Plan Review Details - Permit 15050659
| Plan Review Stops For Permit 15050659 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-07-05 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-07-05 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-06-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-06-03 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-06-03 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2015-06-03 12:08:11 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | | HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND | | | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE | | | CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION | | | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | | HEIGHT: | | | | | | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS | | | - AWNING, CASEMENT, SINGLE HUNG? | | | | | | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. | | | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE | | | WINDOW IS FULLY OPEN. | | | | | | STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE. | | | THIS CAN BE OBTAINED FROM THE MANUFACTURER. | | | | | | 2. PROVIDE AN INFILL DETAIL AND ALSO A FRAMING DETAIL | | | (REMOVAL OF WALL AND DOOR, INSTALLATION OF FRENCH | | | DOORS), FBC 107. | | | | | | 3. REVISE PLAN TO INCLUDE WIND DESIGN CRITERIA FBC 2010 | | | RESIDENTIAL 301 (WIND SPEED, EXPOSURE). | | | | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-05-18 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-05-18 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-05-18 |
Time |
10:43 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-07-05 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-06-16 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2015-06-16 13:38:50 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-06-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-06-03 |
Time |
12:08 |
Rev Time |
|
| Received By |
shill |
Date |
2015-05-18 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-05-19 09:23:23 | SENT TO MISC 1 BOX, WINDOWS AND DOORS. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |