Plan Review Details - Permit 15050419
Plan Review Stops For Permit 15050419
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-08-31 Cont ID  
Sent By jwitmer Date 2015-08-31 Time 14:56 Rev Time 0.00
Received By jwitmer Date 2015-08-31 Time 14:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-08-26 Cont ID  
Sent By jwitmer Date 2015-08-26 Time 06:26 Rev Time 0.00
Received By jwitmer Date 2015-08-26 Time 05:58 Sent To  
Notes
2015-08-26 06:26:11BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15050419
 ADD: 1009 BANYAN BLVD.
 CONT: T. B. D.
 TEL: ( ??????
 E-MAIL:?????
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. AUGUST 26/2015
 ACTION: DENIED
  
  
 NOTICE: CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES
 THAT A LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR
 TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE REJECTED
 (3) OR MORE TIMES FOR REPEATED FAILURE TO CORRECT A
 CODE VIOLATION.!!!!!!!!!
  
  
 1) 2ND REQUEST.THE SOILS REPORT SUBMITTED AS A APPENDIX
 ATTACHED TO THE JOS SPECIFICATIONS IS NOT A ORIGINAL
 SIGNED AND SEALED DOCUMENT. PLEASE PROVIDE 2 ORIGINALS.
  
 61G15-23.002(2) FL. ADMIN. CODE. PLANS SIGNED & SEALED
 BY A PROFESSIONAL ENGINEER SHALL INCLUDE EITHER THE:
 NAME, ADDRESS AND LICENSE NUMBER OF THE ENGINEER OR,
 THE NAME AND LICENSE NUMBER OF THE ENGINEER AND THE
 NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION NUMBER
 OF THE ENGINEERING BUSINESS THROUGH WHICH THE ENGINEER
 IS PRACTICING (471.025 F.S. AND 471.023 F.S.).
  
 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR INDEX
 SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED AND
 THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF THE
 PRODUCTION & PREPARATION OF EACH SECTION OF THE
 ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION
 ON THE COVER SHEET OR INDEX.
  
 61G15-30.003 ENGINEERING DOCUMENT CLASSIFICATION.
 ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME AND
 BUSINESS ADDRESS, ON ENGINEERING DOCUMENTS. ENGINEERING
 DOCUMENTS WHICH ARE ISSUED FOR PRELIMINARY OR
 CONCEPTUAL USE, SHALL CLEARLY NOTE THE INTENDED PURPOSE
 OF SUCH DOCUMENTS. WHEN ELEMENTS OF THE PROJECT ARE
 SHOWN ON AN ENGINEERING DOCUMENT ONLY FOR INFORMATION
 OR CLARIFICATION AND THE ENGINEER DOES NOT INTEND TO
 ACCEPT RESPONSIBILITY FOR THE ELEMENTS, THE ENGINEER
 SHALL CLEARLY NOTE ON THE DOCUMENTS THE EXTENT OF HIS
 RESPONSIBILITY.
 SPECIFIC AUTHORITY 471.033(2), 471.008 FS. LAW
 IMPLEMENTED 471.033(1)(G), 471.025(3) FS. HISTORY NEW
 1-26-93, FORMERLY 21H-30.003.
  
  
 ORIGINAL COMMENT. SHEET GS-1 MISSING THE GEOTECHNICAL
 REPORT PREPARED BY RESOURCENET INTERNATIONAL, INC
 PROJECT NUMBER : 1409. REVIEW 2010 FBC-B 1803.5.2
 QUESTIONABLE SOIL.
  
 2-3) COMPLIED
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-05-16 Cont ID  
Sent By jwitmer Date 2015-05-16 Time 10:00 Rev Time 0.00
Received By tklarge Date 2015-06-13 Time 09:12 Sent To  
Notes
2015-05-16 10:00:40 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15050419
 ADD: 1009 BANYAN BLVD.
 CONT: T. B. D.
 TEL: ( ??????
 E-MAIL:?????
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. MAY 16/2015
 ACTION: DENIED
  
 1) SHEET GS-1 MISSING THE GEOTECHNICAL REPORT PREPARED
 BY RESOURCENET INTERNATIONAL, INC PROJECT NUMBER :
 1409. REVIEW 2010 FBC-B 1803.5.2 QUESTIONABLE SOIL.
  
 2) SHEET GS-1 WIND DESIGN CRITERIA: THE EXPOSURE IS
 INDICATED AS A EXPOSURE B. TO THE WEST IS LAKE
 MANGONIA. 2010 FBC-B SURFACE ROUGHNESS C. OPEN TERRAIN
 WITH SCATTERED OBSTRUCTIONS HAVING HEIGHTS GENERALLY
 LESS THAN 30 FEET (9144 MM). THIS CATEGORY INCLUDES
 FLAT OPEN COUNTRY AND GRASSLANDS.THIS SURFACE ROUGHNESS
 SHALL ALSO APPLY TO ANY BUILDING LOCATED WITHIN SURFACE
 ROUGHNESS B-TYPE TERRAIN WHERE THE BUILDING IS WITHIN
 100 FEET HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF
 SURFACE ROUGHNESS C OR D-TYPE TERRAIN THAT EXTENDS MORE
 THAN 600 FEET (182.9 M) AND WIDTH GREATER THAN 150 FEET
 IN THE UPWIND DIRECTION. SHORT-TERM (LESS THAN TWO
 YEAR) CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE, FOR
 THE PURPOSES OF DEVELOPMENT, SHALL NOT BE CONSIDERED
 SURFACE ROUGHNESS C. WHERE DEVELOPMENT BUILDOUT WILL
 OCCUR WITHIN THREE YEARS AND THE RESULTANT CONDITION
 WILL MEET THE DEFINITION OF SURFACE ROUGHNESS B,
 SURFACE ROUGHNESS B SHALL BE REGULATING FOR THE PURPOSE
 OF PERMITTING. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY
 AND GRASSLANDS AND SHALL EXTEND DOWNWIND FOR A DISTANCE
 OF 1500 FEET.
  
 3A) SHEET GS-5 & 16S-8 BOTH SHOW GUARDRAIL SYSTEMS
 PLEASE SHOW COMPLIANCE WITH: 2010 FBC-B 1013.2 REQUIRED
 GUARDS SHALL BE NOT LESS THAN 42 INCHES (1067 MM) HIGH,
 MEASURED VERTICALLY ABOVE THE ADJACENT WALKING
 SURFACES, ADJACENT FIXED SEATING OR THE LINE CONNECTING
 THE LEADING EDGES OF THE TREADS.
  
 3B) PROVIDE COMPLIANCE WITH: 2010 FBC-B 1013.3 OPENING
 LIMITATIONS. EXCEPTION (3). AT ELEVATED WALKING
 SURFACES FOR ACCESS TO AND USE OF ELECTRICAL,
 MECHANICAL OR PLUMBING SYSTEMS OR EQUIPMENT, GUARDS
 SHALL NOT HAVE OPENINGS WHICH ALLOW PASSAGE OF A SPHERE
 21 INCHES (533 MM) IN DIAMETER.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-08-31 Cont ID  
Sent By albarran Date 2015-08-31 Time 16:24 Rev Time 0.00
Received By albarran Date 2015-08-31 Time 15:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-06-15 Cont ID  
Sent By albarran Date 2015-06-15 Time 13:34 Rev Time 0.00
Received By albarran Date 2015-06-15 Time 13:26 Sent To I
Notes
2015-06-15 13:38:42107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 ELECTRONIC MEDIA DOCUMENTS SHALL BE
 SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2015-09-01 Cont ID  
Sent By cranford Date 2015-09-01 Time 15:21 Rev Time 0.00
Received By cranford Date 2015-09-01 Time 15:21 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2015-05-22 Cont ID  
Sent By cranford Date 2015-05-22 Time 07:40 Rev Time 0.00
Received By cranford Date 2015-05-21 Time 12:44 Sent To  
Notes
2015-05-22 07:40:48THE SUBMITTED DESIGN PLANS WERE NOT SIGNED OR SEALED BY
 A LICENSED PROFESSIONAL (ARCHITECT, CIVIL ENGINEER,
 AND/OR LANDSCAPE ARCHITECT). PLEASE SUBMIT SIGNED AND
 SEALED PLANS. (FAC 61G15-23.002, FS 481.221 AND
 481.321)
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-08-21 Cont ID  
Sent By pleduc Date 2015-08-21 Time   Rev Time 0.00
Received By pleduc Date 2015-08-21 Time 10:23 Sent To  
Notes
2015-08-21 10:30:35THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 RESTATED:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 1) PROVIDE 10LB ABC FIRE EXTINGUISHER TO PROTECT
 EQUIPMENT WHERE APPROPRIATE. PROVIDE CLASS "C" ONLY
 WHERE APPROPRIATE.
  
 2) RAILING GUARDS SHALL NOT BE LESS THAN 42" ABOVE
 FINISHED FLOOR. NFPA 7.2.2.4.5
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-05-19 Cont ID  
Sent By pleduc Date 2015-05-15 Time   Rev Time 0.00
Received By pleduc Date 2015-05-15 Time 15:32 Sent To  
Notes
2015-05-15 16:26:16THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 1) PROVIDE 10LB ABC FIRE EXTINGUISHER TO PROTECT
 EQUIPMENT WHERE APPROPRIATE. PROVIDE CLASS "C" ONLY
 WHERE APPROPRIATE.
  
 2) RAILING GUARDS SHALL NOT BE LESS THAN 42" ABOVE
 FINISHED FLOOR. NFPA 7.2.2.4.5
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-09-01 Cont ID  
Sent By cranford Date 2015-09-01 Time 15:22 Rev Time 0.00
Received By cranford Date 2015-08-11 Time 10:12 Sent To  
Notes
2015-08-11 10:18:51C09

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-06-15 Cont ID  
Sent By albarran Date 2015-06-15 Time 13:40 Rev Time 0.00
Received By albarran Date 2015-05-12 Time 09:53 Sent To  
Notes
2015-06-15 13:41:43DUE TO LACK OF CONTACT INFO ON PERMIT APP. THIS WAS
 SENT TO SMALL DENIED BIN "W"
2015-05-13 09:56:46SENT TO C7 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2015-06-08 Cont ID  
Sent By ccole Date 2015-06-08 Time 11:41 Rev Time 0.00
Received By ccole Date 2015-06-08 Time 11:41 Sent To  
Notes
2015-06-08 11:44:48ADDED PLUMBING STOP PER MR. LARGE- THIS IS A PLUMBING
 REVIEW FOR PAC WATER TREATMENT SYSTEMS

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-08-17 Cont ID  
Sent By tklarge Date 2015-08-17 Time 11:16 Rev Time 0.00
Received By tklarge Date 2015-08-17 Time 11:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-06-15 Cont ID  
Sent By tklarge Date 2015-06-15 Time 07:53 Rev Time 0.00
Received By tklarge Date 2015-06-15 Time 05:44 Sent To  
Notes
2015-06-15 07:52:441) PLANS SHALL BE SSIGNED AND SEALED BY AN ENGINEER PER
 THE CITY OF WPB AMEND. TO THE 2010 FBC SEC.105.3.1.2
 (1), F.S. 471, & 61G15-23.002.
 2) PLANS SHALL BE DRAWN TO A MINIMUM OF A 1/8" SCALE
 PER CITY OF WPB AMEND. TO 2010 FBC SEC.107.2.1.4.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2015-08-28 Cont ID  
Sent By jroach Date 2015-08-28 Time 10:40 Rev Time 0.00
Received By jroach Date 2015-08-27 Time 16:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-06-04 Cont ID  
Sent By jroach Date 2015-06-04 Time 14:02 Rev Time 0.00
Received By jroach Date 2015-06-04 Time 14:02 Sent To  
Notes
***NONE***