Plan Review Details - Permit 15050017
| Plan Review Stops For Permit 15050017 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-06-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-06-03 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-06-03 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2015-06-03 10:52:19 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FBC 109, VALUE TO INCLUDE LABOR, MATERIALS, | | | OVERHEAD, PROFIT, ENGINEERING. VALUE APPEARS TO BE TOO | | | LOW FOR ALL WORK DESCRIBED IN PLANS, AND PLANS INDICATE | | | THAT SOME ITEMS ARE PROVIDED BY OTHERS. | | | | | | 2. FBC 1609, SHEET C4 STATES THAT THIS IS RISK CATEGORY | | | II, 160 MPH. THIS SHOULD BE A MINIMUM OF 167MPH FOR | | | RISK CATEGORY II. | | | | | | 3. SHEET S1 AND OTHER SHEETS PREPARED BY ARNOLD | | | ANTILES, PE ARE POOR PHOTOCOPIES. FS471, | | | FAC61G15-23.002, ALL DOCUMENTS PREPARED BY AN ENGINEER | | | AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, | | | SEALED, DATED ORIGINALS. | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-05-18 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-05-18 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-05-18 |
Time |
17:52 |
Sent To |
B |
|
| Notes |
| 2015-05-18 18:05:54 | SENT TO SH FOR BLDG. REVIEW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-06-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-06-03 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-05-20 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2015-05-28 12:10:22 | 5/28 TO MISC 2 | | | | | | | | 2015-05-20 17:36:29 | 5/20 TO ZONING | | | | | 2015-05-01 12:47:32 | ROUTED TO ELECTRICAL OVER 5K |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-05-28 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-05-28 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-05-28 |
Time |
11:07 |
Sent To |
B |
|
| Notes |
| 2015-05-28 11:07:30 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 05.28.2015 | | | PERMIT NO.: 15050017 | | | ADDRESS: 3119 CUMBERLAND DRIVE | | | CONTRACTOR/CONTACT: TBD | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: ATTACH ANTENNAS AND PLATFORM WITH | | | ASSOCIATED EQUIPMENT ON EXISTING FPL POLE. INSTALL 50KW | | | DIESEL GENERATOR. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | WIRELESS COMMUNICATIONS ANTENNAS AND EQUIPMENT, A | | | WIRELESS COMMUNICATION FACILITY DEVELOPMENT APPLICATION | | | SHALL BE SUBMITTED TO THE DEVELOPMENT SERVICES | | | DEPARTMENT ? PLANNING DIVISION. SUCH APPLICATION WILL | | | BE REVIEWED BY THE CITY AND CITYSCAPE CONSULTANTS AND | | | SHALL BE APPROVED BEFORE ANY PERMIT MAY BE ISSUED. | | | PLEASE CONTACT ERIC SCHNEIDER, PRINCIPAL PLANNER, AT | | | 561.822.1446 OR VIA EMAIL AT [email protected] TO | | | OBTAIN A COPY OF THE APPLICATION AND/OR ANSWER ANY | | | QUESTION.. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
|