| 2015-08-26 06:26:11 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15050419 | | | ADD: 1009 BANYAN BLVD. | | | CONT: T. B. D. | | | TEL: ( ?????? | | | E-MAIL:????? | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. AUGUST 26/2015 | | | ACTION: DENIED | | | | | | | | | NOTICE: CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES | | | THAT A LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR | | | TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE REJECTED | | | (3) OR MORE TIMES FOR REPEATED FAILURE TO CORRECT A | | | CODE VIOLATION.!!!!!!!!! | | | | | | | | | 1) 2ND REQUEST.THE SOILS REPORT SUBMITTED AS A APPENDIX | | | ATTACHED TO THE JOS SPECIFICATIONS IS NOT A ORIGINAL | | | SIGNED AND SEALED DOCUMENT. PLEASE PROVIDE 2 ORIGINALS. | | | | | | 61G15-23.002(2) FL. ADMIN. CODE. PLANS SIGNED & SEALED | | | BY A PROFESSIONAL ENGINEER SHALL INCLUDE EITHER THE: | | | NAME, ADDRESS AND LICENSE NUMBER OF THE ENGINEER OR, | | | THE NAME AND LICENSE NUMBER OF THE ENGINEER AND THE | | | NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION NUMBER | | | OF THE ENGINEERING BUSINESS THROUGH WHICH THE ENGINEER | | | IS PRACTICING (471.025 F.S. AND 471.023 F.S.). | | | | | | 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR INDEX | | | SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED AND | | | THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF THE | | | PRODUCTION & PREPARATION OF EACH SECTION OF THE | | | ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION | | | ON THE COVER SHEET OR INDEX. | | | | | | 61G15-30.003 ENGINEERING DOCUMENT CLASSIFICATION. | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME AND | | | BUSINESS ADDRESS, ON ENGINEERING DOCUMENTS. ENGINEERING | | | DOCUMENTS WHICH ARE ISSUED FOR PRELIMINARY OR | | | CONCEPTUAL USE, SHALL CLEARLY NOTE THE INTENDED PURPOSE | | | OF SUCH DOCUMENTS. WHEN ELEMENTS OF THE PROJECT ARE | | | SHOWN ON AN ENGINEERING DOCUMENT ONLY FOR INFORMATION | | | OR CLARIFICATION AND THE ENGINEER DOES NOT INTEND TO | | | ACCEPT RESPONSIBILITY FOR THE ELEMENTS, THE ENGINEER | | | SHALL CLEARLY NOTE ON THE DOCUMENTS THE EXTENT OF HIS | | | RESPONSIBILITY. | | | SPECIFIC AUTHORITY 471.033(2), 471.008 FS. LAW | | | IMPLEMENTED 471.033(1)(G), 471.025(3) FS. HISTORY NEW | | | 1-26-93, FORMERLY 21H-30.003. | | | | | | | | | ORIGINAL COMMENT. SHEET GS-1 MISSING THE GEOTECHNICAL | | | REPORT PREPARED BY RESOURCENET INTERNATIONAL, INC | | | PROJECT NUMBER : 1409. REVIEW 2010 FBC-B 1803.5.2 | | | QUESTIONABLE SOIL. | | | | | | 2-3) COMPLIED | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-05-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-05-16 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-13 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2015-05-16 10:00:40 | | | | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15050419 | | | ADD: 1009 BANYAN BLVD. | | | CONT: T. B. D. | | | TEL: ( ?????? | | | E-MAIL:????? | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: SAT. MAY 16/2015 | | | ACTION: DENIED | | | | | | 1) SHEET GS-1 MISSING THE GEOTECHNICAL REPORT PREPARED | | | BY RESOURCENET INTERNATIONAL, INC PROJECT NUMBER : | | | 1409. REVIEW 2010 FBC-B 1803.5.2 QUESTIONABLE SOIL. | | | | | | 2) SHEET GS-1 WIND DESIGN CRITERIA: THE EXPOSURE IS | | | INDICATED AS A EXPOSURE B. TO THE WEST IS LAKE | | | MANGONIA. 2010 FBC-B SURFACE ROUGHNESS C. OPEN TERRAIN | | | WITH SCATTERED OBSTRUCTIONS HAVING HEIGHTS GENERALLY | | | LESS THAN 30 FEET (9144 MM). THIS CATEGORY INCLUDES | | | FLAT OPEN COUNTRY AND GRASSLANDS.THIS SURFACE ROUGHNESS | | | SHALL ALSO APPLY TO ANY BUILDING LOCATED WITHIN SURFACE | | | ROUGHNESS B-TYPE TERRAIN WHERE THE BUILDING IS WITHIN | | | 100 FEET HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF | | | SURFACE ROUGHNESS C OR D-TYPE TERRAIN THAT EXTENDS MORE | | | THAN 600 FEET (182.9 M) AND WIDTH GREATER THAN 150 FEET | | | IN THE UPWIND DIRECTION. SHORT-TERM (LESS THAN TWO | | | YEAR) CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE, FOR | | | THE PURPOSES OF DEVELOPMENT, SHALL NOT BE CONSIDERED | | | SURFACE ROUGHNESS C. WHERE DEVELOPMENT BUILDOUT WILL | | | OCCUR WITHIN THREE YEARS AND THE RESULTANT CONDITION | | | WILL MEET THE DEFINITION OF SURFACE ROUGHNESS B, | | | SURFACE ROUGHNESS B SHALL BE REGULATING FOR THE PURPOSE | | | OF PERMITTING. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY | | | AND GRASSLANDS AND SHALL EXTEND DOWNWIND FOR A DISTANCE | | | OF 1500 FEET. | | | | | | 3A) SHEET GS-5 & 16S-8 BOTH SHOW GUARDRAIL SYSTEMS | | | PLEASE SHOW COMPLIANCE WITH: 2010 FBC-B 1013.2 REQUIRED | | | GUARDS SHALL BE NOT LESS THAN 42 INCHES (1067 MM) HIGH, | | | MEASURED VERTICALLY ABOVE THE ADJACENT WALKING | | | SURFACES, ADJACENT FIXED SEATING OR THE LINE CONNECTING | | | THE LEADING EDGES OF THE TREADS. | | | | | | 3B) PROVIDE COMPLIANCE WITH: 2010 FBC-B 1013.3 OPENING | | | LIMITATIONS. EXCEPTION (3). AT ELEVATED WALKING | | | SURFACES FOR ACCESS TO AND USE OF ELECTRICAL, | | | MECHANICAL OR PLUMBING SYSTEMS OR EQUIPMENT, GUARDS | | | SHALL NOT HAVE OPENINGS WHICH ALLOW PASSAGE OF A SPHERE | | | 21 INCHES (533 MM) IN DIAMETER. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-08-31 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-08-31 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-06-15 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-06-15 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-06-15 |
Time |
13:26 |
Sent To |
I |
|
| Notes |
| 2015-06-15 13:38:42 | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | ELECTRONIC MEDIA DOCUMENTS SHALL BE | | | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2015-09-01 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-09-01 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-09-01 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2015-05-22 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-05-22 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-05-21 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2015-05-22 07:40:48 | THE SUBMITTED DESIGN PLANS WERE NOT SIGNED OR SEALED BY | | | A LICENSED PROFESSIONAL (ARCHITECT, CIVIL ENGINEER, | | | AND/OR LANDSCAPE ARCHITECT). PLEASE SUBMIT SIGNED AND | | | SEALED PLANS. (FAC 61G15-23.002, FS 481.221 AND | | | 481.321) | | | | | | KELLY CRANFORD, P.E. | | | LAND DEVELOPMENT ENGINEER | | | PUBLIC WORKS DEPARTMENT | | | CITY OF WEST PALM BEACH | | | [email protected] | | | 561-494-1098 (OFFICE) |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-08-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-08-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-08-21 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2015-08-21 10:30:35 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | RESTATED: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | 1) PROVIDE 10LB ABC FIRE EXTINGUISHER TO PROTECT | | | EQUIPMENT WHERE APPROPRIATE. PROVIDE CLASS "C" ONLY | | | WHERE APPROPRIATE. | | | | | | 2) RAILING GUARDS SHALL NOT BE LESS THAN 42" ABOVE | | | FINISHED FLOOR. NFPA 7.2.2.4.5 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-05-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-05-15 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2015-05-15 16:26:16 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | 1) PROVIDE 10LB ABC FIRE EXTINGUISHER TO PROTECT | | | EQUIPMENT WHERE APPROPRIATE. PROVIDE CLASS "C" ONLY | | | WHERE APPROPRIATE. | | | | | | 2) RAILING GUARDS SHALL NOT BE LESS THAN 42" ABOVE | | | FINISHED FLOOR. NFPA 7.2.2.4.5 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-09-01 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-09-01 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-08-11 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-06-15 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-06-15 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-05-12 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2015-06-15 13:41:43 | DUE TO LACK OF CONTACT INFO ON PERMIT APP. THIS WAS | | | SENT TO SMALL DENIED BIN "W" | | 2015-05-13 09:56:46 | SENT TO C7 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2015-06-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-06-08 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-06-08 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2015-06-08 11:44:48 | ADDED PLUMBING STOP PER MR. LARGE- THIS IS A PLUMBING | | | REVIEW FOR PAC WATER TREATMENT SYSTEMS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-08-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-17 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-17 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-06-15 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-15 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-15 |
Time |
05:44 |
Sent To |
|
|
| Notes |
| 2015-06-15 07:52:44 | 1) PLANS SHALL BE SSIGNED AND SEALED BY AN ENGINEER PER | | | THE CITY OF WPB AMEND. TO THE 2010 FBC SEC.105.3.1.2 | | | (1), F.S. 471, & 61G15-23.002. | | | 2) PLANS SHALL BE DRAWN TO A MINIMUM OF A 1/8" SCALE | | | PER CITY OF WPB AMEND. TO 2010 FBC SEC.107.2.1.4. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-08-28 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-08-28 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-08-27 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-06-04 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-06-04 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-06-04 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|