Plan Review Details - Permit 15050874
| Plan Review Stops For Permit 15050874 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-06-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-12 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-12 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-06-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-02 |
Time |
05:58 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-02 |
Time |
05:55 |
Sent To |
|
|
| Notes |
| 2015-06-02 05:58:49 | 1) SUBMIT DETAILS FOR THE SISTERING OF THE THE FLOOR | | | JOISTS. SHOW THE METHOD OF ATTACHMENT, TYPE OF | | | FASTENERS, CENTER TO CENTER SPACING OF THE | | | CONNECTIONS.WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | | 2) SUBMIT MANUF. SPECS FOR THE TYPE OF STRAPS TO BE | | | USED..WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | | 3) INDICATE THE BEARING LENGTH OF THE FLOOR JOISTS ON | | | THE FOOTERS. .WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | | 4) SUBMIT A FOOTPRINT DRAWING OF THE BUILDING SHOWING | | | THE LOCATIONS OF THE FOOTERS. THE DRAWING CAN BE HAND | | | DRAWN..WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | | 5) SUBMIT PRODUCT APPROVAL REPORTS FOR THE TIE DOWN | | | STRAPS THAT ARE GOING TO BE USED. FL. ADMIN. CODE 9N-3. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-06-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-12 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-11 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2015-06-11 17:52:59 | ROUTED TO TKL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-06-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-02 |
Time |
05:59 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-01 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2015-06-01 11:48:11 | TO PLUMBING | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-06-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-02 |
Time |
05:55 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-02 |
Time |
05:36 |
Sent To |
|
|
| Notes |
|
|
|