Plan Review Details - Permit 15041044
| Plan Review Stops For Permit 15041044 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-05-09 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-05-09 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-05-09 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2015-05-09 12:52:55 | SMOKE DETECTORS REQUIRED. FBC-RESIDENTIAL 314 AND 315. | | | VERIFIED BY CONTRACTOR VIA EMAIL. SEE ATTACHED TO PLAN. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-05-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-05-04 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-05-04 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2015-05-04 13:15:59 | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW | | | COMMENTS: | | | | | | 1) INDICATE THE SIZE OF THE EXISTING MAIN BREAKER | | | PROVIDING THE OVERCURRENT PROTECTION TO THE FEEDER TO | | | THE NEW PANEL IN COMPLIANCE WITH THE NEC 408.30 | | | ALL PANELBOARDS SHALL HAVE A RATING NOT LESS THAN THE | | | MINIMUM FEEDER CAPACITY REQUIRED FOR THE LOAD | | | CALCULATED IN ACCORDANCE WITH PARTS II, III, IV, OR V | | | OF ARTICLE 220 AS APPLICABLE. | | | | | | 2) VERIFY OR INSTALL INTERCONNECTED SMOKE DETECTORS IN | | | COMPLIANCE WITH THE FBC-R 314-315. | | | WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL | | | 314 AND 315. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-05-09 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-05-09 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-05-09 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-05-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-05-04 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-04-28 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2015-04-28 12:43:39 | <5000 ELEC |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |