|
 |
 |
 |
 |
 |
Plan Review Details - Permit 15060013
| Plan Review Stops For Permit 15060013 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-06-22 |
|
|
Cont ID |
|
| Sent By |
RMCDOUGA |
Date |
2015-06-22 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-22 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-10-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-10-15 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-07-07 |
|
|
Cont ID |
|
| Sent By |
DHAYES |
Date |
2015-07-07 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-07-07 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2015-07-07 15:44:08 | ITEMS REQUESTED IN INITIAL ELECTRICAL PROVISO HAVE NOT | | | BEEN COMPLIED WITH. COMPLY WITH COMMENTS LISTED BELOW: | | | | | | 1) RECESSED LIGHTS. REQUIRES THAT RECESSED LUMINAIRES | | | BE SEALED, AIR TIGHT, IC RATED. 2010 FBC 402.4.5 | | | | | | 2) PROVIDE THE ARC FAULT CALCULATION TO INDICATE THE | | | AIC RATING ON SERVICE SWITCHGEAR. NEC 110.9 AND 110.10 | | | | | | 3) PROVIDE CUT SHEETS ON INFLOOR UP LIGHTS AND DROP | | | DOWN SCREENS TO INDICATE COMPLIANCE WITH THE NEC 110.3 | | | INCLUDE MANUFACTURER PRODUCT INFORMATION ON LIGHTING | | | CONTROL SYSTEM. | | | | | | 4) NEW RECEPTACLES MUST BE TAMPER RESISTANT. THOSE | | | OUTLETS IN WET LOCATIONS SHALL BE GFI & WEATHER | | | RESISTANT NEC 406.8(B), 406.11 | | | | | | 5) INDICATE CIRCUITRY AND DISCONNECTS REQUIERD FOR | | | TANKLESS WATER HEATERS. | | | | | | 6) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | ARE REQUIRED FOR GENERATOR. SWIMMING POOL, SECURITY AND | | | AUDIO/VIDEO, | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421. | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-07-07 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-07-07 |
Time |
15:44 |
Rev Time |
|
| Received By |
dhayes |
Date |
2015-06-01 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2015-06-22 |
|
|
Cont ID |
|
| Sent By |
RMCDOUGA |
Date |
2015-06-22 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-22 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-22 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-22 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-06-30 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2015-06-30 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2015-06-30 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |