| Plan Review Stops For Permit 15051094 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2015-07-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-13 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-13 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2015-07-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-10 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-10 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2015-07-10 14:29:56 | RESIDENTIAL (R3) RE-ROOF, THIRD BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC-RESIDENTIAL. | | | | | | ****ORIGINAL COMMENT: | | | 1- NEW COMMENT TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301 OF 2010- FBC-RESIDENTIAL: | | | TU PLUS UNDERLAYMENT SUBMITTED: NEED TO IDENTIFY | | | UNDERLAYMENT WITH DESIGN PRESSURES THAT MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, INCLUDING THE CORNER | | | AREAS. NOTE: THIS HOUSE IS LOCATED IN EXPOSURE "C". THE | | | REQUIRED DESIGN PRESSURES FOR CORNER AREAS IS -95.12 | | | PSF. | | | | | | ***NO ASDDRESSED. | | | INFORMATION SUBMITTED WAS FLORIDA PRODUCT APPROVAL | | | FL7473-R6. THIS IS A ROOF TILE PRODUCT APPROVAL NOT | | | UNDERLAYMENT. MY ORIGINAL COMMENT WAS FOR FLORIDA | | | PRODUCT APPROVAL UNDERLAYMENT SUBMITTED, NOT THE ROOF | | | TILE. SEE ORIGINAL COMMENT ABOVE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-06-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-06-26 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-06-26 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2015-06-26 16:31:32 | | | | NOTE: THERE IS NOT NEW INFORMATION SUBMITTED AFTER MY | | | REVIEW ON 6/25/15. | | | | | | | | | RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC-RESIDENTIAL. | | | | | | 1- ORIGINAL COMMENT: | | | "FBC 109, PROVIDE A COPY OF THE CONTRACT FOR THIS JOB." | | | | | | OK. SUBMITTED. TOTAL VALUE $26,500. VALUATION AND FEES | | | WILL BE ADJUSTED ACCORDINGLY | | | | | | 2 - ORIGINAL COMMENT: | | | "ON THE FOAM ADHESIVE PRODUCT APPROVAL, INDICATE METHOD | | | OF INSTALLATION PROPOSED (TABLE 1), FBC 2010 | | | RESIDENTIAL 301". | | | | | | OK. | | | | | | 3. ORIGINAL COMMENT: | | | "THE TILE PRODUCT APPROVAL IS NOT THE MOST CURRENT | | | VERSION; PLEASE PROVIDE FL 7473-R5 AND ASSOCIATED | | | INSTALLATION INSTRUCTIONS/EVALUATION REPORT". | | | (OK. FLORIDA WEBSITE INFORMATION IS FL7473-R3) | | | | | | 4- NEW COMMENT TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301 OF 2010- FBC-RESIDENTIAL: | | | TU PLUS UNDERLAYMENT SUBMITTED: NEED TO IDENTIFY | | | UNDERLAYMENT WITH DESIGN PRESSURES THAT MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, INCLUDING THE CORNER | | | AREAS. NOTE: THIS HOUSE IS LOCATED IN EXPOSURE "C". THE | | | REQUIRED DESIGN PRESSURES FOR CORNER AREAS IS -95.12 | | | PSF. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-06-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-06-25 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-06-25 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2015-06-25 16:42:23 | RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC-RESIDENTIAL. | | | | | | 1- ORIGINAL COMMENT: | | | "FBC 109, PROVIDE A COPY OF THE CONTRACT FOR THIS JOB." | | | OK. SUBMITTED. TOTAL VALUE $26,500. VALUATION AND FEES | | | WILL BE ADJUSTED ACCORDINGLY | | | | | | 2 - ORIGINAL COMMENT: | | | "ON THE FOAM ADHESIVE PRODUCT APPROVAL, INDICATE METHOD | | | OF INSTALLATION PROPOSED (TABLE 1), FBC 2010 | | | RESIDENTIAL 301". | | | OK. | | | | | | 3. ORIGINAL COMMENT: | | | "THE TILE PRODUCT APPROVAL IS NOT THE MOST CURRENT | | | VERSION; PLEASE PROVIDE FL 7473-R5 AND ASSOCIATED | | | INSTALLATION INSTRUCTIONS/EVALUATION REPORT". | | | (OK. FLORIDA WEBSITE INFORMATION IS FL7473-R3) | | | | | | 4- NEW COMMENT TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301 OF 2010- FBC-RESIDENTIAL: | | | TU PLUS UNDERLAYMENT SUBMITTED: NEED TO IDENTIFY | | | UNDERLAYMENT WITH DESIGN PRESSURES THAT MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, INCLUDING THE CORNER | | | AREAS. NOTE: THIS HOUSE IS LOCATED IN EXPOSURE "C". THE | | | REQUIRED DESIGN PRESSURES FOR CORNER AREAS IS -95.12 | | | PSF. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-06-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-06-11 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-06-11 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2015-06-11 11:07:34 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FBC 109, PROVIDE A COPY OF THE CONTRACT FOR THIS | | | JOB. | | | | | | 2. ON THE FOAM ADHESIVE PRODUCT APPROVAL, INDICATE | | | METHOD OF INSTALLATION PROPOSED (TABLE 1), FBC 2010 | | | RESIDENTIAL 301. | | | | | | 3. THE TILE PRODUCT APPROVAL IS NOT THE MOST CURRENT | | | VERSION; PLEASE PROVIDE FL 7473-R5 AND ASSOCIATED | | | INSTALLATION INSTRUCTIONS/EVALUATION REPORT. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-07-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-13 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-13 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-07-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-10 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-08 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-06-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-06-26 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-06-26 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-06-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-06-25 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-06-23 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-06-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-06-11 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-06-05 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|