| Plan Review Stops For Permit 15051022 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-10-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-28 |
Time |
06:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-28 |
Time |
06:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-01 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-01 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2015-10-01 17:08:50 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15051022 | | | ADD: 1517 CAMERON SAMUELS LANE | | | CONT: A& G CONCRETE POOLS, INC | | | TEL: ( 772)878-7752 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | | | | | | | NOTICE!!!!!!!!!!!!!!!!!!!!!!!!!: CHAPTER 553.80(2)(B) | | | FLORIDA STATUTES STATES THAT A LOCAL GOVERNMENT SHALL | | | IMPOSE A FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF | | | PLANS ARE REJECTED (3) OR MORE TIMES FOR REPEATED | | | FAILURE TO CORRECT A CODE VIOLATION. | | | | | | | | | | | | 3RD REVIEW | | | DATE: THURS. OCT. 01/2015 | | | ACTION: DENIED | | | | | | 1) 3RD REVIEW ONLY ONE SET OF AQUATIC ACCESS SALES | | | BROCHURE WAS SUBMITTED. COMPLIANCE WITH THE 2010 | | | FBC-ACCESSIBILITY CODE CAN NOT BE DETERMINED PLEASE | | | SHOW COMPLIANCE WITH: | | | 2010 FBC-ACCESSIBILITY COCE; | | | | | | 1009.2.2 SEAT LOCATION OK | | | . | | | 1009.2.4 SEAT HEIGHT THE LOW HEIGHT RANGE DOES NOT MEET | | | THE REQUIREMENT OF 16 INCHES. | | | | | | 1009.2.5 SEAT WIDTH OK | | | | | | 1009.2.6 FOOT REST AND ARMREST DOES NOT INDICATE CODE | | | COMPLIANCE. FOOTRESTS SHALL BE PROVIDED AND SHALL MOVE | | | WITH THE SEAT. IF PROVIDED, THE ARMREST POSITIONED | | | OPPOSITE THE WATER SHALL BE REMOVABLE OR SHALL FOLD | | | CLEAR OF THE SEAT WHEN THE SEAT IS IN THE RAISED (LOAD) | | | POSITION. | | | | | | 1009.2.7 OPERATION POOL LIFTS MUST BE CAPABLE OF | | | UNASSISTED OPERATION FROM BOTH THE DECK AND WATER | | | LEVELS. THIS WILL PERMIT A PERSON TO CALL THE POOL LIFT | | | WHEN THE POOL LIFT IS IN THE OPPOSITE POSITION. IT IS | | | EXTREMELY IMPORTANT FOR A PERSON WHO IS SWIMMING ALONE | | | TO BE ABLE TO CALL THE POOL LIFT WHEN IT IS IN THE UP | | | POSITION SO HE OR SHE WILL NOT BE STRANDED IN THE WATER | | | FOR EXTENDED PERIODS OF TIME AWAITING ASSISTANCE. THE | | | REQUIREMENT FOR A POOL LIFT TO BE INDEPENDENTLY | | | OPERABLE DOES NOT PRECLUDE ASSISTANCE FROM BEING | | | PROVIDED. | | | | | | 1009.2.8 SUBMERGED DEPTH. OK | | | | | | 1009.2.9 LIFTING CAPACITY. SINGLE PERSON POOL LIFTS | | | MUST BE CAPABLE OF SUPPORTING A MINIMUM WEIGHT OF 300 | | | POUNDS (136 KG) AND SUSTAINING A STATIC LOAD OF AT | | | LEAST ONE AND A HALF TIMES THE RATED LOAD. POOL LIFTS | | | SHOULD BE PROVIDED THAT MEET THE NEEDS OF THE | | | POPULATION THEY SERVE. PROVIDING A POOL LIFT WITH A | | | WEIGHT CAPACITY GREATER THAN 300 POUNDS (136 KG) MAY BE | | | ADVISABLE. | | | | | | 2) COMPLIED SOLAR BLANKET. | | | | | | 3) PUT YOUR PLANS AND SUBMITTALS TOGETHER IN 2 | | | PACKAGES!!!!!!!! WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE ANY VOIDED SHEETS & | | | REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-09-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-09-21 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-09-21 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2015-09-21 10:54:07 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15051022 | | | ADD: 1517 CAMERON SAMUELS LANE | | | CONT: A& G CONCRETE POOLS, INC | | | TEL: ( 772)878-7752 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | | | | | | | NOTICE!!!!!!!!!!!!!!!!!!!!!!!!!: CHAPTER 553.80(2)(B) | | | FLORIDA STATUTES STATES THAT A LOCAL GOVERNMENT SHALL | | | IMPOSE A FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF | | | PLANS ARE REJECTED (3) OR MORE TIMES FOR REPEATED | | | FAILURE TO CORRECT A CODE VIOLATION. | | | | | | | | | | | | 2ND REVIEW | | | DATE: MON. SEPT. 21/2015 | | | ACTION: DENIED | | | | | | 1) 2ND REVIEW ONLY ONE SET OF AQUATIC ACCESS SALES | | | BROCHURE WAS SUBMITTED. COMPLIANCE WITH THE 2010 | | | FBC-ACCESSIBILITY CODE CAN NOT BE DETERMINED PLEASE | | | SHOW COMPLIANCE WITH: | | | 2010 FBC-ACCESSIBILITY COCE; | | | 1009.2.2 SEAT LOCATION | | | 1009.2.4 SEAT HEIGHT | | | 1009.2.5 SEAT WIDTH | | | 1009.2.6 FOOT REST AND ARMREST | | | 1009.2.7 OPERATION | | | 1009.2.8 SUBMERGED DEPTH | | | 1009.2.9 LIFTING CAPACITY | | | | | | 2) 2ND REQUEST. SHEET 1 INDICATES THE USE OF (3) POOL | | | HEATERS. PLEASE PROVIDE CODE COMPLIANCE WITH 2010 | | | FBC-ENERGY CODE 504.7.3 HEATED SWIMMING POOLS AND | | | INGROUND PERMANENTLY INSTALLED SPAS SHALL BE EQUIPED | | | WITH A VAPOR RETARDANT COVER ON THE WATER OR AT THE | | | WATER SURFACE OR A LIQUID COVER OR OTHER MEANS PROVEN | | | TO REDUCE HEAT LOSS. | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-06-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-06 |
Time |
14:15 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2015-06-06 |
Time |
13:30 |
Sent To |
E |
|
| Notes |
| 2015-06-06 14:18:06 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15051022 | | | ADD: 1517 CAMERON SAMUELS LANE | | | CONT: A& G CONCRETE POOLS, INC | | | TEL: ( 772)878-7752 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: SAT. JUNE 06/2015 | | | ACTION: DENIED | | | | | | 1) SHEET 1 INDICATES THE USE OF A BATTERY OPERATED | | | HANDICAPPED CHAIRLIFT. PLEASE PROVIDE THE MANUFACTURERS | | | SPECS ON THIS PRODUCT AND FOR THE INSTALATION OF THE | | | LIFT. 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 2) SHEET 1 INDICATES THE USE OF (3) POOL HEATERS. | | | PLEASE PROVIDE CODE COMPLIANCE WITH 2010 FBC-ENERGY | | | CODE 504.7.3 HEATED SWIMMING POOLS AND INGROUND | | | PERMANENTLY INSTALLED SPAS SHALL BE EQUIPED WITH A | | | VAPOR RETARDANT COVER ON THE WATER OR AT THE WATER | | | SURFACE OR A LIQUID COVER OR OTHER MEANS PROVEN TO | | | REDUCE HEAT LOSS. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2015-11-03 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-11-03 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-11-03 |
Time |
09:49 |
Sent To |
I |
|
| Notes |
| 2015-11-03 10:29:56 | ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN | | | SATISFACTORILY CORRECTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2015-10-23 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-10-23 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-10-23 |
Time |
10:30 |
Sent To |
B |
|
| Notes |
| 2015-10-23 11:11:54 | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE 2008 EDITION | | | OF THE NEC, (NATIONAL ELECTRICAL CODE); THE 2010 | | | EDITION OF THE FBC, (FLORIDA BUILDING CODE) AS | | | APPLICABLE AND BELOW ARE THE DEFICIENCIES NOTED. | | | | | | THE PREVIOUS REVIEW MENTIONED REQUIREMENTS STATED ON | | | THE PLANS INITIALLY SUBMITTED FOR PERMITTING. THESE | | | PLANS THOUGH INCLUDE A GENERIC RISER DIAGRAM AND | | | CONDUCTOR SIZING SCHEDULE, CLEARLY STATE THAT A | | | LICENSED ELECTRICAL CONTRACTOR IS TO PROVIDE ACCURATE | | | LOAD CALCS, FEEDER SCHEDULES, PANEL SCHEDULES AND ALL | | | DATA ASSOCIATED WITH THIS INSTALLATION. FURTHERMORE, AS | | | I INDICATED IN THE PREVIOUS REVIEW COMMENTS, WHAT IS | | | BEING DONE ABOUT THE SITE LIGHTING FOR THIS AREA? IS | | | THE LIGHTING ALREADY IN PLACE? IF SO, INDICATE THAT | | | OTHERWISE SITE LIGHTING DRAWINGS SHALL BE PROVIDED. | | | THESE SHALL COMPLY WITH THE FBC-ENERGY CONSERVATION | | | CODE. THE SCOPE OF THE PERMIT SHALL BE CLEARLY DEFINED | | | TO INCLUDE ALL OF THE PROPOSED WORK. | | | YOU NEED TO SUBMIT SITE PLANS SHOWING THE LOCATION OF | | | THE MAIN DISCONNECT, AND THE LOCATION OF ANY AND ALL | | | EQUIPMENT ASSOCIATED WITH THIS PERMIT. YOU WILL HAVE TO | | | PROVIDE A DIAGRAM OF THE PROPOSED EQUIPMENT RACK IF | | | ANY. SUBMIT LOAD CALCS AND A PANEL SCHEDULE. WHO WILL | | | BE RESPONSIBLE FOR THE EQUI-POTENTIAL BONDING? | | | | | | THE PLANS SHALL BE REVISED TO ADDRESS THE HEREIN | | | MENTIONED ITEMS; ONCE CORRECTED SHALL BE RESUBMITTED | | | FOR ANOTHER REVIEW. WHEN RESUBMITTING, YOU ARE REQUIRED | | | TO PROVIDE A RESPONSE LETTER ADDRESSING EACH ITEM ALONG | | | WITH THE STANDARD CITY RE-SUBMITTAL FORM. PLEASE, | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE SUBMITTAL | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARISON. CLOUDING THE CHANGES WILL BE GREATLY | | | APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-09-17 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-17 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-17 |
Time |
09:07 |
Sent To |
B |
|
| Notes |
| 2015-09-17 11:15:29 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE | | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | | THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE | | | CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW. | | | 1. PER NOTE ON PAGE 5, THE FEED TO THE AQUAWORX PANEL | | | IS BEING PERFORMED BY THE EC (ELECTRICAL CONTRACTOR) | | | UNDER A SEPARATE PERMIT. THAT WOULD EXCLUDE THE | | | EQUIPOTENTIAL BONDING, POOL AND SITE LIGHTING IN | | | ADDITION TO INCIDENTAL ELECTRICAL WORK REQUIRED. | | | ACCORDING TO THE ELECTRICAL DRAWINGS, THE SCOPE | | | TERMINATES AT THE POOL EQUIPMENT DISCONNECT. | | | 2. PROVIDE DETAIL OF AQUAWORX EQUIPMENT WITH LOAD CALCS | | | TO EQUIPMENT DISCONNECT. | | | 3. YOU SHALL INDICATE THE EC FOR THE REMAINDER OF THE | | | WORK AS DESCRIBED ABOVE. | | | 4. AREA LIGHTING SHALL COMPLY WITH THE FBC-E SECTION | | | 505. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-06-08 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-06-08 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-06-08 |
Time |
16:54 |
Sent To |
G |
|
| Notes |
| 2015-06-08 17:03:25 | ACCORDING TO THE SUBMITTED PLANS, THE NOTE ON PAGE 5 OF | | | 5 STATES THAT ELECTRICAL DATA WILL BE SUBMITTED UNDER | | | SEPARATE COVER. PROVIDE ELECTRICAL SPECS AND DRAWINGS | | | OF THE PROPOSED ELECTRICAL WORK FOR THIS POOL ALONG | | | WITH AN EQUIPMENT SPEC SHEET. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2015-06-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-20 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-20 |
Time |
06:49 |
Sent To |
|
|
| Notes |
| 2015-06-20 06:55:00 | 1) GAS TO BE UNDER SEPARATE PERMIT.SEE 15051024 FOR GAS | | | REVIEW COMMENTS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-11-03 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-11-03 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-11-02 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2015-11-03 10:33:32 | 11/3/15 ALL ALL TRADE REVIEWS SUCCESSFULLY AND IS READY | | | TO BE ISSUED. CONTRACTOR NOTIFIED VIA EMAIL. SENT TO | | | LARGE READY BIN "A". MA | | 2015-11-02 13:57:58 | RESUB ROUTED TO MALBARRAN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-10-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-28 |
Time |
06:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-10-13 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2015-10-14 14:53:26 | ROUTED TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-01 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-09-29 |
Time |
09:36 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-09-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-09-21 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-05 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2015-08-05 13:20:21 | RESUB ROUTED TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-06-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-20 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-20 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2015-05-22 11:53:52 | ROUTED TO ZONING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2015-10-22 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-10-22 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-10-22 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-10-01 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-10-01 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2015-10-01 09:29:39 | NONE OF THE PREVIOUS PLUMBING PLAN REVIEW COMMENTS HAVE | | | BEEN ADDRESSED FROM THE REVIEW DONE ON 8/10/15. | | | 1) SHOW THE SPACING BETWEEN THE FLOOR INLETS AND | | | ADJACENT WALL. SPACING SHALL NOT EXCEED 10 FEET PER | | | 2010 FBC SEC.424.1.6.5.9.4. 2ND REQUEST. | | | 2) INDICATE ON THE PLAN HOW WATER WILL BE SUPPLIED TO | | | THE AQUATIC ACCESS LIFT.WPB AMEND. TO FBC SEC. 107.2.1. | | | 3) SHT. 1 OF 5 SHOWS THE POOL WATER DRAINING TO THE | | | SANITARY SYSTEM.POOL WATER CANNOT DRAIN TO THE SANITARY | | | SYSTEM OR TO THE STORM WATER SYSTEM PER CITY ORDINANCE | | | SEC.90-126 (5). PLEASE CONTACT MANNY GONZALEZ IN THE | | | CWPB ENGINEERING DEPT. 561-494-1040 FOR FURTHER | | | DIRECTION. | | | 4) THE POOL HEATERS SHALL COMPLY WITH THE 2010 | | | FBC-ENERGY TABLE 504.2 & SHALL HAVE A THERMAL | | | EFFICIENCY OF 82% AND COMPLY WITH ASHRAE 146. SUBMIT | | | CONFIRMATION OF COMPLIANCE. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2015-08-10 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-10 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-10 |
Time |
05:28 |
Sent To |
|
|
| Notes |
| 2015-08-10 08:49:36 | 1) SHOW THE SPACING BETWEEN THE FLOOR INLETS AND | | | ADJACENT WALL. SPACING SHALL NOT EXCEED 10 FEET PER | | | 2010 FBC SEC.424.1.6.5.9.4. 2ND REQUEST. | | | 2) INDICATE ON THE PLAN HOW WATER WILL BE SUPPLIED TO | | | THE AQUATIC ACCESS LIFT.WPB AMEND. TO FBC SEC. 107.2.1. | | | 3) SHT. 1 OF 5 SHOWS THE POOL WATER DRAINING TO THE | | | SANITARY SYSTEM.POOL WATER CANNOT DRAIN TO THE SANITARY | | | SYSTEM OR TO THE STORM WATER SYSTEM PER CITY ORDINANCE | | | SEC.90-126 (5). PLEASE CONTACT MANNY GONZALEZ IN THE | | | CWPB ENGINEERING DEPT. 561-494-1040 FOR FURTHER | | | DIRECTION. | | | 4) THE POOL HEATERS SHALL COMPLY WITH THE 2010 | | | FBC-ENERGY TABLE 504.2 & SHALL HAVE A THERMAL | | | EFFICIENCY OF 82% AND COMPLY WITH ASHRAE 146. SUBMIT | | | CONFIRMATION OF COMPLIANCE. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-06-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-01 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-01 |
Time |
06:10 |
Sent To |
|
|
| Notes |
| 2015-06-01 14:24:36 | 1) SUBMIT MANUF. SPECS. FOR THE WHEELCHAIR LIFT. WPB | | | AMEND. TO 2010 FBC SEC. 107.2.1. | | | 2) SHT. 1 OF 5 SHOWS THE 3" WASTE LINE DISCHARGING TO | | | THE STORM DRAINAGE SYSTEM.ONLY STORMWATER SHALL DRAIN | | | TO THE STORM DRAINAGE SYSTEM PER CITY ORDINANCE SEC. 90 | | | - 203. | | | 3) SHOW THE SPACING BETWEEN THE FLOOR INLETS AND | | | ADJACENT WALL. SPACING SHALL NOT EXCEED 10 FEET PER | | | 2010 FBC SEC.424.1.6.5.9.4. | | | 4) A BACKFLOW PREVENTION DEVICE SHALL BE INSTALLED AT | | | THE CITY METER.CONTACT STEPHEN HUNTER IN THE CWPB | | | UTILITIES AT 561-822-2242 FOR TYPE OF BFP DEVICE | | | REQUIRED. MINIMUM PROTECTION SHALL BE A REDUCED | | | PRESSURE ZONE (RPZ) TYPE DEVICE. | | | 5) SUBMIT MANUF. SPECS. FOR THE POOL HEATERS. WPB | | | AMEND. TO 2010 FBC SEC. 107.2.1. | | | 6) SUBMIT PIPING DETAILS FOR THE POOL HEATERS. DETAILS | | | SHALL INCLUDE VALVES, THERMOMETER, PIPE SIZES, AND | | | MATERIAL SPECIFICATIONS PER THE 2010 FBC SEC. | | | 424.1.6.5..14. | | | 7) SUBMIT VERIFICATION THAT THE MAXIMUM FILTRATION RATE | | | OF 2 GPM PER SQUARE FOOT OF FILTER AREA IS NOT | | | EXCEEDED. FBC 424.1.6.5.5.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-10-20 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-10-20 |
Time |
09:17 |
Sent To |
B |
|
| Notes |
| 2015-10-20 09:26:05 | 3RD CHECKLIST 10/20/15 ZONING FAILED | | | | | | 1.SUBMIT A COMPLETE SIGNED AND SEALED SITE PLAN OF THE | | | PROPERTY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-08-07 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-08-07 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-08-07 |
Time |
12:14 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-05-27 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-05-27 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-05-27 |
Time |
14:02 |
Sent To |
B |
|
| Notes |
| 2015-05-27 14:07:34 | 5/27/15 ZONING FAILED | | | | | | 1. SUBMIT SIGN AND SEALED SITE PLAN, LANDSCAPE | | | CONCEPTUAL PLAN WILL NOT BE ACCEPTED. |
|
|