Plan Review Details - Permit 15051314
| Plan Review Stops For Permit 15051314 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-07-20 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-07-20 |
Time |
06:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-07-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-07-17 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-07-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-07-17 09:35:26 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15051314 | | | ADD: 400 N. FLAGLER DR. SUITE # 703 | | | CONT: CUSTOM CONSTRUCTION | | | TEL: (561)670-0779 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: FRI. JUNE 17/2015 | | | ACTION: DENIED | | | | | | 1A) SEMI-COMPLIED. THE PRODUCT APPROVALS HAVE NOT BEEN | | | REVIEWED BY THE DESIGNER OF RECORD AS FAR AS PRESSURES. | | | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | | | | 1B) THE CONCERN IS WITH THE EASTERN FD 8100 SLIDING | | | GLASS DOOR SYSTEM PAGE 4 OF 6 IN THE PRODUCT APPROVAL | | | THE DESIGN PRESSURE IS +/- 60 PSF FOR AN OPENING SIZE | | | OF 240 IN. X 120 IN. PLEASE HAVE EASTERNS ENGINEER | | | PROVIDE A RATIONAL ANALYSIS FOR THE PRESSURES FOR THE | | | VAROIUS SIZE OPENINGS. FOR SMALLER OPENINGS THE | | | PRESSURES RISE AS WELL AS THE POSITIVE PRESSURES, THE | | | BUILDING IS A 23 STORY HIGH RISE IN AN EXPOSURE D. | | | 107.2.4 EXTERIOR WALL ENVELOPE. CONSTRUCTION DOCUMENTS | | | FOR ALL BUILDINGS SHALL DESCRIBE THE EXTERIOR WALL | | | ENVELOPE IN SUFFICIENT DETAIL TO DETERMINE COMPLIANCE | | | WITH THIS CODE.THE CONSTRUCTION DOCUMENTS SHALL INCLUDE | | | MANUFACTURER?S INSTALLATION INSTRUCTIONS THAT PROVIDE | | | SUPPORTING DOCUMENTATION THAT THE PROPOSED PENETRATION | | | AND OPENING DETAILS DESCRIBED IN THE CONSTRUCTION | | | DOCUMENTS MAINTAIN THE WEATHER RESISTANCE OF THE | | | EXTERIOR WALL ENVELOPE. THE SUPPORTING DOCUMENTATION | | | SHALL FULLY DESCRIBE THE EXTERIOR WALL SYSTEM WHICH WAS | | | TESTED, WHERE APPLICABLE, AS WELL AS THE TEST PROCEDURE | | | USED. | | | | | | 2) COMPLIED. FLOOR INSULATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-06-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-22 |
Time |
08:44 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2015-06-22 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-06-22 08:44:51 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15051314 | | | ADD: 400 N. FLAGLER DR. SUITE # 703 | | | CONT: CUSTOM CONSTRUCTION | | | TEL: (561)670-0779 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JUNE 22/2015 | | | ACTION: DENIED | | | | | | 1) SHEET # 1 INDICATES NEW SLIDDING GLASS DOORS AND THE | | | EXPOSURE GIVEN IS A C EXPOSURE. THIS EXPOSURE IS | | | CONSIDERED A D EXPOSURE 2010 FBC-B 1609.4.3. PLEASE | | | PROVIDE THE PRESSURES FOR THE 240 FT. HIGH, HIGH RISE | | | IN EXPOSURE D. THE UNKNOWN VARIABLE IS THIS UNIT IN A | | | WALL ZONE 4 OR A WALL ZONE 5, A END ZONE? | | | | | | 2) THE PLANS ALSO INDICATE THE REMOVAL OF FLOOR | | | COVERINGS AND THE USE OF SAM 3 90, PLEASE SUBMIT THE | | | ACTUAL TEST REPORTS FOR THIS PRODUCT AND FOR THE FLOOR | | | THICKNESS AT 6 INCHES, UNLESS VERIFIED BY AN ENGINEER. | | | THE TEST REPORTS NEED TO BE APPROVED TO: | | | | | | 2FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. FLOOR/CEILING | | | ASSEMBLIES BETWEEN DWELLING UNITS OR BETWEEN A DWELLING | | | UNIT AND A PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE | | | SHALL HAVE AN IMPACT INSULATION CLASS (IIC) RATING OF | | | NOT LESS THAN 50 (45 IF FIELD TESTED) WHEN TESTED IN | | | ACCORDANCE WITH ASTM E 492. | | | | | | 2B) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 2C) FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-07-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-07-16 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-07-16 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-05-30 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-05-30 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-05-30 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2015-05-30 13:58:16 | 5/30/2015 | | | PROJECT: GIBB RENNOVATION | | | PERMIT#: 15051314 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | | COMMENTS: | | | | | | 1) CHANGE THE "CODE" NOTE ATE THE BOTTOM RIGHT ON SHEET | | | 1 TO READ THE 2008 EDITION OF THE NFPA 70 (NEC) | | | NATIONAL ELECTRICAL CODE. | | | | | | 2) RECEPTACLES SHALL BE INSTALLED SUCH THAT NO POINT | | | MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY WALL | | | SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE | | | OUTLET. NEC 210.52 | | | | | | 3) ALL NEW GENERAL PURPOSE OUTLETS MUST BE AFCI | | | PROTECTED. NEC 210.12 | | | | | | 4) NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | | | | 5) PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE | | | BATHROOMS. NEC 210.11 (C) | | | | | | 6) EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE | | | LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND | | | SPECIFIC PURPOSE OR USE. PROVIDE THE OCPD AND | | | CORRESPONDING WIRE SIZE FOR NEC 408.4 | | | | | | 7) RECESSED LUMINAIRES INSTALLED IN THE BUILDING | | | THERMAL ENVELOPE SHALL BE IC AND AIR TIGHT RATED AND | | | SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND | | | UNCONDITIONED SPACES. FBC-E 502.3.8 RECESSED LIGHTING. | | | | | | 8) INDICATE OR VERIFY THE INSTALLATION OF SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL | | | 314 AND 315. | | | | | | 9))BOXES LISTED SPECIFICALLY FOR THIS APPLICATION SHALL | | | BE USED FOR RECEPTACLES LOCATED IN THE FLOOR. NEC | | | 314.27(C) | | | | | | 10) AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED | | | IN BATHROOMS WITHIN (3 FT) OF THE OUTSIDE EDGE OF EACH | | | BASIN. NEC 210.52 (D) | | | | | | 11) PROVIDE A LIGHTING FIXTURE SCHEDULE TO IN CLUDE THE | | | UNDER CABINET LIGHTING MENTIONED IN THE NOTE ON SHEET | | | 1. ALL LIGHTING TO BE IN COMPLIANCE WITH THE FBC-E, NEC | | | 410, AND NEC 110.3 | | | | | | 12) OCCUPIABLE BALCONIES AND PORCHES OVER 20 SQ FT MUST | | | HAVE A RECEPTACLE OUTLET GFCI PROTECTED. NEC | | | 210.52(E)(3). | | | | | | 13) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | ARE REQUIRED FOR FIRE ALARM, FIRE SPRINKLER, SECURITY, | | | CCTV, AUDIO/VIDEO, NETWORK, DATA, AND, COMMUNICATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-07-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-07-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-07-09 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2015-07-09 11:24:38 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PROVISO: | | | | | | THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE | | | FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND | | | COMPLIANCE. ANY REMOVAL AND/OR CONSTRUCTION OF WALLS | | | REQUIRES AN EVALUATION. | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-06-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-06-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-06-03 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2015-06-03 13:40:45 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PROVISO: | | | | | | THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE | | | FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND | | | COMPLIANCE. ANY REMOVAL AND/OR CONSTRUCTION OF WALLS | | | REQUIRES AN EVALUATION. | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-07-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-07-17 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-07-07 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-06-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-06-23 |
Time |
14:53 |
Rev Time |
|
| Received By |
hmoser |
Date |
2015-05-29 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2015-06-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-06-23 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-06-23 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2015-06-23 14:53:29 | NO MECHANICAL WORK BEING DONE AT THIS TIME HM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-07-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-07-16 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-07-16 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-06-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-16 |
Time |
06:15 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-16 |
Time |
05:54 |
Sent To |
|
|
| Notes |
| 2015-06-16 05:40:32 | THE PLANS ARE VAGUE AS TO THE SCOPE OF PLUMBING WORRK | | | TO BE DONE UNDER THIS PERMIT. INDICATE ON THE PLANS | | | WHAT IS EXISTING TO REMAIN AND WHAT IS TO BE REPLACED. | | | WPB AMEND. TO FBC 2010 FBC SEC.107.2.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
|