| Plan Review Stops For Permit 15050015 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-05-15 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-05-15 |
Time |
06:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-05-15 |
Time |
05:55 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-06-22 |
|
|
Cont ID |
|
| Sent By |
R Lecky |
Date |
2015-06-22 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-06-22 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2015-06-22 11:43:22 | APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN APPROVED | | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | | DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED | | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | | FEE(S). | | | | | | 1) PROVIDE A VOLTAGE DROP CALCULATION TO THE INSPECTOR | | | UPON 1ST INSPECTION IN THE FIELD INDICATING THE FEEDER | | | CONDUCTORS SHALL HAVE AN AMPACITY NOT LESS THAN | | | REQUIRED TO SUPPLY THE LOAD AS CALCULATED NEC 215.2 | | | (A)(1). MINIMUM RATING AND SIZE. | | | | | | 2) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | ARE REQUIRED FOR FIRE ALARM, ACCESS CONTROL SYSTEM, | | | POS,SECURITY, CCTV, AUDIO/VIDEO, NETWORK, DATA, AND, | | | COMMUNICATION AS NEEDED. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-05-28 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-05-28 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-05-28 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-05-04 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2015-05-04 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-05-04 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2015-05-04 15:25:05 | PERMIT # 15050015 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PROVISO: | | | | | | 1) THIS PROPERTY IS EQUIPPED WITH A COMMON FIRE ALARM | | | SYSTEM. AS PREVIOUSLY DISCUSSED WITH PROPERTY | | | MANAGERMENT, ALL TENANT SPACES MUST HAVE PROPER | | | NOTIFICATION IN THE EVENT OF A FIRE EMERGENCY. PROVIDE | | | VISUAL AND AUDIBLE NOTIFICATION APPLIANCE IN ALL PUBLIC | | | AND COMMON USE SPACES, AS REQUIRED BY NFPA 101: CHAPTER | | | 9, SECTION 9.6: FIRE DETECTION, ALARM. AND | | | COMMUNICATION SYSTEMS. 9.6.3.6.1: THE GENERAL | | | EVACUATION ALARM SIGNAL SHALL OPERATE THROUGHOUT THE | | | ENTIRE BUILDING. | | | | | | 2) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | COMMENTS: | | | | | | 1) THIS PERMIT IS BEING PROVISIONALLY APPROVED PENDING | | | COMPLIANCE WITH ALL ITEMS ABOVE. | | | | | | 2) UPDATE THE CODE LIST TO REFERENCE THE 5TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2012 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | | | | SUE ELLEN CALDERON | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 644-7326 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-06-22 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-06-22 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-06-10 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-06-11 10:16:15 | SENT TO B 30. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-05-31 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-05-31 |
Time |
06:35 |
Rev Time |
|
| Received By |
tklarge |
Date |
2015-05-01 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2015-05-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-05-15 |
Time |
06:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-05-15 |
Time |
06:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-06-17 |
|
|
Cont ID |
|
| Sent By |
C COLE |
Date |
2015-06-17 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-06-17 |
Time |
14:20 |
Sent To |
E |
|
| Notes |
| 2015-06-17 14:30:31 | PROVISIO: | | | SITE SPECIFIC WIND LOAD ENGINEERING FOR TIE-DOWN OF THE | | | RTU AND RTU CURB SHALL BE ON SITE AT TIME OF | | | INSPECTION. | | | STRUCTURAL REVISION WILL BE REQUIRED FOR ANY | | | MODIFICATIONS TO THE EXISTING ROOF STRUCTURE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-05-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-05-28 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-05-28 |
Time |
09:12 |
Sent To |
E |
|
| Notes |
| 2015-05-28 09:13:57 | 1ST REVIEW: FBC 2010 MECHANICAL | | | | | | 1) PROVIDE A VENTILATION CALCULATION FOR THE PROPOSED | | | OCCUPANCY PER TABLE 403.3 FMC-10. | | | INDICATE HOW MUCH AIR WILL BE PROVIDED BY THE NEW | | | RTU-1. | | | 2) PROVIDE AC LOAD CALCULATIONS FOR RTU-1 IN ACCORDANCE | | | WITH PROCEDURES DESCRIBED IN ASHRAE/ACCA STANDARD 183 | | | OR ACCA MANUAL N- SECTION 503.2.1 FBC-10 ENERGY. | | | 3) SHEET M-1: AUTOMATIC SHUTOFF DAMPERS AND CONTROLS | | | FOR THE O/A SUPPLIES ARE REQUIRED FOR THE TWO AC | | | SYSTEMS IN COMPLIANCE WITH SECTION 503.2.4.4 FBC-10 | | | ENERGY. PROVIDE DETAILS AND OPERATION SEQUENCE ON THE | | | PLAN. | | | 4) M-1: RETURN AIR IS BEING TRANSFERRED FROM THE BREAK | | | ROOM AND OTHER ROOMS AND OFFICES INTO THE CORRIDORS, | | | HOWEVER A CORRIDOR CANNOT BE USED TO RETURN AIR TO THE | | | UNIT- SECTION 601.2 FMC-10. PROVIDE DUCTED RETURNS FROM | | | THESE ROOMS. | | | 5) M-1: SHOW THE DUCT SMOKE DETECTOR TEST STATIONS AND | | | DESCRIBE FAN SHUT DOWN PROCEDURE OR SEQUENCE OF | | | OPERATION. | | | 6) M-2: WIND LOAD DESIGN CRITERIA- THE ENGINEER OF | | | RECORD SHALL VERIFY THE RTU AND FAN ROOF TIE-DOWN | | | DETAILS WILL WITHSTAND 170 MPH WIND LOAD AND ASSOCIATED | | | LATERAL AND UPLIFT PRESSURES. | | | 7) M-2: PROVIDE TWO COPIES OF A MIAMI-DADE NOA OR FL. | | | PRODUCT APPROVAL FOR THE EXHAUST FAN ON THE ROOF. | | | 8) M-2: PROVIDE A CONDENSATE DISPOSAL PLAN FOR THE NEW | | | RTU: SHOW TYPE AND SIZE OF PIPING, PIPING RUN, PIPING | | | SUPPORT, PIPING PROTECTION FROM EXPOSURE, AND DISCHARGE | | | LOCATION. | | | 9) M-2: INDICATE THE THICKNESS AND R-VALUE OF DUCT | | | INSULATION- TABLE 503.2.7.1 FBC-10 ENERGY. | | | | | | CHRISTOPHER COLE | | | MECHANICAL PLANS EXAMINER | | | (561) 805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-05-31 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-05-31 |
Time |
06:34 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-05-31 |
Time |
05:20 |
Sent To |
|
|
| Notes |
|
|