| 2015-05-27 10:40:17 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15051081 |
| | ADD: 1475 7TH ST |
| | CONT: PAYTON ROOFING |
| | TEL: (954)968-8171 |
| | E-MAIL:[email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE:WED. MAY 27/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) THE SUBMITTED ROOFING FORM 100 SECTION D LIST THIS |
| | JOB AS A EXPOSURE B, PLEASE CORRECT TO EXPOSURE C ALSO |
| | SEE MULTIPLIERS UNDER 2010 RESIDENTIAL CODE TABLE |
| | R301.2(3). 15 FT. / 1.21. PROVIDE NEW FORM WITH |
| | CORRECTED PRESSURES. |
| | |
| | 2) (2) SETS OF FORM 100 WERE SUBMITTED, AND ONLY 1 SET |
| | OF PRODUCT APPROVALS FOR THE SHINGLES NOA: 14-1022.16 |
| | AND FLAT ROOF NOA 13-0204.14 WERE SUBMITTED. (2) SETS |
| | OF PRODUCT APPROVALS ARE REQUIRED FOR ISSUANCE. 1 SET |
| | FOR RECORD RETENSION & 1 SET FOR THE INSPECTOR IN THE |
| | FIELD. |
| | |
| | 3) THE FLAT DECK PRODUCT APPROVAL 13-0204.14 NO |
| | SUB-SYSTEM WAS IDENTIFIED BY CIRCLING THE SUB-SYSTEM TO |
| | BE INSTALLED. THERE ARE ONLY 3 SYSTEMS FOR |
| | NON-INSULATED WOOD DECKS PAGES 13,14 & 15. PAGE 13 |
| | LIMITATION # 9 APPLIES. FOR PAGES 14 & 15 LIMITATION # |
| | 7 REQUIRES EITHER A FLORIDA ARCHITECT OR ENGINEER TO |
| | SUPPLY RAS 117 CALCULATIONS. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |