Plan Review Details - Permit 15041132
Plan Review Stops For Permit 15041132
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-06-25 Cont ID  
Sent By jwitmer Date 2015-06-25 Time 05:59 Rev Time 0.00
Received By jwitmer Date 2015-06-25 Time 05:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-05-01 Cont ID  
Sent By jwitmer Date 2015-05-01 Time 10:06 Rev Time  
Received By jwitmer Date 2015-05-01 Time 07:31 Sent To  
Notes
2015-05-01 09:26:20 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15041132
 ADD: 1781 PALM BEACH LAKES BLVD SUITE # W219
 CONT:TBD
 TEL: (954)789-9363
 CONTACT: JORDAN MORGAN
 E-MAIL:
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. MAY 01/2015
 ACTION: DENIED
  
 IMPORTANT NOTICE: EFFECTIVE JUNE 01, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE.
  
 1) : PALM BEACH OUTLET MALL: BEFORE PLAN SUBMITTAL TO
 THE BUILDING DEPARTMENT, THE PLANS ARE SUPPOSED TO HAVE
 THE STAMPED LANDLORD APPROVAL BY NEW ENGLAND
 DEVELOPMENT PALM BEACH OUTLETS SKY GROUP TENANT
 COORDINATOR.
  
 2) THE D.1 SHEET DOES NOT SHOW THE REMOVAL OF THE
 REQUIRED DRINKING FOUNTAIN NOR DOES THE A.1 SHEET SHOW
 THE INSTALATION OF A NEW DRINKING FOUNTAIN. UNDER THE
 2010 FLORIDA EXISTING BUILDING CODE SECTION 706.1 A
 BUILDING, FACILITY, OR ELEMENT THAT IS ALTERED SHALL
 COMPLY WITH THE PROVISIONS OF THE FLORIDA BUILDING
 CODE, ACCESSIBILITY. FBC-ACCESIBILITY CODE 202.4
 ALTERATIONS AFFECTING PRIMARY FUNCTION AREAS. UP TO 20%
 OF THE CONTRACT VALUE IS REQUIRED TO BRING THIS UNIT UP
 TO CODE OR UP TO $ 7000.00 DOLLORS. THE TENANT SPACE IS
 MISSING THE REQUIRED DRINKING FOUNTAIN PLEASE REVIEW
 THE ACCESS. CODE 211.2 MINIMUM NUMBER.
 NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-07-21 Cont ID  
Sent By dhayes Date 2015-07-21 Time 14:00 Rev Time 0.00
Received By dhayes Date 2015-07-21 Time 13:39 Sent To  
Notes
2015-07-21 14:05:00APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN APPROVED
 PROVISIONALLY. FAILURE TO CORRECT THE LISTED
 DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED
 INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION
 FEE(S).
  
 1) 505.2 LIGHTING CONTROLS (MANDATORY).
 LIGHTING SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS
 REQUIRED IN SECTIONS 505.2.1, 505.2.2, 505.2.3 AND
 505.2.4.
  
 2) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY
 MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS
 ARE REQUIRED FOR FIRE ALARM, ACCESS CONTROL SYSTEM,
 SECURITY, CCTV, AUDIO/VIDEO, NETWORK, DATA, AND,
 COMMUNICATION AND POS SYSTEMS AS NEEDED.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-06-03 Cont ID  
Sent By dhayes Date 2015-06-03 Time 14:45 Rev Time 0.00
Received By dhayes Date 2015-06-03 Time 14:45 Sent To  
Notes
2015-06-03 15:09:59NO ELECTRICAL PLAN HAS BEEN INCLUDED IN THE SUBMITTAL
 PACKAGE. NO ELECTRICAL REVIEW HAS BEEN PERFORMED AT
 THIS TIME.
  
 1) PROVIDE AN ELECTRICAL PLAN FOR REVIEW THAT INCLUDES
 THE MINIMUM PLAN REVIEW CRITERIA.
  
 WPB AMENDMENTS TO THE FBC 107.3.5.1.2 MINIMUM PLAN
 REVIEW FOR ELECTRICAL:
 1. A SERVICE RISER DIAGRAM
 2. INDICATE ALL FEEDERS AND BRANCH CIRCUITS
 3. PROVIDE A PANEL SCHEDULE WITH OVERCURRENT PROTECTION
 AND CORRESPONDING WIRE SIZES.
 4. GROUNDING AND BONDING.
 5. WIRING METHODS AND MATERIALS
 6. GFCI PROTECTION WHERE REQUIRED.
 7. AN EQUIPMENT SCHEDULE
 8. GENERAL LIGHTING
 9. EMERGENCY AND EXIT LIGHTING
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-05-04 Cont ID  
Sent By scaldero Date 2015-05-04 Time 14:57 Rev Time 0.00
Received By scaldero Date 2015-05-04 Time 14:57 Sent To  
Notes
2015-05-04 14:59:05PERMIT # 15041132
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 COMMENTS:
 1) VERIFY SUFFICIENT EMERGENCY LIGHTING PROVIDED.
  
 2) FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE SUBMITTED BY EMAIL ([email protected])
 ([email protected]) OR IN WRITING (FAX: 561-804-4774) AND
 APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT
 500 NORTH DIXIE HIGHWAY.
  
 3) PROVIDE 44 INCH WIDE STRIPING (DEMARCATION) IN
 STOREROOM TO ENSURE EGRESS PATH REQUIREMENTS ARE
 MAINTAINED AT ALL TIMES.
  
 4) SUB-PERMITS REQUIRED FOR ALL WORK DONE RELATED TO
 THE FIRE ALARM AND SPRINKLER SYSTEM.
  
 5) WHERE MUSIC SYSTEMS ARE BEING INSTALLED IN TENANT
 SPACES: THE SPEAKER SYSTEM WILL NEED TO BE TESTED
 AGAINST THE FIRE ALARM SYSTEM TO ENSURE THAT THE
 MINIMUM REQUIRED DECIBEL LEVELS OF THE FIRE ALARM
 SYSTEM ARE BEING MET. PENDING RESULTS OF FIELD
 INSPECTION/FIRE ALARM TEST, ADDITIONAL REQUIREMENTS MAY
 BE NEEDED.
  
  
 SUE ELLEN CALDERON
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 644-7326
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-21 Cont ID  
Sent By   Date 2015-07-21 Time   Rev Time 0.00
Received By rmcdouga Date 2015-06-17 Time 10:49 Sent To  
Notes
2015-06-18 11:07:30B38

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-06-03 Cont ID  
Sent By   Date 2015-06-03 Time   Rev Time 0.00
Received By shill Date 2015-04-30 Time 12:21 Sent To  
Notes
2015-04-30 12:26:53B21
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2015-05-01 Cont ID  
Sent By   Date 2015-05-01 Time   Rev Time  
Received By   Date 2015-05-01 Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2015-05-31 Cont ID  
Sent By dhayes Date 2015-05-31 Time 04:49 Rev Time 0.00
Received By tklarge Date 2015-05-31 Time 04:27 Sent To E
Notes
2015-06-03 12:34:56TO D. HAYES DESK FOR ELECTRICAL REVIEW

Review Stop Z ZONING
Rev No 2 Status P Date 2015-07-21 Cont ID  
Sent By eschneid Date 2015-07-21 Time 15:58 Rev Time 0.75
Received By eschneid Date 2015-07-14 Time 16:06 Sent To  
Notes
2015-07-21 15:59:17REDUCED SET OF PLANS WITH LANDLORD STAMP PROVIDED.
2015-07-14 16:06:56LANDLORD STAMP NOT ON THE PLANS
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.

Review Stop Z ZONING
Rev No 1 Status F Date 2015-05-21 Cont ID  
Sent By eschneid Date 2015-05-21 Time 09:17 Rev Time 0.25
Received By eschneid Date 2015-05-21 Time 09:17 Sent To  
Notes
2015-05-21 09:19:06FAILED
  
 ZONING REVIEW WILL REMAIN AS FAIL UNTIL THE PLANS HAVE
 THE LANDLORD APPROVAL STAMP (OR LETTER).
  
 THE PLANS COMPLY WITH ZONING REQUIREMENTS AND HAVE BEEN
 STAMPED "APPROVED".