Plan Review Details - Permit 15051275
| Plan Review Stops For Permit 15051275 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-06-19 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-06-19 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-06-19 |
Time |
09:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-06-02 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-06-02 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-06-02 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2015-06-02 09:46:23 | 6/2/2015 | | | PROJECT: SOLAR EATER HEATER | | | PERMIT#: 15051275 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | | COMMENTS: | | | | | | 1) THE PLANS DO NOT SHOW THAT THE PUMP IS A PLUG IN | | | UNIT. PROVIDE THE MANUFACTURER DOCUMENTATION ON THE | | | PUMP. INDICATE ON THE PLAN IF THERE IS AN EXISTING | | | RECEPTACLE FOR THE PUMP TO PLUG INTO. IF NOT REVISE THE | | | PLAN TO INDICATE REQUIRED RECEPATCLE OUTLET(S). A | | | SEPARATE ELECTRIC PERMIT IS REQUIRED FOR THE | | | INSTALATION OF ANY ELECTRICAL CIRCUITRY THAT IS | | | REQUIRED AND NOT CURRENTLY EXISTING TO REMAIN. WPB | | | AMEND. TO 2010 FBC SEC.107.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-06-19 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-06-19 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-06-18 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2015-06-18 06:52:42 | SENT TO T LARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-06-02 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-06-02 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-06-19 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-19 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-19 |
Time |
05:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-06-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-02 |
Time |
04:41 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-02 |
Time |
03:53 |
Sent To |
E |
|
| Notes |
| 2015-06-02 04:43:44 | SENT TO ELEC. TO DETERMINE IF ELECTRIC PERMIT IS | | | REQUIRED. | | 2015-06-02 04:41:29 | 1) SUBMIT A PIPING DIAGRAM SHOWING THE PIPING, PUMP, | | | VALES, TYPE OF PIPE MATERIAL, ETC.FROM THE COLLECTOR TO | | | THE WATER STORAGE TANK. WPB AMEND. TO 2010 FBC SEC. | | | 107.2.1. | | | 2) THE HAND DRAWN PLANS SHOW THE COLLECTOR LOCATED ON A | | | FLAT ROOF BUT DRAWING SL-3C SSHOWS THE PLANS FOR A | | | SLOPED ROOF. SUBMIT SIGNED AND SEALED PLANS FOR THE | | | COLLECTOR LOCATED PN A FLAT ROOF. | | | 3) SUBMIT WIND LOAD ENGINEERING FOR THE COLLECTOR | | | LOCATED ON A FLAT ROOF. WPB AMEND. TO 2010 FBC SEC. | | | 107.2.1. | | | 4) THE CONNECTION FROM THE POTABLE WATER SYSTEM SHALL | | | BE EQUIPPED WITH BACKFLOW PROTECTION PER 2010 FBCR, | | | SEC.M2301.5, P2902.5.5. (SEE EXCEPTION). | | | 5) THE PLANS DO NOT SHOW THAT THE PUMP IS A PLUG IN | | | UNIT OR AN EXISTING REPTACLE IF IT IS, AND THERE IS | | | ALSO A SPEC SHEET FOR A TEMPERATURE CONTROL DEVICE. A | | | SEPARATE ELECTRIC PERMIT MAY BE REQUIRED. WPB AMEND. TO | | | 2010 FBC SEC. 107.2.1. | | | 6) SECTION 403.4.3.2.3 OF 2010 FL. ENERGY CODE REQUIRES | | | THAT THE SOLAR COLLECTORS BE TESTED IN ACCORDANCE WITH | | | ISO STANDARD 9806 AND SRCC STANDARD TM-1. SUBMIT | | | VERIFICATION. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
|