| Plan Review Stops For Permit 15050392 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-31 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-31 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2015-08-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-12 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-12 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2015-08-12 16:30:40 | FITH BUILDING REVIEW COMMENTS: | | | | | | | | | NOTE: THE FOLLOWING COMMENTS MAY BE APPROVED WITH | | | PROVISO. WAITING FOR CONTRACTOR'S CONFIRMATION ON | | | PROVISO. FEES MAY APPLY. | | | | | | 1- PROVIDE DRAINAGE PLAN. SEC R401.3 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | ***RESPONSE TO ARCHITECT'S E-MAIL DATED 8/11/15 (SEE | | | COPY BELOW): | | | NOTE ON DRAWING A201 PARTIALLY ADDRESSES THE | | | REQUIREMENT. IT ONLY MENTION GUTTERS AND LEADERS. THE | | | PURPOSE OF THIS CODE SECTION IS TO PROVIDE A LOT | | | GRADING PLAN SHOWING HOW DIVERTING ALL THE SURFACE | | | DRAINAGE TO A STORM SEWER CONVEYANCE OR OTHER APPROVED | | | POINT OF COLLECTION. | | | | | | 2- SOIL TEST REPORT IS INCOMPLETE. PROVIDE SOIL TEST | | | REPORT WITH ALL THE INFORMATION AS REQUIRED BY SEC. | | | 1803.6 FBC-2010. | | | | | | ***RESPONSE TO ARCHITECT'S E-MAIL DATED 8/11/15 (SEE | | | COPY BELOW): | | | MARK FROM DELCREST WILL GET THE SOIL TEST REPORT WITH | | | ALL THE INFORMATION. | | | | | | 3- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING AS | | | REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS. SPECIFY | | | TYPE AND NUMBER OF NAILS OR SCREWS. | | | | | | ***RESPONSE TO ARCHITECT'S E-MAIL DATED 8/11/15 (SEE | | | COPY BELOW): | | | REVISED DRAWING A801 WAS NOT SUBMITTED TO THE CITY YET. | | | E-MAIL ATTACHMENT SHOWS TYPICAL 1-STORY WALL SECTION | | | DETAIL D1 WITH THE FOLLOWING SPECIFICATIONS: "ENTEGRA | | | FLAT ROOF TILE (NAIL W/ (2) 8D GALV RINGSHANK COIL | | | NAILS PER TILE. SEE ROOFING PERMIT". ROOF TILE FLORIDA | | | PRODUCT APPROVAL FL7804-R7 SUBMITTED DOESN'T HAVE ANY | | | INFORMATION SHOWING THE PROPOSED FASTENING. WITHOUT THE | | | ATTACHMENT RESISTANCE INFORMATION I CAN NOT VERIFY IF | | | THE PROPOSED NAILS WILL MEET THE DESIGN PRESSURES OF | | | SEC. R301 OF 2010 FBC-RESIDENTIAL. ARCHITECT TO PROVIDE | | | CALCULATIONS SHOWING THAT THE PROPOSED NAIL-ON SYSTEM | | | WILL MEET THE DESIGN CRITERIA OF SEC. R301. (NOTE: | | | TYPICALLY MIAMI-DADE NOA'S LIST ALL THIS INFORMATION. | | | FLORIDA PRODUCT APPROVALS DON'T. THAT'S WHY THE | | | ARCHITECT NEEDS TO PROVIDE THE INFORMATION). | | | | | | 4-PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: A) MAHOGANY | | | ENTRY DOOR SIZE AND ASSEMBLY AS SHOWN ON DOOR SCHEDULE. | | | | | | ***RESPONSE TO ARCHITECT'S E-MAIL DATED 8/11/15 (SEE | | | COPY BELOW): | | | REVISED DRAWING A202 WAS NOT SUBMITTED TO THE CITY YET. | | | E-MAIL ATTACHMENT SHOWS REVISED DOOR SCHEDULE WITH | | | ENTRY DOOR #102 SIZE AS FOLLOWS 3'-4" WD X 8'-0" HGT. | | | PGT SERIES "FD-750" OUTSWING ALUMINUM FRENCH DOOR NOA | | | 14-1117.05 SUBMITTED DOESN'T COVER DOORS WITH THE WIDTH | | | SPECIFIED ON THE DOOR SCHEDULE. PROVIDE NEW PRODUCT | | | APPROVAL THAT COVERS THIS SIZE OR REVISE DOOR SCHEDULE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | | | | | | | | | | JULIO, | | | I WANT TO APOLOGIZE AS I AM NOT SURE WHAT IS HAPPENING | | | BUT IT SEEMS YOU AREN?T GETTING THE CORRECTION INFO I | | | HAVE PROVIDED ON THIS JOB. | | | ATTACHED IS MY 2ND RESPONSE LETTER TO YOU FOR THE | | | COMMENTS FROM 7/22/15. | | | ALSO ANY SHEETS THAT WERE REVISED AND CLOUDED REGARDING | | | YOUR COMMENTS BELOW | | | MY RESPONSES TO YOUR COMMENTS ARE IN GREEN BELOW | | | 1- PROVIDE DRAINAGE PLAN. SEC R401.3 OF 2010 | | | FBC-RESIDENTIAL. | | | FOR THE DRAINAGE PLAN I ADDED THE ROOF GUTTER/DRAINAGE | | | NOTE TO SHEET A201 (SEE ATTACHED SHEET A201) | | | THIS IS WHAT I HAVE DONE ON OTHER IBIS JOBS FOR SHELLEY | | | FRIEFELD (SOUTHERN HOMES) | | | | | | 2- SOIL TEST REPORT IS INCOMPLETE. PROVIDE SOIL TEST | | | REPORT WITH ALL THE | | | INFORMATION AS REQUIRED BY SEC. 1803.6 FBC-2010. | | | MARK FROM DELCREST IS TRYING TO GET THE SOIL TEST INFO | | | CORRECTED. | | | | | | 3- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING AS | | | REQUIRED BY SEC. | | | 107.2.1.2 CITY AMENDMENTS. SPECIFY TYPE AND NUMBER OF | | | NAILS OR SCREWS. | | | WE CHANGED TO NAIL DOWN ROOF ON 1ST COMMENTS AND I HAD | | | ADDED THE NOTE TO ATTACH PER ROOFING PERMIT. | | | I HAVE ADDED THE NAILING SPECIFIED BY THE ROOFING | | | PERMIT (SEE ATTACHED SHEET A901) | | | | | | 4-PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: A) MAHOGANY | | | ENTRY DOOR SIZE AND | | | ASSEMBLY AS SHOWN ON DOOR SCHEDULE. | | | MAHOGANY DOOR WAS CHANGED TO PGT FD-750 OUTSWING DOOR & | | | SIDELIGHTS ON 1ST COMMENTS (SEE ATTACHED SHEET A202) | | | I REVIEWED & APPROVED THE NOA FOR THIS WITH ALL THE | | | OTHER SUBMITTED NOA?S. | | | | | | B) ROOF TILE ADHESIVE AS SPECIFIED ON DETAIL D1 ON | | | SHEET A801. | | | | | | ROOF CHANGED TO NAIL DOWN TILE ON 1ST COMMENTS | | | | | | C) PEEL & STICK CONCRETE ROOF TILE UNDERLAYMENT AS | | | SPECIFIED ON DETAIL D1 OF SHEET A801. | | | | | | PEEL & STICK WAS ELIMINATED ON THE 1ST COMMENTS | | | | | | | | | GARY STOFFT | | | | | | - LOT 15 BP BLDG COMMENTS 02.PDF - 1501021 LOT 15 BP | | | A201 FL REV02.PDF - 1501021 LOT 15 BP A202 FL REV01.PDF |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2015-08-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-10 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-10 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2015-08-10 12:46:47 | | | | NOTE: THE FOLLOWING COMMENTS MAY BE APPROVED WITH | | | PROVISO. WAITING FOR CONTRACTOR'S CONFIRMATION ON | | | PROVISO. FEES MAY APPLY. | | | | | | FOURTH BUILDING REVIEW COMMENTS: | | | | | | 1- PROVIDE DRAINAGE PLAN. SEC R401.3 OF 2010 | | | FBC-RESIDENTIAL. | | | 2- SOIL TEST REPORT IS INCOMPLETE. PROVIDE SOIL TEST | | | REPORT WITH ALL THE INFORMATION AS REQUIRED BY SEC. | | | 1803.6 FBC-2010. | | | 3- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING AS | | | REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS. SPECIFY | | | TYPE AND NUMBER OF NAILS OR SCREWS. | | | 4-PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: A) MAHOGANY | | | ENTRY DOOR SIZE AND ASSEMBLY AS SHOWN ON DOOR SCHEDULE. | | | B) ROOF TILE ADHESIVE AS SPECIFIED ON DETAIL D1 ON | | | SHEET A801. C) PEEL & STICK CONCRETE ROOF TILE | | | UNDERLAYMENT AS SPECIFIED ON DETAIL D1 OF SHEET A801. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-07-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-30 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-30 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2015-07-30 10:51:58 | | | | | | | *****NOTES: | | | A) THE COMMENTS BELOW ARE BASED ONLY ON THE | | | RE-SUBMITTAL PACKAGE I HAVE IN FRONT OF ME TO DO THE | | | REVIEW. WHATEVER I AM ASKING FOR IS BECAUSE IS NOT | | | HERE. | | | | | | B) I ALSO NOTICED THAT THERE IS ONLY ONE SET OF PRODUCT | | | APPROVALS IN THIS PACKAGE: THE OTHER SET OF PRODUCT | | | APPROVALS WAS SIGNED OUT ON 7/24/15. THE FOLLOWING ARE | | | THE NOA'S THAT WE HAVE IN THIS PACKAGE: GARAGE DOOR NOA | | | 12-0517.16, FRENCH DOORS NOA 14-1117.05, SLIDING GLASS | | | DOORS NOA 14-0128.11, MULLIONS NOA 14-1105.01, FIXED | | | WINDOWS NOA 13-0502.03 AND HORIZONTAL SLIDING WINDOWS | | | NOA 11-1114.04. THEREFORE, WE NEED THE SECOND SET | | | RE-SUBMITTED. THE PRODUCT APPROVALS THAT WERE SIGNED | | | OUT AND THE PRODUCT APPROVALS LISTED BELOW NEED TO BE | | | REVIEWED AND APPROVED BY THE DESIGNER OF RECORD. | | | | | | | | | | | | NEW SINGLE FAMILY RESIDENCE (R3) THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: 2010 FBC. | | | | | | 1- PROVIDE DRAINAGE PLAN. SEC R401.3 OF 2010 | | | FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED). | | | | | | 2- SOIL TEST REPORT IS INCOMPLETE. PROVIDE SOIL TEST | | | REPORT WITH ALL THE INFORMATION AS REQUIRED BY SEC. | | | 1803.6 FBC-2010. (REPEAT COMMENT. NOT ADDRESSED). | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC RULE 9N-3 FOR: | | | A) MAHOGANY ENTRY DOOR SIZE AND ASSEMBLY AS SHOWN ON | | | PLANS. (REPEAT COMMENT. NOT ADDRESSED). | | | B) ROOF TILE. (REPEAT COMMENT. NOT ADDRESSED) | | | C) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL | | | FOR LISTED ADHESIVE. (REPEAT COMMENT. NOT ADDRESSED) | | | D) PEEL & STICK CONCRETE ROOF TILE UNDERLAYMENT AS | | | SPECIFIED ON DETAIL D1 OF SHEET A801. (REPEAT COMMENT. | | | NOT ADDRESSED) | | | E) PRECAST LINTELS AS SPECIFIED ON PLANS. (REPEAT | | | COMMENT. NOT ADDRESSED) | | | | | | 4- DESIGNER OF RECORD TO APPROVE ALL PRODUCT APPROVALS | | | IN WRITING (NOT SIGNING AND SEALING) AS REQUIRED BY | | | SEC. 107.3.4.1 CITY AMENDMENTS. NOTE: REVIEW AND | | | APPROVE ALSO ALL PRODUCT APPROVALS THAT WERE ALREADY | | | SUBMITTED. (REPEAT COMMENT. NOT ADDRESSED) | | | | | | 5- CLARIFY WHY THERE IS ANOTHER ENGINEER (NOT THE | | | ENGINEER OF RECORD) SUBMITTING A "WINDOW & DOOR | | | INSTALLATION?. ALSO, THE DESIGN PRESSURES ARE DIFFERENT | | | THAN THOSE SPECIFIED BY THE ENGINEER OF RECORD. WHICH | | | ONE IS THE ONE WITH THE CORRECT DESIGN PRESSURES? AND, | | | THE SLIDING GLASS DOORS MULLIONS ARE NOT CLEAR | | | (HORIZONTAL OR VERTICAL?). SEC. 107.2.1 CITY | | | AMENDMENTS. (REPEAT COMMENT. NOT ADDRESSED) | | | | | | 6- CLEARLY IDENTIFY MULLION SIZE FOR OPENINGS #108, | | | #109 AND #110 TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301 OF 2010 FBC-RESIDENTIAL. CLEARLY | | | IDENTIFY THE VERTICAL AND HORIZONTAL MULLIONS. (REPEAT | | | COMMENT. NOT ADDRESSED) | | | | | | 7- TRUSS PACKAGE: (REPEAT COMMENT. NOT ADDRESSED) | | | A) TRUSS PACKAGE DOESN'T COMPLY WITH SEC. 61G15-31.003. | | | THE COVER PAGE IS MISSING THE ENGINEER OF RECORD | | | INFORMATION AND EACH INDIVIDUAL TRUSS DRAWING NEEDS THE | | | TRUSS ENGINEER'S INFORMATION. | | | | | | B) ENGINEER OF RECORD TO REVIEW AND APPROVE TRUSS | | | PACKAGE BEFORE SUBMITTAL. | | | | | | NOTE: TRUSS PACKAGE DOESN'T NEED TO BE RE-SUBMITTED TO | | | THIS OFFICE NOW. ON RESIDENTIAL PROJECTS, THE | | | CONTRACTOR MAY DELIVER THE REVISED TRUSS PACKAGE TO THE | | | INSPECTOR AT TIME OF FRAMING INSPECTION. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE REVIEW PROCESS. (REPEAT COMMENT. | | | RESPONSE LETTER NOT SUBMITTED. REVIEW TOOK LONGER | | | LOOKING FOR THE INFORMATION). | | | ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING. | | | SUBMITT OLD COPY FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-07-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-22 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-22 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2015-07-22 11:01:34 | | | | ****NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. COMMENTS | | | BELOW MAY BE ADDRESSED AFTER PERMIT IS PRINTED. | | | REVISION FEES MAY APPLY. CONTRACTOR TO ADVICE IF THE | | | PROVISO OPTION IS ACCEPTABLE. OTHERWISE, RESUBMIT | | | REQUIRED INFORMATION BEFORE ISSUING PERMIT. | | | | | | | | | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | | | | 1- PROVIDE DRAINAGE PLAN. SEC R401.3 OF 2010 | | | FBC-RESIDENTIAL. | | | 2- SOIL TEST REPORT IS INCOMPLETE. PROVIDE SOIL TEST | | | REPORT WITH ALL THE INFORMATION AS REQUIRED BY SEC. | | | 1803.6 FBC-2010. | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC RULE 9N-3 FOR: | | | A) MAHOGANY ENTRY DOOR SIZE AND ASSEMBLY AS SHOWN ON | | | PLANS. (REPEAT COMMENT. NOT ADDRESSED). | | | B) ROOF TILE. (REPEAT COMMENT. NOT ADDRESSED) | | | C) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL | | | FOR LISTED ADHESIVE. (REPEAT COMMENT. NOT ADDRESSED) | | | D) PEEL & STICK CONCRETE ROOF TILE UNDERLAYMENT AS | | | SPECIFIED ON DETAIL D1 OF SHEET A801. (REPEAT COMMENT. | | | NOT ADDRESSED) | | | E) PRECAST LINTELS AS SPECIFIED ON PLANS. (REPEAT | | | COMMENT. NOT ADDRESSED) | | | | | | 4- DESIGNER OF RECORD TO APPROVE ALL PRODUCT APPROVALS | | | IN WRITING (NOT SIGNING AND SEALING) AS REQUIRED BY | | | SEC. 107.3.4.1 CITY AMENDMENTS. NOTE: REVIEW AND | | | APPROVE ALSO ALL PRODUCT APPROVALS THAT WERE ALREADY | | | SUBMITTED. (REPEAT COMMENT. NOT ADDRESSED) | | | | | | 5- CLARIFY WHY THERE IS ANOTHER ENGINEER (NOT THE | | | ENGINEER OF RECORD) SUBMITTING A "WINDOW & DOOR | | | INSTALLATION?. ALSO, THE DESIGN PRESSURES ARE DIFFERENT | | | THAN THOSE SPECIFIED BY THE ENGINEER OF RECORD. WHICH | | | ONE IS THE ONE WITH THE CORRECT DESIGN PRESSURES? AND, | | | THE SLIDING GLASS DOORS MULLIONS ARE NOT CLEAR | | | (HORIZONTAL OR VERTICAL?). SEC. 107.2.1 CITY | | | AMENDMENTS. (REPEAT COMMENT. NOT ADDRESSED) | | | | | | 6- CLEARLY IDENTIFY MULLION SIZE FOR OPENINGS #108, | | | #109 AND #110 TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301 OF 2010 FBC-RESIDENTIAL. CLEARLY | | | IDENTIFY THE VERTICAL AND HORIZONTAL MULLIONS. (REPEAT | | | COMMENT. NOT ADDRESSED) | | | | | | 7- TRUSS PACKAGE: (REPEAT COMMENT. NOT ADDRESSED) | | | A) TRUSS PACKAGE DOESN'T COMPLY WITH SEC. 61G15-31.003. | | | THE COVER PAGE IS MISSING THE ENGINEER OF RECORD | | | INFORMATION AND EACH INDIVIDUAL TRUSS DRAWING NEEDS THE | | | TRUSS ENGINEER'S INFORMATION. | | | | | | B) ENGINEER OF RECORD TO REVIEW AND APPROVE TRUSS | | | PACKAGE BEFORE SUBMITTAL. | | | | | | NOTE: TRUSS PACKAGE DOESN'T NEED TO BE RE-SUBMITTED TO | | | THIS OFFICE NOW. ON RESIDENTIAL PROJECTS, THE | | | CONTRACTOR MAY DELIVER THE REVISED TRUSS PACKAGE TO THE | | | INSPECTOR AT TIME OF FRAMING INSPECTION. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE REVIEW PROCESS. (REPEAT COMMENT. | | | RESPONSE LETTER NOT SUBMITTED. REVIEW TOOK LONGER | | | LOOKING FOR THE INFORMATION). | | | ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING. | | | SUBMITT OLD COPY FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-06-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-06-27 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-06-27 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2015-06-27 16:59:53 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF PAID RECEIPT. COUNTY IMPACT FEE | | | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | | | | | 2- NEED TO SPECIFY CARBON MONOXIDE ALARMS. SEC R315 OF | | | 2010 FBC-RESIDENTIAL. | | | | | | 3- SHEET A901: REVISE THE SLIDING GLASS DOORS AND | | | WINDOWS HEAD AND JAMB NOTES. BEVELED BUCKS ARE NOT | | | ALLOWED. SEC. R612.10.2 OF 2010 FBC-RESIDENTIAL. | | | | | | 4- SHEET S2: | | | A) DETAIL 1/S2 IS MISSING THE ROOF SHEATHING NAIL TYPE, | | | SIZE AND SPACING. SEC. R803.2.3.1 OF 2010 | | | FBC-RESIDENTIAL. NOTE: COORDINATE WITH ITEM #5 BELOW. | | | | | | B) SPECIFY THE ATTIC LIVE LOAD AS REQUIRED BY TABLE | | | R301.5 OF 2010 FBC-RESIDENTIAL. | | | | | | 5- DETAIL 12/S3: SEC R803.2.3.1 OF 2010 FBC-RESIDENTIAL | | | REQUIRES 8D RING SHANK NAILS MIN. PLYWOOD BLOCKING | | | DETAIL CALLS FOR 10D NAILS. REVISE AS REQUIRED OR | | | PROVIDE CALCULATIONS SHOWING THAT 10D NAILS ARE EQUAL | | | OR BETTER THAN 8D RING SHANK NAILS. SEC. 107.2.1.3 CITY | | | AMENDMENTS. NOTE: COORDINATE WITH ITEM # 4(A) ABOVE. | | | | | | 6- PROVIDE DRAINAGE PLAN. SEC R401.3 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | 7- SOIL TEST REPORT IS INCOMPLETE. PROVIDE SOIL TEST | | | REPORT WITH ALL THE INFORMATION AS REQUIRED BY SEC. | | | 1803.6 FBC-2010. | | | | | | 8- REVISE THE ENERGY CALCULATIONS. SEC 103.2.1.1.2 OF | | | 2010 FBC-ENERGY CONSERVATION: | | | A) PROVIDE CORRECT BUILDER'S NAME, CORRECT PERMIT | | | OFFICE AND CORRECT JURISDICTION NUMBER ON TOP OF FORM. | | | | | | B) IDENTIFY WHERE ARE THE INSULATED DOORS SHOWN ON PAGE | | | 4 OF 6. IT DOESN'T MATCH PLANS AND PRODUCT APPROVALS. | | | | | | C) REVISE THE BUILDING ORIENTATION TO MATCH PLANS. AND, | | | REVISE THE WALLS AND WINDOWS ORIENTATION ACCORDINGLY. | | | | | | D) REVISE THE OVERHANG DEPTH AND SEPARATION OF EACH | | | WINDOW/DOOR TO MATCH PLANS. | | | | | | ***NOTE: WINDOWS AND DOORS LABELS WILL BE REQUIRED | | | SHOWING THE U-FACTOR AND SHGC FACTOR SPECIFIED ON ITEM | | | #7. | | | | | | 9- PROVIDE STRUCTURAL FRAMING DETAIL FOR OVAL WINDOWS | | | AS SHOWN ON PLANS. SEC. R301.1 OF 2010 FBC-RESIDENTIAL. | | | | | | 10- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) MAHOGANY ENTRY DOOR SIZE ASSEMBLY AS SHOWN ON PLANS. | | | | | | B) ROOF TILE. | | | | | | C) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL | | | FOR LISTED ADHESIVE. | | | | | | D) PEEL & STICK CONCRETE ROOF TILE UNDERLAYMENT AS | | | SPECIFIED ON DETAIL D1 OF SHEET A801. | | | | | | E) PRECAST LINTELS AS SPECIFIED ON PLANS. | | | | | | 11- ENGINEER OF RECORD TO REVIEW AND APPROVE ALL | | | PRODUCT APPROVALS IN WRITING (NOT SIGNING AND SEALING) | | | AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 12- CLARIFY WHY THERE IS ANOTHER ENGINEER (NOT THE | | | ENGINEER OF RECORD) SUBMITTING A "WINDOW & DOOR | | | INSTALLATION?. ALSO, THE DESIGN PRESSURES ARE DIFFERENT | | | THAN THOSE SPECIFIED BY THE ENGINEER OF RECORD. WHICH | | | ONE IS THE ONE WITH THE CORRECT DESIGN PRESSURES? AND, | | | THE SLIDING GLASS DOORS MULLIONS ARE NOT CLEAR | | | (HORIZONTAL OR VERTICAL?). SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | 13- CLEARLY IDENTIFY MULLION SIZE FOR OPENINGS #108, | | | #109 AND #110 TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301 OF 2010 FBC-RESIDENTIAL. CLEARLY | | | IDENTIFY THE VERTICAL AND HORIZONTAL MULLIONS. | | | | | | 14- SLIDING GLASS DOORS NOA 14-0128.11. PAGE 6 OF 22 | | | WAS HIGHLIGHTED WITH TABLE 1A WITH LOWER SILL HEIGHT. | | | DOORS WITH LOW SILL HEIGHT DON'T MEET THE DESIGN | | | PRESSURES FOR OPENING #110. REVISE AS REQUIRED. | | | | | | 15- TRUSS PACKAGE: | | | A) TRUSS PACKAGE DOESN'T COMPLY WITH SEC. 61G15-31.003. | | | THE COVER PAGE IS MISSING THE ENGINEER OF RECORD | | | INFORMATION AND EACH INDIVIDUAL TRUSS DRAWING NEEDS THE | | | TRUSS ENGINEER'S INFORMATION. | | | | | | B) ENGINEER OF RECORD TO REVIEW AND APPROVE TRUSS | | | PACKAGE BEFORE SUBMITTAL. | | | | | | NOTE: TRUSS PACKAGE DOESN'T NEED TO BE RE-SUBMITTED TO | | | THIS OFFICE NOW. ON RESIDENTIAL PROJECTS, THE | | | CONTRACTOR MAY DELIVER THE REVISED TRUSS PACKAGE TO THE | | | INSPECTOR AT TIME OF FRAMING INSPECTION. | | | | | | 16- VALUATION DECLARED IN THE PERMIT APPLICATION IS | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. VALUATION WAS UPDATED TO $568,741. THE | | | PERMIT FEE BALANCE IS $8938.19. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE REVIEW PROCESS. | | | ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING. | | | SUBMITT OLD COPY FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-07-27 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-27 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-07-27 |
Time |
12:30 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-07-02 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-02 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-07-02 |
Time |
09:05 |
Sent To |
I |
|
| Notes |
| 2015-07-02 10:36:36 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE | | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | | THE CORRECTIONS NOTED. | | | | | | THE FOLLOWING ITEMS SHALL BE CORRECTED AND THE PLANS | | | RESUBMITTED FOR A SECOND REVIEW: | | | 1. ELECTRICAL NOTES, GENERAL #6, PLEASE NOTE THAT ROMEX | | | IS A BRAND NAME AND NOT A CABLE TYPE. CORRECT THE NOTE | | | TO REFLECT THE CABLE TYPE INTENDED FOR USE. | | | 2. ELECTRICAL NOTES, GENERAL #13, ANY CONDUCTOR EXPOSED | | | TO WET LOCATIONS, REGARDLESS OF SIZE SHALL BE LISTED | | | ACCORDINGLY. | | | 3. ELECTRICAL NOTES, OUTLETS #3, TAMPER-RESISTANT | | | OUTLETS REQUIREMENTS IS AT NEC 406.11 AND NOT AT NEC | | | 210.52. CORRECT NOTE ACCORDINGLY. | | | 4. ELECTRICAL NOTES, SMOKE DETECTOR #2, SHALL BE | | | AMENDED TO INCLUDE THE TIP OF A CEILING/PADDLE FAN | | | BLADE. | | | 5. REVISE THE ELECTRICAL RISER DIAGRAM TO INCLUDE THE | | | INTER-SYSTEM BONDING TERMINAL REQUIRED BY NEC 520.94 | | | 6. IF AHU #1 IN GARAGE 1 IS TO BE INSIDE THE ATTIC OR | | | ON A PLATFORM, THE REQUIREMENTS OF NEC 110.33(B) SHALL | | | APPLY. THIS MAY ALSO APPLY TO AHU #2 IN GARAGE 2. | | | 7. FBC-R SECTION 315 STATES THAT YOU SHALL HAVE CARBON | | | MONOXIDE (CO) DETECTION WITHIN 10? OF EVERY SLEEPING | | | AREA. THEREFORE, THOSE DETECTORS OUTSIDE THE BEDROOM | | | USED TO COMPLY W/FBC-R 314 SHALL BE COMBINATION TYPE | | | DETECTORS. | | | 8. NEC 210.52(E)(1) REQUIRES THAT THERE BE A GFCI | | | PROTECTED RECEPTACLE INSTALLED AT THE FRONT & BACK OF | | | THE RESIDENCE. | | | 9. NEC 406.8 REQUIRES THAT ALL RECEPTACLES INSTALLED IN | | | WET LOCATIONS NOT ONLY HAVE AN IN-USE TYPE COVE BUT | | | ALSO BE LISTED AS WEATHER RESISTANT ?WR?. | | | 10. FBC-ENERGY CONSERVATION REQUIRES THAT AT LEAST 50% | | | OF ALL LAMPS IN PERMANENTLY INSTALLED FIXTURES BE | | | HIGH-EFFICIENCY. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-31 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-24 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2015-08-24 13:23:19 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-08-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-12 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-12 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2015-08-12 16:26:29 | RECEIVED E-MAIL FROM GARY STOFFT (ARCHITECT). SEE | | | BELOW: | | | | | | JULIO, | | | | | | I WANT TO APOLOGIZE AS I AM NOT SURE WHAT IS HAPPENING | | | BUT IT SEEMS YOU AREN?T GETTING THE CORRECTION INFO I | | | HAVE PROVIDED ON THIS JOB. | | | | | | ATTACHED IS MY 2ND RESPONSE LETTER TO YOU FOR THE | | | COMMENTS FROM 7/22/15. | | | | | | ALSO ANY SHEETS THAT WERE REVISED AND CLOUDED REGARDING | | | YOUR COMMENTS BELOW | | | | | | ? | | | | | | MY RESPONSES TO YOUR COMMENTS ARE IN GREEN BELOW | | | | | | ? | | | | | | 1-??? PROVIDE DRAINAGE PLAN. SEC R401.3 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | FOR THE DRAINAGE PLAN I ADDED THE ROOF GUTTER/DRAINAGE | | | NOTE TO SHEET A201 (SEE ATTACHED SHEET A201) | | | | | | THIS IS WHAT I HAVE DONE ON OTHER IBIS JOBS FOR SHELLEY | | | FRIEFELD (SOUTHERN HOMES) | | | 2- SOIL TEST REPORT IS INCOMPLETE. PROVIDE SOIL TEST | | | REPORT WITH ALL THE | | | INFORMATION AS REQUIRED BY SEC. 1803.6 FBC-2010. | | | | | | MARK FROM DELCREST IS TRYING TO GET THE SOIL TEST INFO | | | CORRECTED. | | | 3- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING AS | | | REQUIRED BY SEC. | | | 107.2.1.2 CITY AMENDMENTS. SPECIFY TYPE AND NUMBER OF | | | NAILS OR SCREWS. | | | | | | WE CHANGED TO NAIL DOWN ROOF ON 1ST COMMENTS AND I HAD | | | ADDED THE NOTE TO ATTACH PER ROOFING PERMIT. | | | | | | I HAVE ADDED THE NAILING SPECIFIED BY THE ROOFING | | | PERMIT (SEE ATTACHED SHEET A901) | | | 4-PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: A) MAHOGANY | | | ENTRY DOOR SIZE AND | | | ASSEMBLY AS SHOWN ON DOOR SCHEDULE. | | | | | | MAHOGANY DOOR WAS CHANGED TO PGT FD-750 OUTSWING DOOR & | | | SIDELIGHTS ON 1ST COMMENTS (SEE ATTACHED SHEET A202) | | | | | | I REVIEWED & APPROVED THE NOA FOR THIS WITH ALL THE | | | OTHER SUBMITTED NOA?S. | | | | | | B) ROOF TILE ADHESIVE AS SPECIFIED ON DETAIL D1 ON | | | SHEET A801. | | | | | | ROOF CHANGED TO NAIL DOWN TILE ON 1ST COMMENTS | | | | | | C) PEEL & STICK CONCRETE ROOF TILE UNDERLAYMENT AS | | | SPECIFIED ON DETAIL D1 OF SHEET A801. | | | | | | PEEL & STICK WAS ELIMINATED ON THE 1ST COMMENTS | | | | | | | | | ? | | | | | | ?????????????GARY STOFFT | | | | | | | | | | | | ????????????????? 42?? N? SWINTON AVENUE | | | | | | ????????????????? DELRAY??? BCH FL???? 33444 | | | ????????????????? OFFICE? 561-243-0799 EXT?108 | | | ????????????????? FAX??????????????????? 561-243-0299 | | | | | | ? | | | | | | DELRAY BEACH - NAPLES ? CARIBBEAN | | | | | | | | | CONFIDENTIALITY NOTICE: THIS EMAIL MESSAGE, INCLUDING | | | ANY AND ALL ATTACHMENTS, IS FOR THE SOLE USE OF THE | | | INTENDED RECIPIENTS AND MAY CONTAIN CONFIDENTIAL, | | | COPYRIGHTED AND PRIVILEGED INFORMATION. ANY | | | UNAUTHORIZED REVIEW, USE, DISCLOSURE AND OR | | | DISTRIBUTION IS PROHIBITED. WRITTEN PERMISSION FROM THE | | | SENDER IS REQUIRED PRIOR FORWARDING THIS MESSAGE TO | | | ANYONE NOT REFERENCED TO AS EITHER THE RECIPIENT OR A | | | COPIED ENTITY.? IF YOU ARE NOT THE INTENDED RECIPIENT, | | | PLEASE CONTACT THE SENDER BY EMAIL AND IMMEDIATELY | | | DELETE ALL COPIES OF THE ORIGINAL AND COPIED MESSAGE. | | | | | | ? | | | | | | DISCLAIMER:?DOWNLOADING FROM THE ABOVE SITE OR USING | | | THE FILES IN ANY MANNER INDICATES YOUR ACCEPTANCE OF | | | TERMS AND CONDITIONS AS SET FORTH BELOW. IF YOU DO NOT | | | AGREE TO ALL OF THE TERMS AND CONDITIONS, PLEASE | | | CONTACT OUR OFFICE PRIOR TO ANY DOWNLOADING OF THE | | | REFERENCED INFORMATION. PLEASE BE ADVISED THAT THE | | | ATTACHED FILES ARE IN A FORMAT THAT CAN BE ALTERED BY | | | THE USER. DUE TO THIS FACT, ANY REUSE OF THE DATA WILL | | | BE AT THE USER'S SOLE RISK WITHOUT LIABILITY OR LEGAL | | | EXPOSURE TO RANDALL STOFFT ARCHITECTS AND USER SHALL | | | INDEMNIFY AND HOLD HARMLESS RANDALL STOFFT ARCHITECTS | | | FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES INCLUDING | | | ATTORNEY'S FEES ARISING OUT OF OR RESULTING FROM USING | | | THE DIGITAL FILE. IN ADDITION, IT IS THE RESPONSIBILITY | | | OF THE USER TO COMPARE ALL DATA WITH THE SIGNED AND | | | SEALED DRAWING(S). IN THE EVENT THERE IS A CONFLICT | | | BETWEEN THE SIGNED AND SEALED DRAWING(S) AND THE | | | ELECTRONIC FILE, THE SIGNED AND SEALED DRAWING(S) SHALL | | | PREVAIL. | | | | | | ? - LOT 15 BP BLDG COMMENTS 02.PDF - 1501021 LOT 15 BP | | | A201 FL REV02.PDF - 1501021 LOT 15 BP A202 FL REV01.PDF |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-08-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-10 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-04 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2015-08-04 09:09:49 | RE-SUBMITTAL SENT TO JULIO GOMEZ FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-07-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-07-29 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-07-28 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2015-07-29 09:55:37 | CCOLE DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-07-27 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-27 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-07-06 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2015-07-27 17:15:33 | 7/27/15 - PASSED ELECTRICAL BUT FAILED OTHER TRADES. | | | CONTRACTOR NOTIFIED VIA VOICE MAIL. SENT TO LARGE | | | DENIED BIN "D". MA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-07-02 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-07-02 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-05-12 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2015-07-02 10:40:37 | CONTRACTOR NOTIFIED OF FAILED REVIEWS VIA EMAIL. SENT | | | TO LARGE DENIED BIN "D". | | 2015-05-13 10:53:19 | SENT TO R26 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2015-09-01 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-01 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-01 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-31 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-31 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2015-08-31 18:05:02 | 1- NEED COPY OF THE IMPACT FEES PAID RECEIPT. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-07-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-22 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-22 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2015-07-22 11:21:22 | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF PAID RECEIPT. COUNTY IMPACT FEE | | | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-06-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-06-29 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-06-29 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2015-06-29 08:24:34 | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF PAID RECEIPT. COUNTY IMPACT FEE | | | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-07-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-07-29 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-07-29 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-07-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-07-27 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-07-27 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2015-07-27 12:02:38 | 2ND REVIEW: FBC 2010 MECHANICAL | | | 7/27/15 | | | | | | 1) THE CORRECTED AC PLAN IS INCOMPLETE- SHOW THE DUCT | | | RUNS AND DUCT SIZES FOR THE SUPPLY REGISTERS AT THE | | | MASTER BEDROOM, MASTER BATH, MASTER WALK-IN CLOSETS, | | | BATH-2, BEDROOM-2 WALK-IN CLOSET, POWDER ROOM, STORAGE | | | ROOM, AND WALK-IN CLOSET-3. SHOW THE MASTER BEDROOM | | | TRANSFER RETURN DUCT AND SIZE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-06-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-06-30 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-06-30 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2015-06-30 12:59:44 | 1ST REVIEW: FBC 2010 RESIDENTIAL | | | | | | 1) PROVIDE A MEANS OF RETURN AIR FROM THE MASTER | | | BEDROOM- SECTION M1602.4 FBC-10 RESIDENTIAL. | | | 2) INDICATE THE DIMENSIONS OF THE RETURN GRILLS IN | | | BEDROOMS 2 & 3, AND THE LIBRARY- M1602.4. | | | 3) INDICATE THE DIMENSIONS OF THE RETURN AIR PLENUM | | | DUCTS, AND PLACE A NOTE THAT NO FLEX DUCTS ARE | | | PERMITTED TO BE INSTALLED IN THE GARAGE PER SECTION | | | R302.5.2. | | | 4) PROVIDE CONDENSATE DISPOSAL DETAILS- M1411.3 & | | | M1411.3.1. | | | 5) PROVIDE STRUCTURAL DETAILS FOR INSTALLATION OF THE | | | CONDENSER PADS, AND TIE-DOWN ENGINEERING FOR THE | | | CONDENSERS- M1307.2.1. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-06-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-12 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-12 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-31 |
Time |
18:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-31 |
Time |
18:06 |
Sent To |
|
|
| Notes |
| 2015-08-31 18:07:05 | ROOF TILE NOA 14-1120.04. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2015-08-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-10 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-10 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2015-07-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-07-22 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-07-22 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2015-07-22 15:48:35 | 1 PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC RULE 9N-3 FOR: | | | A) ROOF TILE. | | | | | | B) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL | | | FOR LISTED ADHESIVE. | | | | | | C) PEEL & STICK CONCRETE ROOF TILE UNDERLAYMENT AS | | | SPECIFIED ON DETAIL D1 OF SHEET A801. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-06-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-06-29 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-06-29 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2015-06-29 16:28:37 | 1 PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) ROOF TILE. | | | | | | B) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL | | | FOR LISTED ADHESIVE. | | | | | | C) PEEL & STICK CONCRETE ROOF TILE UNDERLAYMENT AS | | | SPECIFIED ON DETAIL D1 OF SHEET A801. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-06-17 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-06-17 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-06-17 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2015-06-17 10:37:42 | 6/17/15 - REQUIRED LANDSCAPE PLAN SUBMITTED 6/16/15 FOR | | | REVIEW (15060679). DK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-05-19 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-05-19 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2015-06-02 13:19:53 | 6/2/15 - APPLICANT SUBMITTED MISSING SURVEYS 6/1/15. | | | COMMENT #1 BELOW HAS BEEN BEEN MET. DK | | | | | 2015-05-19 15:57:55 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 5/19/2015 | | | | | | ITEMS TO BE ADDRESSED: | | | | | | 1. THERE WAS NO PROPERTY SURVEY INCLUDED IN THE | | | SUBMITTAL. PLEASE SUBMIT TWO COPIES OF THE PROPERTY | | | SURVEY. | | | | | | 2. A SEPARATE LANDSCAPE PERMIT IN CONFORMANCE WITH | | | ARTICLE XIV SHALL BE SUBMITTED. (NOTE: ZLDR SEC. | | | 94-442(B)(2)A. - FOR SINGLE-FAMILY DWELLING UNITS, AT | | | LEAST ONE SHADE, FLOWERING, OR FRUIT TREE SHALL BE | | | PLANTED FOR EACH 1,200 SQUARE FEET OF OPEN SPACE OR | | | PORTION THEREOF. FOR SINGLE-FAMILY DWELLING UNITS, AT | | | LEAST ONE SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE | | | FEET OF OPEN SPACE OR PORTION THEREOF. PLEASE ADJUST | | | CALCULATIONS TABLE.) | | | | | | GENERAL COMMENTS: | | | | | | 3. SEPARATE PERMITS ARE REQUIRED FOR THE POOL AND | | | DRIVEWAY. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | | |
|
|