| Plan Review Stops For Permit 15050397 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-10-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-06 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-06 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-07-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-16 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-13 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2015-07-16 08:10:13 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE SEAL THAT THE ENGINEER JOHN D. HOLT USED ON THE | | | PLANS IS NO LONGER ACCEPTABLE TO THE FLORIDA BOARD OF | | | ENGINEERS. THE SEAL IS REQUIRED TO HAVE THE WORD | | | LICENSE IN LIEU OF THE WORD CERTIFICATE. FAC | | | 61G15-23.001 | | | | | | 2) SUBMIT TWO SETS OF A SITE DRAINAGE PLAN THAT SHOWS | | | COMPLIANCE WITH FBC-R401.3. | | | | | | 3) THE NOTE ON SHEET 2 STATES THAT EXTERIOR FOOTERS AT | | | FINISH SLABS ARE TO BE 3" CLEAR FROM GRADE. | | | FBC-R404.1.6 REQUIRES THE CONCRETE FOUNDATION WALLS TO | | | EXTEND A MINIMUM OF 4" ABOVE FINISHED GRADE. | | | | | | 4) SHEET 3.0 WHICH IS THE PLUMBING RISER PLAN IS | | | MISSING FROM THE PLANS, BUT IS LISTED IN THE DRAWING | | | INDEX ON THE COVERSHEET. FBC 107.2.1 | | | | | | 5) TWO DIFFERENT ROOFING PRODUCT APPROVALS FOR TILE | | | WERE SUBMITTED (NOA NO.12-1004.01 & 12-0904.18) AND | | | NEITHER OF THEM WERE APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD AS REQUIRED BY FBC 107.3.4.1 | | | | | | 6) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED | | | TO INSTALL THE ROOF TILES AND MEET THE REQUIRED | | | OVERTURN MOMENT. CIRCLE THE SELECTED FASTENER ON THE | | | PRODUCT APPROVAL DOCUMENTS. IF AN ADHESIVE IS USED, | | | SUBMIT TWO COPIES OF IT'S PRODUCT APPROVALS THAT HAVE | | | BEEN APPROVED IN WRITING BY THE DESIGNER OF RECORD. FBC | | | 107.2.1 AND FBC-R301.2.1 | | | | | | 7) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE | | | EXTERIOR DOORS THAT ARE 8 FEET IN HEIGHT. ALL OF THE | | | DOORS LISTED IN THE SCHEDULE ON SHEET 4 ARE 96" (8 FT) | | | IN HEIGHT, EXCEPT DOOR #3 WHICH IS 80" (6' 8") IN | | | HEIGHT. FBC 107.2.1 AND FBC-R301.2.1 BOTH OF THE | | | OUTSWING DOOR PRODUCT APPROVALS ARE FOR 6' 8" TALL | | | DOORS. | | | | | | 8) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD FOR THE STRUCTURAL MULLIONS. PROVIDE | | | TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS | | | INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN | | | PRESSURES. | | | | | | 9) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | | SINGLE HUNG WINDOWS ARE DEFICIENT. THE FL# IS NOT | | | PROVIDED IN THE DOCUMENTS AND THE MAXIMUM NEGATIVE | | | DESIGN PRESSURE (-60 PSF) IS NOT ADEQUATE FOR ALL OF | | | THE WINDOWS LISTED IN THE SCHEDULE ON SHEET 4. | | | FBC-R301.2.1 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-10-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-06 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-06 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-13 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-13 |
Time |
19:00 |
Sent To |
|
|
| Notes |
| 2015-07-13 19:01:10 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | | | | FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-20 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-19 |
Time |
17:32 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-10-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-06 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-09-29 |
Time |
15:46 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-07-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-05-12 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2015-05-13 11:16:13 | SENT TO R25 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2015-10-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-21 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-21 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2015-10-21 16:54:18 | MU 2015 - 25044 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-20 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-20 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2015-10-20 17:22:45 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-10-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-06 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-06 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2015-10-06 11:10:28 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-13 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-13 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2015-07-13 16:44:35 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-20 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-20 |
Time |
17:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-10-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-06 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-10-06 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2015-10-06 10:22:15 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. THE SIGNATURE OF | | | THE SYSTEM DESIGNER IS REQUIRED ON THE MECHANICAL | | | PLANS. FS 471.003 (2)(H) | | | | | | 2) FBC-R - M 1602.4 BALANCED AIR RETURN. THE 10" | | | TRANSFER DUCT FROM THE MASTER BEDROOM SUITE IS TOO | | | SMALL. THE DIAMETER OF THE SUPPLY AIR DUCTS ENTERING | | | THE MASTER SUITE IS 64 SQ.IN. WHICH REQUIRES A 12 | | | SQ.IN. DIAMETER TRANSFER DUCT. | | | | | | 3) FBC-R 1602.2 PROHIBITED SOURCES. RETURN AIR FOR A | | | FORCED-AIR HEATING OR COOLING SYSTEM SHALL NOT BE TAKEN | | | FROM A KITCHEN. | | | | | | 4) THE SIZE OF THE RETURN AIR GRILL IS NOT SPECIFIED ON | | | THE PLANS. FBC 107.2.1 | | | | | | 5) THE CFMS IN THE MASTER CLOSET AND BATH ROOM #2 IS | | | SPECIFIED ON THE PLANS AS 3 CFMS. IS THIS CORRECT ? FBC | | | 107.2.1 | | | | | | 6) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-07-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-16 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-16 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2015-07-16 10:36:52 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. THE NAME, | | | SIGNATURE AND LICENSE NUMBER IS REQUIRED ON THE | | | MECHANICAL PLANS. FS 471.003 (2)(H) | | | | | | 2) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | | EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS | | | CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER | | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. | | | PROVIDE EQUIPMENT SIZING CALCULATIONS. THE EQUIPMENT | | | SCHEDULE ON THE MECHANICAL PLANS ARE REQUIRED TO MATCH | | | THE SIZING CALCULATIONS. | | | | | | 3) FBC-R M1507.2 EXHAUST AIR FROM BATHROOMS SHALL BE | | | EXHAUSTED DIRECTLY TO THE OUTDOORS. | | | | | | 4) THE ENERGY COMPLIANCE REPORT FORM 405-10, WHICH WAS | | | SUBMITTED, IS REQUIRED TO BE SIGNED AND DATED BY THE | | | PREPARER AND THE OWNER/AGENT. FBC ENERGY 405.4.2 | | | | | | 5) THE R-VALUE FOR THE EXTERIOR CONCRETE BLOCK WALL | | | INSULATION IS LISTED ON THE COMPLIANCE FORM AS R-5 AND | | | THE WALL SECTION ON SHEET 10 HAS R-4.2. PLEASE CORRECT. | | | | | | 6) THERE IS ANOTHER R-VALUE FOR THE EXTERIOR CONCRETE | | | BLOCK WALL INSULATION LISTED ON THE COMPLIANCE FORM AS | | | R-13. IT APPEARS THAT THIS IS MEANT TO BE THE R-VALUE | | | OF THE WOOD FRAME WALL BETWEEN THE GARAGE AND THE | | | LIVING SPACE. PLEASE CORRECT. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-10-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-10-01 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-10-01 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-06-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-12 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-12 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2015-06-12 13:53:18 | SUBMIT A SANITARY PLUMBING RISER DIAGRAM FOR REVIEW PER | | | WPB AMEND. TO 2010 FBC SEC. 107.3.5.3. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2015-10-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-13 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-13 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2015-07-13 16:46:43 | ENTEGRA ESTATE 'S' TILE, NOA NO.14-1120.08 | | | 3M, AH-160 FOAM ROOF TILE ADHESIVE, NOA NO.13-0502.02 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-09-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-10-06 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-05-19 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-05-19 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2015-05-19 16:07:33 | 5/19/15 ZONING FAILED | | | | | | 1. SIDE SETBACK IS A TOTAL OF 15' BETWEEN THE TWO SIDE | | | YARDS, YOU WOULD NEED 5' AND 10' NOT 5' AND 9'. |
|
|