  
Notes
2017-10-23 08:34:20REVIEWED FOR REISSUANCE. ORIGINAL PLANS TO BE USED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-08-10 Cont ID  
Sent By skennedy Date 2015-08-10 Time 08:33 Rev Time 0.00
Received By skennedy Date 2015-08-10 Time 08:33 Sent To  
Notes
2015-08-10 08:37:592ND REVIEW: FBC 2010
  
 THIS PLAN DOES NOT COMPLY WITH FBC 107 AS TO SCALE
 BELOW 1/8'/FOOT, HOWEVER, DUE TO THE LIMITED SCOPE OF
 WORK, IT IS PROVISIONALL APPROVED SUBJECT TO THE
 BUILDING INSPECTOR REQUIRING ADDITIONAL INFORMATION.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-06-19 Cont ID  
Sent By jwitmer Date 2015-06-19 Time 06:31 Rev Time 0.00
Received By jwitmer Date 2015-06-19 Time 06:00 Sent To  
Notes
2015-06-19 06:24:37BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15060074
 ADD: 1200 S. FLAGLER DR. SUITE # 1603
 CONT: CAMBRIDGE CONSTRUCTION
 TEL: ( 561)784-3722
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JUNE 19/ 2015
 ACTION: DENIED
  
 1) AN ITEMIZED LIST OF PROPOSED WORK WAS SUBMITTED, NO
 PLANS SHOWING THE AREA AND DESCRIPTION OF WORK TO BE
 COMPLETED WITHIN THIS PROJECT.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 107.2.1.3
 ADDITIONAL DATA. THE BUILDING OFFICIAL MAY REQUIRE
 DETAILS, COMPUTATIONS, STRESS DIAGRAMS, AND OTHER DATA
 NECESSARY TO DESCRIBE THE CONSTRUCTION OR INSTALLATION
 AND THE BASIS OF CALCULATIONS. ALL DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA REQUIRED BY THE
 BUILDING OFFICIAL TO BE PREPARED BY AN ARCHITECT OR
 ENGINEER SHALL BE AFFIXED WITH THEIR OFFICIAL SEAL,
 SIGNATURE AND DATE AS STATE LAW REQUIRES.
  
 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
 THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS
 MANAGEMENT.
  
 107.3.5 107.3.5.1 COMMERCIAL BUILDINGS. MINIMUM PLAN
 REVIEW CRITERIA FOR BUILDINGS. THE EXAMINATION OF THE
 DOCUMENTS BY THE BUILDING OFFICIAL SHALL INCLUDE THE
 FOLLOWING MINIMUM CRITERIA AND DOCUMENTS:
 107.3.5.1.1 BUILDING
 A FLOOR PLAN
 OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS
 SHALL BE DETERMINED.
 MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE
 TABLE 503).
 FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL INCLUDE
 THE FOLLOWING COMPONENTS:
 FIRE-RESISTANT SEPARATIONS
 FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION
 PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS
 FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: SCHEMATIC FIRE
 SPRINKLERS
 STRUCTURAL REQUIREMENTS SHALL INCLUDE: DROPPED CEILINGS
 AND SOFFIT DESIGN AND ATTACHMENT.
 INTERIOR REQUIREMENTS SHALL INCLUDE THE FOLLOWING:
 INTERIOR FINISHES (FLAME SPREAD/SMOKE DEVELOPMENT)
 LIGHT AND VENTILATION
 SANITATION: TYPE OF TILE BACKING MATERIAL
 SOUND PROOFING OF TENANT WALLS AND FLOOR SYSTEMS.
  
 2) BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION: NOTE
 PROTECTO WRAP MEETS ALL THREE OF THE ASTM TEST, MISSING
 FROM THE REPORTS IS THE FLAME SPREAD INDEX TESTING
 REPORT.
  
 2A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 2B) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-08-10 Cont ID  
Sent By skennedy Date 2015-08-10 Time 08:33 Rev Time 0.00
Received By skennedy Date 2015-08-10 Time 08:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-06-19 Cont ID  
Sent By skennedy Date 2015-06-19 Time 12:12 Rev Time 0.00
Received By skennedy Date 2015-06-19 Time 12:12 Sent To  
Notes
2015-06-19 12:26:571ST REVIEW: FBC 2010
  
 PROVIDE A PLANN AND SHOW PLUMBING AND ELECTRICAL
 ALTERATIONS WITH ADEQUATE DETAIL TO DETERMINE CODE
 COMPLIAANCE PER FBC 107.
 SEE BUILDING REVIEW COMMENTS.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-08-06 Cont ID  
Sent By pleduc Date 2015-08-06 Time   Rev Time 0.00
Received By pleduc Date 2015-08-06 Time 14:36 Sent To P
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-06-03 Cont ID  
Sent By pleduc Date 2015-06-03 Time   Rev Time 0.00
Received By pleduc Date 2015-06-03 Time 11:39 Sent To  
Notes
2015-06-03 11:44:31THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THERE IS INSUFFICIENT DETAILED TO REVIEW AND/OR APPROVE
 THIS PROPOSED PROJECT.
  
 PROVIDE EXISTING AND PROPOSED DRAWINGS.
  
 THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE
 FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND
 COMPLIANCE. ANY REMOVAL AND/OR CONSTRUCTION OF WALLS
 REQUIRES AN EVALUATION.
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-10-23 Cont ID  
Sent By skennedy Date 2017-10-23 Time 08:33 Rev Time 0.00
Received By skennedy Date 2017-10-23 Time 08:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-08-10 Cont ID  
Sent By skennedy Date 2015-08-10 Time 08:39 Rev Time 0.00
Received By skennedy Date 2015-08-04 Time 12:55 Sent To  
Notes
2015-08-04 12:56:51RESUB ROUTED TO FIRE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-06-19 Cont ID  
Sent By skennedy Date 2015-06-19 Time 12:27 Rev Time 0.00
Received By skennedy Date 2015-06-02 Time 15:24 Sent To  
Notes
2015-06-02 15:24:14****EXPEDITED****
 B08
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-08-10 Cont ID  
Sent By tklarge Date 2015-08-10 Time 05:22 Rev Time 0.00
Received By tklarge Date 2015-08-10 Time 05:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-06-19 Cont ID  
Sent By skennedy Date 2015-06-19 Time 12:27 Rev Time 0.00
Received By skennedy Date 2015-06-19 Time 12:27 Sent To  
Notes
2015-06-19 12:27:351ST REVIEW: FBC 2010
  
 PROVIDE A PLANN AND SHOW PLUMBING AND ELECTRICAL
 ALTERATIONS WITH ADEQUATE DETAIL TO DETERMINE CODE
 COMPLIAANCE PER FBC 107.
 SEE BUILDING REVIEW COMMENTS.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  