Plan Review Details - Permit 15050973
Plan Review Stops For Permit 15050973
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-05-03 Cont ID  
Sent By rmcdouga Date 2016-05-03 Time 17:44 Rev Time 0.00
Received By rmcdouga Date 2016-05-03 Time 06:53 Sent To  
Notes
2016-05-04 08:58:27NOTE: THE NAMING CONVENTION IN PROJECT DOCS FOR THE
 THREE PLAN SHEETS FOR LOT 26 DOES NOT CORRESPOND WITH
 THE PLAN SHEETS THAT WERE UPLOADED. THE SHEET NAMES
 SHOULD HAVE BR IN PLACE OF CR.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-05-03 Cont ID  
Sent By albarran Date 2016-05-03 Time 12:51 Rev Time 0.00
Received By albarran Date 2016-05-03 Time 08:05 Sent To  
Notes
2016-05-06 13:39:32DISREGARD PREVIOUS NOTES BY MALBARRAN
2016-05-03 12:52:35ELECTRICAL REVIEW COMMENTS
  
 MODEL DL, LOT 21 PLANS WERE APPROVED
  
 THIS BEING THE MASTER SET, THE BELOW MENTIONED COMMENTS
 ARE ATTACHED.
  
 FAILED ELECTRICAL REVIEW AS NOTED BELOW.
  
 1. NEC 410.16(B) PROHIBITS THE USE OF THE TRADITIONAL
 PORCELAIN PULL CHAIN FIXTURES IN CLOSETS. USE A
 SUITABLE WALL SWITCHED LUMINAIRE.
 2. NEC 210.70(C) REQUIRES THAT THE SWITCH BE AT THE
 USUAL POINT OF ENTRY.
 3. PAGE 020, ELECTRICAL SHEET FOR LOT 26 A MODEL BR
 UNIT IS MISSING A DUPLICATE OF PAGE 021, THE A2 PAGE
 WAS UPLOADED IN ITS PLACE.
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-06 Cont ID  
Sent By skennedy Date 2016-05-06 Time 13:43 Rev Time 0.00
Received By skennedy Date 2016-04-13 Time 14:35 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-05-06 Cont ID  
Sent By skennedy Date 2016-05-06 Time 13:43 Rev Time 0.00
Received By skennedy Date 2016-05-05 Time 14:28 Sent To  
Notes
2016-05-05 14:28:53RMCDOUGAL'S DESK

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-05-03 Cont ID  
Sent By rmcdouga Date 2016-05-03 Time 08:45 Rev Time 0.00
Received By rmcdouga Date 2016-05-03 Time 08:45 Sent To  
Notes
2016-05-03 08:45:46BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-05-03 Cont ID  
Sent By rmcdouga Date 2016-05-03 Time 17:59 Rev Time 0.00
Received By rmcdouga Date 2016-05-03 Time 17:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-05-02 Cont ID  
Sent By tklarge Date 2016-05-02 Time 09:25 Rev Time 0.00
Received By tklarge Date 2016-05-02 Time 08:26 Sent To  
Notes
2016-05-02 09:29:15SEE #15050973 FOR PLANS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2016-05-11 Cont ID  
Sent By skennedy Date 2016-05-11 Time 12:17 Rev Time 0.00
Received By skennedy Date 2016-05-11 Time 12:17 Sent To  
Notes
2016-05-11 12:17:30ROOFING

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-05-11 Cont ID  
Sent By skennedy Date 2016-05-11 Time 12:16 Rev Time 0.00
Received By skennedy Date 2016-05-11 Time 12:16 Sent To  
Notes
2016-05-11 12:16:41ROOFING

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2016-05-11 Cont ID  
Sent By skennedy Date 2016-05-11 Time 12:06 Rev Time 0.00
Received By skennedy Date 2016-05-11 Time 12:06 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2016-05-06 Cont ID  
Sent By skennedy Date 2016-05-06 Time 13:44 Rev Time 0.00
Received By skennedy Date 2016-05-06 Time 13:44 Sent To  
Notes
2016-05-06 13:45:20SUBMIT ORIGINAL SIGNED AND SEALED SURVEY & TRUSS
 ENGINEERING OR DIGITALLY SIGNED VERSIONS PRIOR TO FIRST
 INSPECTION.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2016-05-04 Cont ID  
Sent By rmcdouga Date 2016-05-04 Time 17:55 Rev Time 0.00
Received By rmcdouga Date 2016-05-04 Time 17:55 Sent To  
Notes
2016-05-04 17:57:27THE TRUSS DRAWINGS AND THE SURVEYS DO NOT HAVE
 ACCEPTABLE ELECTRONIC SIGNATURES.

Review Stop Z ZONING
Rev No 1 Status P Date 2016-05-06 Cont ID  
Sent By llouie Date 2016-05-06 Time   Rev Time  
Received By llouie Date 2016-05-06 Time   Sent To  
Notes
2016-05-06 11:10:41REFERENCE PERMIT #15050973 FOR PLANS.