Plan Review Details - Permit 15050092
Plan Review Stops For Permit 15050092
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-06-04 Cont ID  
Sent By albarran Date 2015-06-04 Time 14:13 Rev Time 0.00
Received By albarran Date 2015-06-04 Time 13:53 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-05-15 Cont ID  
Sent By dhayes Date 2015-05-15 Time 08:48 Rev Time 0.00
Received By dhayes Date 2015-05-15 Time 08:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-05-20 Cont ID  
Sent By pleduc Date 2015-05-20 Time   Rev Time 0.00
Received By pleduc Date 2015-05-20 Time 16:35 Sent To E
Notes
2015-05-20 16:42:42THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 PER NFPA 101 SECTION 7.2.1.6.2, ACCESS-CONTROLLED
 EGRESS DOORS ARE PERMITTED PROVIDED THAT ALL SEVEN OF
 THE FOLLOWING CRITERIA ARE MET:
 1. A SENSOR SHALL BE PROVIDED ON THE EGRESS SIDE,
 ARRANGED TO DETECT AN OCCUPANT APPROACHING DOORS THAT
 ARE ARRANGED TO UNLOCK IN THE DIRECTION OF EGRESS UPON
 DETECTION OF AN APPROACHING OCCUPANT OR LOSS OF POWER
 TO THE SENSOR.
 2. LOSS OF POWER TO THE PART OF THE ACCESS CONTROL
 SYSTEM THAT LOCKS THE DOORS SHALL AUTOMATICALLY UNLOCK
 THE DOORS IN THE DIRECTION OF EGRESS.
 3. THE DOORS SHALL BE ARRANGED TO UNLOCK IN THE
 DIRECTION OF EGRESS FROM A MANUAL RELEASE DEVICE
 LOCATED VERTICALLY 40 TO 48 INCHES ABOVE THE FLOOR AND
 WITHIN 60 INCHES HORIZONTALLY OF THE SECURED DOORS.
 4. THE MANUAL RELEASE DEVICE SHALL BE READILY
 ACCESSIBLE AND CLEARLY IDENTIFIED BY A SIGN THAT READS
 PUSH TO EXIT.
 5. WHEN OPERATED, THE MANUAL RELEASE DEVICE SHALL
 RESULT IN DIRECT INTERRUPTION OF POWER TO THE LOCK,
 INDEPENDENT OF THE ACCESS CONTROL SYSTEM ELECTRONICS,
 AND THE DOORS SHALL REMAIN UNLOCKED FOR NOT LESS THAN
 30 SECONDS.
 6. ACTIVATION OF THE BUILDING FIRE ALARM SYSTEM SHALL
 AUTOMATICALLY UNLOCK THE DOORS IN THE DIRECTION OF
 EGRESS, AND THE DOORS SHALL REMAIN UNLOCKED UNTIL THE
 FIRE ALARM SYSTEM HAS BEEN MANUALLY RESET.
 7. ACTIVATION OF THE BUILDING AUTOMATIC SPRINKLER
 SYSTEM OR AUTOMATIC DETECTION SYSTEM SHALL
 AUTOMATICALLY UNLOCK THE DOORS IN THE DIRECTION OF
 EGRESS, AND THE DOORS SHALL REMAIN UNLOCKED UNTIL THE
 FIRE ALARM SYSTEM HAS BEEN MANUALLY RESET.
  
2015-05-19 14:40:26NEW DRAWINGS SUBMITTED. JG.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-05-05 Cont ID  
Sent By pleduc Date 2015-05-05 Time   Rev Time 0.00
Received By pleduc Date 2015-05-05 Time 14:27 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-06-04 Cont ID  
Sent By albarran Date 2015-06-04 Time 14:17 Rev Time 0.00
Received By albarran Date 2015-05-19 Time 14:38 Sent To  
Notes
2015-06-04 14:17:45SMALL READY "S"
2015-05-19 14:39:25NEW DRAWINGS SUBMITTED. SENT TO FIRE SHELF FOR REVIEW.
 JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status F Date 2015-05-15 Cont ID  
Sent By dhayes Date 2015-05-15 Time 08:48 Rev Time  
Received By dhayes Date   Time   Sent To  
Notes
2015-05-05 11:04:48ROUTED TO FIRE