Plan Review Details - Permit 15050330
| Plan Review Stops For Permit 15050330 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-06-24 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-06-24 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-06-24 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-05-18 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-18 |
Time |
16:23 |
Rev Time |
|
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-05-18 16:23:19 | 1ST REVIEW: FBC 2010 | | | | | | MET WITH RAINER GEBAUER, HUSBAND OF OWNER, HE INDICATED | | | THE DRAWING DOES NOT DEPICT THE ACTUAL SCOPE OF WOTK SO | | | HE WILL RESUBMIT AN ACCURATE DRAWING AT A LATER DATE. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-06-17 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-06-17 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-06-17 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2015-06-17 14:14:57 | 6/17/2015 | | | PROJECT: KITCHEN RENNOVATION | | | PERMIT#: 15050330 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN | | | APPROVED PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | | DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED | | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | | FEE(S). | | | | | | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | | COMMENTS: | | | | | | 1) INSTAL SMOKE DETECTORS WHERE REQUIRED. SEE FBC-R | | | 314-315 WHEN ALTERATIONS, REPAIRS, OR ADDITIONS | | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | | INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE | | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | FBC-RESIDENTIAL 314 AND 315. | | | | | | 2) ALL NEW GENERAL PURPOSE OUTLETS MUST BE TAMPER | | | RESISTANT AND AFCI PROTECTED. NEC 210.12, 406.11 | | | | | | 3) NEC 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER | | | PROTECTION FOR PERSONNEL. | | | (A) DWELLING UNITS. ALL 125-VOLT, SINGLE-PHASE, 15- AND | | | 20-AMPERE RECEPTACLES INSTALLED IN THE LOCATIONS | | | SPECIFIED IN (1) THROUGH (8) SHALL HAVE GROUND-FAULT | | | CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. (1) | | | BATHROOMS. | | | | | | 4) NEC 210.52 (D) BATHROOMS. IN DWELLING UNITS, AT | | | LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED IN | | | BATHROOMS WITHIN (3 FT) OF THE OUTSIDE EDGE OF EACH | | | BASIN. | | | | | | 5) NEC 210.52(C)(1) WALL COUNTERTOP SPACES. A | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH WALL | | | COUNTERTOP SPACE THAT IS 300 MM (12 IN.) OR WIDER | | | | | | 6) FBC-E 708.3 RESIDENTIAL OCCUPANCIES. | | | IN GROUP R-2, R-3, AND R-4 OCCUPANCIES AND BUILDINGS | | | REGULATED BY THE FLORIDA BUILDING CODE, RESIDENTIAL, | | | THE REQUIREMENTS OF SECTIONS 708.3.1 THROUGH 708.3.7 | | | SHALL BE APPLICABLE ONLY TO WORK AREAS LOCATED WITHIN A | | | DWELLING UNIT. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-05-14 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-05-14 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-05-14 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-06-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-06-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-06-22 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2015-06-22 14:54:21 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE NATURE OF THE REMODEL MAY REQUIRE AN EVALUATION OF | | | THE FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE | | | AND COMPLIANCE. | | | | | | EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER, SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-05-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-05-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-05-13 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2015-05-13 13:11:01 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE NATURE OF THE REMODEL MAY REQUIRE AN EVALUATION OF | | | THE FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE | | | AND COMPLIANCE. | | | | | | EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER, SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-06-24 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-06-24 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-06-15 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-05-18 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-18 |
Time |
16:23 |
Rev Time |
|
| Received By |
skennedy |
Date |
2015-05-11 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-05-12 09:22:36 | SENT TO B-26. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2015-05-18 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-18 |
Time |
16:20 |
Rev Time |
|
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-05-18 16:22:28 | 1ST REVIEW: FBC 2010 | | | | | | MET WITH RAINER GEBAUER, HUSBAND OF OWNER, HE INDICATED | | | THE DRAWING DOES NOT DEPICT THE ACTUAL SCOPE OF WOTK SO | | | HE WILL RESUBMIT AN ACCURATE DRAWING AT A LATER DATE. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-05-18 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-18 |
Time |
16:22 |
Rev Time |
|
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-05-18 16:22:54 | 1ST REVIEW: FBC 2010 | | | | | | MET WITH RAINER GEBAUER, HUSBAND OF OWNER, HE INDICATED | | | THE DRAWING DOES NOT DEPICT THE ACTUAL SCOPE OF WOTK SO | | | HE WILL RESUBMIT AN ACCURATE DRAWING AT A LATER DATE. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
|