Plan Review Details - Permit 15050397
Plan Review Stops For Permit 15050397
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-10-06 Cont ID  
Sent By rmcdouga Date 2015-10-06 Time 15:32 Rev Time 0.00
Received By rmcdouga Date 2015-10-06 Time 07:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-07-16 Cont ID  
Sent By rmcdouga Date 2015-07-16 Time 10:07 Rev Time 0.00
Received By rmcdouga Date 2015-07-13 Time 15:57 Sent To  
Notes
2015-07-16 08:10:13PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE SEAL THAT THE ENGINEER JOHN D. HOLT USED ON THE
 PLANS IS NO LONGER ACCEPTABLE TO THE FLORIDA BOARD OF
 ENGINEERS. THE SEAL IS REQUIRED TO HAVE THE WORD
 LICENSE IN LIEU OF THE WORD CERTIFICATE. FAC
 61G15-23.001
  
 2) SUBMIT TWO SETS OF A SITE DRAINAGE PLAN THAT SHOWS
 COMPLIANCE WITH FBC-R401.3.
  
 3) THE NOTE ON SHEET 2 STATES THAT EXTERIOR FOOTERS AT
 FINISH SLABS ARE TO BE 3" CLEAR FROM GRADE.
 FBC-R404.1.6 REQUIRES THE CONCRETE FOUNDATION WALLS TO
 EXTEND A MINIMUM OF 4" ABOVE FINISHED GRADE.
  
 4) SHEET 3.0 WHICH IS THE PLUMBING RISER PLAN IS
 MISSING FROM THE PLANS, BUT IS LISTED IN THE DRAWING
 INDEX ON THE COVERSHEET. FBC 107.2.1
  
 5) TWO DIFFERENT ROOFING PRODUCT APPROVALS FOR TILE
 WERE SUBMITTED (NOA NO.12-1004.01 & 12-0904.18) AND
 NEITHER OF THEM WERE APPROVED IN WRITING BY THE
 DESIGNER OF RECORD AS REQUIRED BY FBC 107.3.4.1
  
 6) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED
 TO INSTALL THE ROOF TILES AND MEET THE REQUIRED
 OVERTURN MOMENT. CIRCLE THE SELECTED FASTENER ON THE
 PRODUCT APPROVAL DOCUMENTS. IF AN ADHESIVE IS USED,
 SUBMIT TWO COPIES OF IT'S PRODUCT APPROVALS THAT HAVE
 BEEN APPROVED IN WRITING BY THE DESIGNER OF RECORD. FBC
 107.2.1 AND FBC-R301.2.1
  
 7) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE
 EXTERIOR DOORS THAT ARE 8 FEET IN HEIGHT. ALL OF THE
 DOORS LISTED IN THE SCHEDULE ON SHEET 4 ARE 96" (8 FT)
 IN HEIGHT, EXCEPT DOOR #3 WHICH IS 80" (6' 8") IN
 HEIGHT. FBC 107.2.1 AND FBC-R301.2.1 BOTH OF THE
 OUTSWING DOOR PRODUCT APPROVALS ARE FOR 6' 8" TALL
 DOORS.
  
 8) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD FOR THE STRUCTURAL MULLIONS. PROVIDE
 TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS
 INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN
 PRESSURES.
  
 9) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 SINGLE HUNG WINDOWS ARE DEFICIENT. THE FL# IS NOT
 PROVIDED IN THE DOCUMENTS AND THE MAXIMUM NEGATIVE
 DESIGN PRESSURE (-60 PSF) IS NOT ADEQUATE FOR ALL OF
 THE WINDOWS LISTED IN THE SCHEDULE ON SHEET 4.
 FBC-R301.2.1
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-10-06 Cont ID  
Sent By rmcdouga Date 2015-10-06 Time 11:26 Rev Time 0.00
Received By rmcdouga Date 2015-10-06 Time 07:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-07-13 Cont ID  
Sent By rmcdouga Date 2015-07-13 Time 19:00 Rev Time 0.00
Received By rmcdouga Date 2015-07-13 Time 19:00 Sent To  
Notes
2015-07-13 19:01:10PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
  
 FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS.
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-10-20 Cont ID  
Sent By rmcdouga Date 2015-10-20 Time 18:33 Rev Time 0.00
Received By rmcdouga Date 2015-10-19 Time 17:32 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-10-06 Cont ID  
Sent By rmcdouga Date 2015-10-06 Time 15:32 Rev Time 0.00
Received By rmcdouga Date 2015-09-29 Time 15:46 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2015-07-16 Time   Rev Time 0.00
Received By jgomez Date 2015-05-12 Time 11:15 Sent To  
Notes
2015-05-13 11:16:13SENT TO R25 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2015-10-21 Cont ID  
Sent By rmcdouga Date 2015-10-21 Time 16:54 Rev Time 0.00
Received By rmcdouga Date 2015-10-21 Time 16:49 Sent To  
Notes
2015-10-21 16:54:18MU 2015 - 25044

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2015-10-20 Cont ID  
Sent By rmcdouga Date 2015-10-20 Time 17:22 Rev Time 0.00
Received By rmcdouga Date 2015-10-20 Time 17:22 Sent To  
Notes
2015-10-20 17:22:45BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-10-06 Cont ID  
Sent By rmcdouga Date 2015-10-06 Time 11:10 Rev Time 0.00
Received By rmcdouga Date 2015-10-06 Time 07:10 Sent To  
Notes
2015-10-06 11:10:28BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-07-13 Cont ID  
Sent By rmcdouga Date 2015-07-13 Time 16:43 Rev Time 0.00
Received By rmcdouga Date 2015-07-13 Time 16:43 Sent To  
Notes
2015-07-13 16:44:35BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-10-20 Cont ID  
Sent By rmcdouga Date 2015-10-20 Time 18:33 Rev Time 0.00
Received By rmcdouga Date 2015-10-20 Time 17:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-10-06 Cont ID  
Sent By rmcdouga Date 2015-10-06 Time 10:22 Rev Time 0.00
Received By rmcdouga Date 2015-10-06 Time 07:10 Sent To  
Notes
2015-10-06 10:22:15PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS.
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN. THE SIGNATURE OF
 THE SYSTEM DESIGNER IS REQUIRED ON THE MECHANICAL
 PLANS. FS 471.003 (2)(H)
  
 2) FBC-R - M 1602.4 BALANCED AIR RETURN. THE 10"
 TRANSFER DUCT FROM THE MASTER BEDROOM SUITE IS TOO
 SMALL. THE DIAMETER OF THE SUPPLY AIR DUCTS ENTERING
 THE MASTER SUITE IS 64 SQ.IN. WHICH REQUIRES A 12
 SQ.IN. DIAMETER TRANSFER DUCT.
  
 3) FBC-R 1602.2 PROHIBITED SOURCES. RETURN AIR FOR A
 FORCED-AIR HEATING OR COOLING SYSTEM SHALL NOT BE TAKEN
 FROM A KITCHEN.
  
 4) THE SIZE OF THE RETURN AIR GRILL IS NOT SPECIFIED ON
 THE PLANS. FBC 107.2.1
  
 5) THE CFMS IN THE MASTER CLOSET AND BATH ROOM #2 IS
 SPECIFIED ON THE PLANS AS 3 CFMS. IS THIS CORRECT ? FBC
 107.2.1
  
 6) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE
 CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER
 INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN
 ADDRESSED.
  
  
  
  
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-07-16 Cont ID  
Sent By rmcdouga Date 2015-07-16 Time 11:45 Rev Time 0.00
Received By rmcdouga Date 2015-07-16 Time 10:07 Sent To  
Notes
2015-07-16 10:36:52PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS.
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN. THE NAME,
 SIGNATURE AND LICENSE NUMBER IS REQUIRED ON THE
 MECHANICAL PLANS. FS 471.003 (2)(H)
  
 2) FBC-R - M1401.3 SIZING. HEATING AND COOLING
 EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS
 CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER
 APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES.
 PROVIDE EQUIPMENT SIZING CALCULATIONS. THE EQUIPMENT
 SCHEDULE ON THE MECHANICAL PLANS ARE REQUIRED TO MATCH
 THE SIZING CALCULATIONS.
  
 3) FBC-R M1507.2 EXHAUST AIR FROM BATHROOMS SHALL BE
 EXHAUSTED DIRECTLY TO THE OUTDOORS.
  
 4) THE ENERGY COMPLIANCE REPORT FORM 405-10, WHICH WAS
 SUBMITTED, IS REQUIRED TO BE SIGNED AND DATED BY THE
 PREPARER AND THE OWNER/AGENT. FBC ENERGY 405.4.2
  
 5) THE R-VALUE FOR THE EXTERIOR CONCRETE BLOCK WALL
 INSULATION IS LISTED ON THE COMPLIANCE FORM AS R-5 AND
 THE WALL SECTION ON SHEET 10 HAS R-4.2. PLEASE CORRECT.
  
 6) THERE IS ANOTHER R-VALUE FOR THE EXTERIOR CONCRETE
 BLOCK WALL INSULATION LISTED ON THE COMPLIANCE FORM AS
 R-13. IT APPEARS THAT THIS IS MEANT TO BE THE R-VALUE
 OF THE WOOD FRAME WALL BETWEEN THE GARAGE AND THE
 LIVING SPACE. PLEASE CORRECT.
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-10-01 Cont ID  
Sent By tklarge Date 2015-10-01 Time 08:40 Rev Time 0.00
Received By tklarge Date 2015-10-01 Time 08:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-06-17 Cont ID  
Sent By tklarge Date 2015-06-12 Time 11:36 Rev Time 0.00
Received By tklarge Date 2015-06-12 Time 13:51 Sent To  
Notes
2015-06-12 13:53:18SUBMIT A SANITARY PLUMBING RISER DIAGRAM FOR REVIEW PER
 WPB AMEND. TO 2010 FBC SEC. 107.3.5.3.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2015-10-21 Cont ID  
Sent By rmcdouga Date 2015-07-13 Time 16:44 Rev Time 0.00
Received By rmcdouga Date 2015-07-13 Time 16:44 Sent To  
Notes
2015-07-13 16:46:43ENTEGRA ESTATE 'S' TILE, NOA NO.14-1120.08
 3M, AH-160 FOAM ROOF TILE ADHESIVE, NOA NO.13-0502.02

Review Stop Z ZONING
Rev No 2 Status P Date 2015-09-30 Cont ID  
Sent By rmcdouga Date 2015-10-06 Time 15:32 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-05-19 Cont ID  
Sent By sgraham Date 2015-05-19 Time 16:05 Rev Time 0.00
Received By sgraham Date 2015-05-19 Time 16:05 Sent To  
Notes
2015-05-19 16:07:335/19/15 ZONING FAILED
  
 1. SIDE SETBACK IS A TOTAL OF 15' BETWEEN THE TWO SIDE
 YARDS, YOU WOULD NEED 5' AND 10' NOT 5' AND 9'.