Plan Review Details - Permit 15050053
| Plan Review Stops For Permit 15050053 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-05-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-05-05 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-05-05 |
Time |
12:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-05-13 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-05-13 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-05-13 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2015-05-13 15:50:23 | APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN APPROVED | | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | | DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED | | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | | FEE(S). | | | | | | 1) AT LEAT ONE GFI RECEPTACLE OUTLET SHALL BE INSTALL | | | ON A PORCH OR BALCONY ACCESSIBLE FROM INSIDE. NEC | | | 210.52(E))(3) AND NEC 210.8 | | | | | | 2) TAMPER-RESISTANT RECEPTACLES IN DWELLING UNITS. IN | | | ALL AREAS SPECIFIED IN 210.52, ALL 125-VOLT, 15- AND | | | 20-AMPERE RECEPTACLES SHALL BE LISTED TAMPERRESISTANT | | | RECEPTACLES. NEC 406.11 | | | | | | 3) RECEPTACLES INSTALLED IN A WET LOCATION SHALL HAVE | | | AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE | | | ATTACHMENT PLUG CAP IS INSERTED. ALL 15- AND 20-AMPERE, | | | 125- AND 250-VOLT NONLOCKING RECEPTACLES SHALL BE | | | LISTED WEATHER-RESISTANT TYPE. NEC 406.8 (B) (1) | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-05-06 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2015-05-06 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2015-05-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-05-05 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-05-05 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2015-05-05 13:17:18 | PLANS STAMPED FROM P B C IMPACT FEE OFFICE NO FEES DUE. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2015-05-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-05-05 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-05-05 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2015-05-05 13:16:23 | NOTE: ASTRO AIR PERMITED 5 TON 2 STAGE UNIT UNDER | | | 11030564 AND ATTESTED TO THE 100 SQ FT ADDITION THE | | | UNIT WILL BE ABLE TO STILL HAVE AMPLE COOLING CAPACITY. |
|
|
|